5-28
9. Auto White Balance Standard Data Input
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
32 to 35
Note 1:
This adjustment should be carried out upon completion of “6. Color
Reproduction Adjustment”.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If not, select
page: 6, address: 01, set data: 00, and press the PAUSE button of
the adjustment remote commander.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Wait for 2 seconds.
3)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button.
(When the standard data is take in, the data will be automatically
input to page: F, address: 32 to 35.)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Perform “Auto White Balance Adjustment”.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
10. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note2)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
54, 55
Specified Value
720H model
R ratio: 2BC0 to 2C40
B ratio: 5F40 to 5FC0
960H model
R ratio: 2C40 to 2CC0
B ratio: 5D40 to 5DC0
Note 1:
Perform “Auto White Balance Standard Data Input” before this
adjustment.
Note 2:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Note 3:
720H model:DCR-TR7000/TRV103/TRV110/TRV110P/
TRV203/TRV210/TRV310/TRV310P/TRV315
960H model: DCR-TR7000E/TR7100E/TRV110E/TRV210E/
TRV310E
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Place the C14 filter for color temperature correction on the lens.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: E, address: 88 to 8B, and note down the data of
each address.
4)
Input the following data to page: E, addresses:88 to 8B.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
5)
Select page: 6, address: 01, set data: A7, and press the PAUSE button.
6)
Select page: 6, address: 01, set data: A5, and press the PAUSE button.
(The auto white balance adjustment is performed and the
adjustment data is stored in page: F, address: 54 and 55.)
7)
Select page: 6, address: 02, and check that the data is “01”.
8)
Select page: 6, address: 01, set data: 3F, and press the PAUSE button.
9)
Select page: 0, address: 03, and set data: 04.
10) Select page: 1, and check that the display data (Note2) satisfies
the R ratio specified value.
11) Select page: 0, address: 03, and set data: 05.
12) Select page: 1, and check that the display data (Note2) satisfies
the B ratio specified value.
13) Select page: E, address: 88 to 8B, and input the data noted
down at step 3).
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Select page: 0, address: 03, and set data: 00.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Address
Data
720H model
960H model
88
2C
2C
89
00
80
8A
5F
5D
8B
80
80
5-29
R-Y
2mm
B-Y
2mm
R-Y
B-Y
1.0mm
1.0mm
3mm
3mm
R-Y
B-Y
3mm
3mm
2.0mm
1.0mm
Fig. 5-1-13. (A)
Fig. 5-1-13. (B)
Fig. 5-1-13. (C)
11. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-13. A to C
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Checking method:
1)
Check that the lens is not covered with either filter.
2)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
3)
Check that the center of the white luminance point is within
the circle shown Fig. 5-1-13. (A).
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 01, set data: 23, and press the PAUSE
button.
6)
Place the C14 filter on the lens.
7)
Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-13. (B).
8)
Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3)
on the lens.
9)
Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
10) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-13. (C).
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5-30
12. Angular Velocity Sensor Sensitivity Data check
• This adjustment is performed only when replacing the angular
velocity sensor.
Although this adjustment need not be performed when the circuit
is damaged, etc., check the operations.
• Note down the sensitivity displayed on the angular velocity sensor
of the repair parts. At this time, note down also to which board it
was attached to.
Be sure to check because if attached incorrectly, the screen will
vibrate up and down or left and right during hand-shake correction
operations.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03JA
Type B
ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment Page
F
Adjustment Address
5F, 60
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 5F and check that the data is “82”.
3)
Select page: F, address: 60 and check that the data is “80”.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Check that the steady shot operations have been performed
normally.
Ver 1.3  2001. 01
5-31
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENTS
(DCR-TR7000/TR7000E/TR7100E/TRV315)
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN910 of the VC-213 board.
Connect the Measuring Instruments via the CPC-13 jig (J-6082-
443-A).
The following table shows the Pin No. and signal name of CN910.
Table 5-1-9.
1. EVF Initial Data Input
Mode
Camera
Subject
Arbitrary
Adjustment Page
D
Adjustment Address
70 to 76, 78 to 7C
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
3)
Select page: 0, address: 01, and set data: 00.
Pin No.
1
2
3
4
5
6
7
8
9
10
Signal Name
SWP
AFC F0
BPF MONI
RF AGC IN
PB RF
REG GND
RF AGC OUT
VC RF SWP
EVF BL
EVF BL 4.6V
Pin No.
11
12
13
14
15
16
17
18
19
20
Signal Name
EVF VCO
EVF VG
DV RF SWP
RF IN
CAP FG
RF MON
TMS
TCK
TDO
TDI
Address
70
71
72
73
74
75
76
78
79
7A
7B
7C
Data
7A
90
60
48
5A
70
B0
D1
AC
60
70
90
Remark
Fixed data
White balance adj.
White balance adj.
Fixed data
Fixed data
VCO adj.
Backlight consumption current adj.
Fixed data
Fixed data
Bright adj.
Contrast adj.
Backlight consumption current adj.
CN910
1
20
Screw driver (–)
Cover
Fig. 5-1-14