DOWNLOAD Sony DCR-TRV340 Service Manual ↓ Size: 11.4 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV340
Pages
127
Size
11.4 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / BRAZIL
File
dcr-trv340.pdf
Date

Sony DCR-TRV340 Service Manual ▷ View online

5-42
DCR-TRV340
3-3.
SERVO AND RF SYSTEM ADJUSTMENT
Before perform the servo and RF system adjustments, check that
the specified value of “27 MHz Origin Oscillation Adjustment” of
“VIDEO SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Adjusting Procedure:
1.
REEL FG adjustment
2.
PLL f
0
 & LPF f
0
 adjustment
3.
Switching position adjustment
4.
AGC center level and APC & AEQ adjustment
5.
PLL f
0
 & LPF f
0
 fine adjustment
6.
Hi8/Standrd8 switching position adjustment
7.
Cap FG duty adjustment
1. REEL FG Adjustment (VC-276 board)
Compensates the dispersion of the hall elements.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
17, 2F
Specified Value
00 or 01 or 04 or 05
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
0
01
01
Set the data.
3
3
01
1C
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”,
5
3
03
Check that the data is “00” or “01”
or “04” or “05”. (Note)
6
0
01
00
Set the data.
Note:
If the data is other value, adjustment has errors. (Take an appropriate
remedial measures according to the errors referring to the following
table.)
Data
Contents of defect
02, 03, 06, 07
T reel is defective
08, 09, 0C, 0D
S reel is defective
0A, 0B, 0E, 0F
S reel and T reel are defective
2. PLL f
0
 & LPF f
0
 Adjustment (VC-276 board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
21
CA
Set the data, and press PAUSE
button.
3
3
01
00
Set the data, and press PAUSE
button.
4
3
01
30
Set the data, and press PAUSE
button.
5
3
02
Check that the data changes to
“00” with in 10 sec. (Note2)
6
3
03
Check that the data is “00”.
(Note2)
7
0
01
00
Set the data.
Note2:
If it isn’t satisfied, select page: C, address: 21, set the following
data, and press the PAUSE button, and repeat steps 3 to 6.
Setting data
When the data of page: C, address: 21 is “CA”.
CE
When the data of page: C, address: 21 is “CE”.
C6
When the data of page: C, address: 21 is “C6”.
D2
When the data of page: C, address: 21 is “D2”
C2
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
There are errors when it isn’t satisfied even if the above treatment is
done.
If bit2, bit3, bit4, bit5 or bit 6 of the data of page: 3, address: 03 is
“1”, there are errors. For the error contents, see the following table.
(For the bit values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.)
Bit value of page: 3,
Error contents
address: 03 data
bit 2 = 1 or bit 3 = 1
PLL f
0
 fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
 adjustment is defective
bit 6 = 1
LPF f
0
 adjustment is defective
5-43
DCR-TRV340
3. Switching Position Adjustment (VC-276 board)
To obtain normal playback waveform output during the Digital8
playback mode, adjust the switching position.
Mode
VTR playback
Signal
SW/OL reference tape (WR5-2D)
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
10, 11, 12, 13
Specified Value
00
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Insert the SW/OL reference tape
and enter the VTR STOP mode.
2
0
01
01
Set the data.
3
C
10
EE
Set the data, and press PAUSE
button.
4
3
21
Check that the data is “02”.
(Note2)
5
3
01
0D
Set the data, and press PAUSE
button.
6
3
02
Check that the data changes to
“00” in the following order.
“0E”
“29”
“0E”
“20”
“00”
7
3
03
Check that the data is “00”.
(Note3)
8
C
10
Check that the data is other than
“EE”. (Note4)
9
0
01
00
Set the data.
Note2:
If the data of page: 3, address: 21 is “72”, the tape top being played.
After playing the tape for 1 to 2 seconds, stop it, perform step 5
and higher.
Note3:
If the data is other value, adjustment has errors. If bit 0 of the data
is “1”, the A channel is defective. If bit 1 is “1”, the B channel is
defective. Contents of the defect is written into page: C, addresses:
10 and 12. See the following table. (For the bit values, refer to “5-
4. SERVICE MODE”, “4-3. 3. Bit value discrimination”. ) If bit 3
of the data is “1”,the tape end being played, and adjustment has
errors.
Note4:
If the data is “EE”, rewind the tape and repeat steps 1 to 7.
When the A channel is defective
Data of page: C,
Contents of defect
address: 10
EE
Writing into EEPROM (IC4502) is
defective
E8
Adjustment data is out of range
E7
No data is returned from IC3301
When the B channel is defective
Data of page: C,
Contents of defect
address: 12
E8
Adjustment data is out of range
E7
No data is returned from IC3301
4. AGC Center Level and APC & AEQ Adjustment
Note:
The data of page: 0, address: 10 must be “00”.
Use a Hi8 MP tape.
4-1. Preparations before adjustments
Mode
Camera recording
Subject
Arbitrary
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
8
21
C8
Set the data.
3
Record the camera signal for three
minutes.
4-2. AGC Center Level Adjustment (VC-276 board)
Mode
Playback
Signal
Recorded signal at “Preparations before
adjustments”
Measurement Point
Pin qh of CN1108 (RF MON) (Note 1)
Ext. trigger: Pin qd of CN1108 (RF
SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1E
Specified Value
The data of page: 3, address: 03 is “00”
Note 1:
Connect a 75
 resistor between Pin qh and Pin w; (GND) of
CN1108.
