DOWNLOAD Sony DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 Service Manual ↓ Size: 40.54 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TR7000 DCR-TR7000E DCR-TR7100E DCR-TRV103 DCR-TRV110 DCR-TRV110E DCR-TRV110P DCR-TRV203 DCR-TRV210 DCR-TRV210E DCR-TRV310 DCR-TRV310E DCR-TRV310P DCR-TRV315
Pages
127
Size
40.54 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
dcr-tr7000-dcr-tr7000e-dcr-tr7100e-dcr-trv103-dcr-.pdf
Date

Sony DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 Service Manual ▷ View online

5-12
Address
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
Remark
Fixed data-2
Fixed data-1
(Initialized data)
Initial
NTSC
 value
PAL
Table. 5-1-2.
1-2-2. INITIALIZATION OF D PAGE DATA
1. Initializing the D Page Data
Note:
If the D Page data has been initialized, “Modification of D Page
Data” and following adjustments need to be performed again.
1)
Color viewfinder system adjustments
2)
LCD system adjustments
3)
Battery end adjustments
Adjusting page
D
Adjusting Address
10 to 8F
Initializing Method:
1)
Select page: 0, address: 01, and set data: 80.
2)
Select page: 3, address: 80, set data: 0D, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 80, and check that the data changes to
“1D”.
4)
Select page: 0, address: 01, and set data: 00.
5)
Perform “Modification of D Page Data”.
2. Modification of D Page Data
If the D Page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
Note:
If the following symptoms occur after completing of the
“Modification of D page data” check that the data of the “Fixed
data-2” addresses are model of the same destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is short off so that unit cannot operate.
3. D Page Table
Note 1:
Fixed data-1 : Initialized data. (Refer to “1. Initializing the D Page
Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of D Page
Data”.)
Address
00 to 0F
10
11
12
13
14
15
16
17
Initial
NTSC
00
Remark
Test mode
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
 value
PAL
00
5-13
Address
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49
4A
4B
Initial
NTSC
90
98
AC
B2
BA
Remark
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Battery end adj.
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Address
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
 value
PAL
90
98
AC
B2
BA
Initial
NTSC
90
60
70
B0
60
70
90
 value
PAL
90
60
70
B0
60
70
90
Remark
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
White balance adj. (EVF)
Fixed data-1
Fixed data-2
VCO adj. (EVF)
Backlight consumption current adj.
(EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Bright adj. (EVF)
Contrast adj. (EVF)
Backlight consumption current adj.
(EVF)
Fixed data-1
(Initialized data)
5-14
Note 2:
LCD TYPE S / LCD TYPE C
LCD TYPE S model:DCR-TRV103/TRV110/TRV110E/
 TRV110P/TRV203/TRV210/TRV210E/
 TRV310E/TRV315
LCD TYPE C model: DCR-TRV310/TRV310P
Table. 5-1-3.
Address
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
Remark
White balance adj. (LCD) (Note2)
White balance adj. (LCD) (Note2)
D range adj. (LCD) (Note2)
V-COM level adj. (LCD) (Note2)
VCO adj. (LCD)
V-COM adj. (LCD) (Note2)
Fixed data-1
Bright adj. (LCD) (Note2)
Color adj. (LCD)
Contrast adj. (LCD) (Note2)
Fixed data-1
(Initialized data)
Initial
NTSC
80/98
80/7B
88/80
90/89
80
70/80
60/84
78
80/8D
 value
PAL
80/98
80/7B
88/80
90/89
80
70/80
60/84
78
80/8D
5-15
1-2-3. INITIALIZATION OF E, F PAGE DATA
1. Initializing the E, F Page Data
Note:
If the E, F page data has been initialized, “Modification of E, F
Page Data” and following adjustments need to be performed again.
1)
Camera system adjustments
2)
“Hi8/standard 8 mm switching position adjustment” and “CAP
FG offset adjustment” of the servo & RF system adjustments
3)
Video system adjustments
4)
IR transmitter adjustments
5)
Audio system adjustments
Adjusting Page
F
Adjusting Address
00 to FF
Adjusting Page
E
Adjusting Address
00 to FF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 80.
2)
Select page: 6, address: 00, and set data: 55 (NTSC) or data:
51 (PAL).
3)
Select page: 6, address: 01, set data: 55 (NTSC) or data: 51
(PAL), and press the PAUSE button of the adjustment remote
commander.
4)
Select page: 6, address: 02, and check that the data is “01”.
5)
Select page: 0, address: 01, and set data: 00.
6)
Perform “Modification of E, F Page Data”.
2. Modification of E, F Page Data
If the E, F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of F, E Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. F Page table
Note:
Fixed data-1 : Initialized data. (Refer to “1. Initializing the E, F
Page Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of E, F
Page Data”.)
Address
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
Initial
NTSC
00
00
00
00
00
00
00
00
00
00
00
00
43
3F
AB
4B
2B
00
54
00
1C
03
25
24
11
05
0A
00
A0
Remark
Emergency memory address
Fixed data-2
Fixed data-1
(Initialized data)
AGC gain calibration adj.
AWB standard data input
Fixed data-1
(Initialized data)
Flange back adj.
Hi8/standard 8 mm switching
position adj.
27MHz/36MHz origin oscillation adj.
 value
PAL
00
00
00
00
00
00
00
00
00
00
00
00
43
3F
AB
4B
2B
00
54
00
1C
03
25
24
11
05
0A
00
A0
Page of 127
Display