DOWNLOAD Sony DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 Service Manual ↓ Size: 40.54 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TR7000 DCR-TR7000E DCR-TR7100E DCR-TRV103 DCR-TRV110 DCR-TRV110E DCR-TRV110P DCR-TRV203 DCR-TRV210 DCR-TRV210E DCR-TRV310 DCR-TRV310E DCR-TRV310P DCR-TRV315
Pages
127
Size
40.54 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
dcr-tr7000-dcr-tr7000e-dcr-tr7100e-dcr-trv103-dcr-.pdf
Date

Sony DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 Service Manual ▷ View online

5-20
Address
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
Remark
Fixed data-1
(Initialized data)
Table. 5-1-5.
5-21
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, Check that the
specified values of “27/36MHz Origin Oscillation Adjustment”, “S
VIDEO OUT Y level Adjustment” and “S VIDEO OUT C level
Adjustment” of “VIDEO SYSTEM ADJUSTMENT” are satisfied.
1. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
Display data of page 1
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
47, 48
Specified Value
88 to 8C during IRIS OPEN
15 to 19 during IRIS CLOSE
Note:
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Display data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 47 and 48.)
3)
Select page: 6, address: 02, and check that the data is “01”.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1)
Select page: 0, address: 03, and set data: 03.
2)
Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
3)
Select page: 1, and check that the display data (Note) during
IRIS OPEN satisfies the specified value.
4)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5)
Select page: 1, and check that the display data during IRIS
CLOSE satisfies the specified value.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
5-22
2. Flange Back Adjustment
    (Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note 1)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
38 to 3D, 5A to 5E, F8 to FA
Note 1:
Dark Siemens star chart.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Preparation for adjustment
The minipattern box is installed as shown in the following figure.
Note :
The attachment lenses are not used.
Specified voltage:
The specified voltage varies according to the
minipattern box, so adjust the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the
minipattern box.
Address
38
39
3A
3B
3C
3D
5A
Data
1C
03
25
24
11
05
2A
Address
5B
5C
5D
5E
F8
F9
FA
Data
00
19
00
37
00
00
00
Adjusting method:
1)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 5 cm.
2)
Make the height of the minipattern box and the camcorder equal.
3)
Check that the output voltage of the regulated power supply is
the specified voltage ± 0.01Vdc.
4)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
5)
Select page: 0, address: 01, and set data: 01.
6)
Check that the data of page: F, address:38 to 3D, 5A to 5E, F8
to FA is the initial value (See table below).
7)
Select page: 6, address: 02, and check that the data is “00”.
8)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
9)
Select page: 6, address: 01, set data: 27, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:38 to 3D, 5A to 5E, F8 to FA.)
10) Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Select page: 0, address:01, and set data: 00.
2)
Turn OFF the main power supply (8.4V).
3)
Perform “Flange Back Check”.
Minipattern box
Below 5 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Fig. 5-1-8.
Ver 1.1    1999. 06
5-23
3. Flange Back Adjustment
    (Using Flange Back Adjustment Chart Subject More
      Than 500 m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
3-1. Flange Back Adjustment(1)
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 350 ± 50 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
38 to 3D, 5A to 5E, F8 to FA
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
2)
Select page: 0, address: 01, and set data: 01.
3)
Check that the data of page: F, address:38 to 3D, 5A to 5E, F8
to FA is the initial value (See table below).
4)
Select page: 6, address: 02, and check that the data is “00”.
5)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 6, address: 01, set data: 15, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:38 to 3D, 5A to 5E, F8 to FA.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Turn OFF the main power supply (8.4V).
2)
Perform “Flange Back Adjustment (2)”.
Address
38
39
3A
3B
3C
3D
5A
Data
1C
03
25
24
11
05
2A
Address
5B
5C
5D
5E
F8
F9
FA
Data
00
19
00
37
00
00
00
3-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
38 to 3D, 5A to 5E, F8 to FA
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 02, and check that the data is “00”.
4)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
5)
Place a ND filter on the lens so that the optimum image is
obtain.
6)
Select page: 6, address: 01, set data: 29, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:38 to 3D, 5A to 5E, F8 to FA.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn OFF the main power supply (8.4V).
3)
Perform “Flange Back Check”.
Page of 127
Display

Click on the first or last page to see other DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 service manuals if exist.