75
 resistor (Parts code: 1-247-804-11)
Adjusting method:
Order Page Address Data
Procedure
1
Playback the recorded signal at
“Preparations before adjustments”
2
0
01
01
Set the data.
3
<2>
<4D>
<40> Set the data. (Note2)
[7]
[62]
[01]
4
3
33
08
Set the data.
5
Confirm that the playback RF
signal is stable. (Fig. 5-3-4.)
6
3
01
23
Set the data, and press PAUSE
button.
7
3
02
Check that the data is “00”.
8
3
03
Check that the data is “00”.
(Note3)
9
Perform “APC & AEQ Adjustment”.
Note 2:
< >: DCR-TRV240, [  ]: DCR-TRV340
Note 3:
If the data of page: 3, address: 03 is other than “00”, adjustment
has errors.
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
5-44
DCR-TRV340
4-3. APC & AEQ Adjustment (VC-276 board)
Mode
Playback
Signal
Recorded signal at “Preparations
before adjustments”
Measurement Point
Pin qh of CN1108 (RF MON) (Note 1)
Ext. trigger: Pin qd of CN1108 (RF
SWP)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
18, 19, 1B, 1C, 21, 2C
Specified Value
The data of page: 3, address: 03 is “00”
Note 1:
Connect a 75
 resistor between Pin qh and Pin w; (GND) of
CN1108.
75
 resistor (Parts code: 1-247-804-11)
Note 2:
The  “AGC Center Level Adjustment” must have already been
completed before starting this adjustment.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
18
20
Set the data, and press PAUSE
button.
3
C
19
20
Set the data, and press PAUSE
button.
4
C
1B
25
Set the data, and press PAUSE
button.
5
C
1C
25
Set the data, and press PAUSE
button.
6
C
21
CA
Set the data, and press PAUSE
button.
7
C
2C
03
Set the data, and press PAUSE
button.
8
Playback the recorded signal at
“Preparations before adjustments”
9
<2>
<4D>
<40> Set the data. (Note3)
[7]
[62]
[01]
10
3
33
08
Set the data.
11
Confirm that the playback RF
signal is stable. (Fig. 5-3-4.)
12
3
01
07
Set the data, and press PAUSE
button.
13
3
02
Check that the data changes from
“07” to “00” in about 20 seconds
after pressing PAUSE button.
14
3
03
Check that the data is “00”.
(Note4)
15
Perform “Processing after
Completing Adjustments”.
Note 3:
< >: DCR-TRV240, [  ]: DCR-TRV340
Note 4:
If the data is other than “00”, adjustment has errors.
4-4. Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
<2>
<4D>
<00> Set the data. (Note)
[7]
[62]
[00]
3
3
33
00
Set the data.
4
8
21
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
Note:
< >: DCR-TRV240, [  ]: DCR-TRV340
Fig. 5-3-4.
RadarW
RadarW
RadarW
RadarW
RadarW
RadarW
13.3 msec 
PB RF signal is stable
Pin 
qd
Pin 
qh
5-45
DCR-TRV340
5. PLL f
0
 & LPF f
0
 Fine Adjustment (VC-276 board)
Mode
VTR stop
Signal
Arbitrary
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Display data of page: 3, address: 02 is
“00”.
Display data of page: 3, address: 03 is
“00”.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
01
30
Set the data, and press PAUSE
button.
3
3
02
Check that the data changes to
“00” with in 10 sec. (Note2)
4
3
03
Check that the data is “00”.
(Note3)
5
0
01
00
Set the data.
Note2:
If it isn’t satisfied, there are errors.
Note3:
If the data of page: 3, address: 03 is other than “00”, there are
errors. For the error contents, see the following table. (For the bit
values, refer to “5-4. SERVICE MODE”,  “4-3. 3. Bit value
discrimination”.)
6. Hi8/Standard8 Switching Position Adjustment
(VC-276 board)
If deviated in this case causes switching noise or jitter on the Hi8/
Standard8 mode played back screen.
Mode
Playback
Signal
Hi8/Standard8 alignment tape:
  For tracking adjustment (WR5-1NP)
Measurement Point
CH1: Pin 8 of CN1108 (RF SWP)
CH2: Pin 5 of CN1108 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
40, 41
Specified Value
t1 = 0 ± 10 
µ
sec
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting Method:
Order Page Address Data
Procedure
1
Set to the stop mode.
2
0
01
01
Set the data.
3
C
3E
40
Set the data, and press PAUSE
button.
4
<2>
<4D>
<80> Set the data. (Note2)
[7]
[62]
[02]
5
Set to the playback mode.
6
C
40
Change the data and minimize
“t1”. (Coarse adjustment)
7
C
40
Press PAUSE button
8
C
41
Change the data and adjust so that
the switching position (t1)
becomes the specified value. (Fine
adjustment)
9
C
41
Press PAUSE button
10
C
3E
00
Set the data, and press PAUSE
button.
11
<2>
<4D>
<00> Set the data. (Note2)
[7]
[62]
[00]
12
0
01
00
Set the data.
Note2:
< >: DCR-TRV240, [  ]: DCR-TRV340
RadarW
RadarW
RadarW
Fig. 5-3-5.
CH1
CH2
Enlargement
t1=0 
±
 10 
µ
sec
CH1
CH2
Bit value of page: 3,
Error contents
address: 03
bit 2 = 1 or bit 3 = 1
PLL f
0
 fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
 adjustment is defective
bit 6 = 1
LPF f
0
 adjustment is defective