DOWNLOAD Sony DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 Service Manual ↓ Size: 40.54 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TR7000 DCR-TR7000E DCR-TR7100E DCR-TRV103 DCR-TRV110 DCR-TRV110E DCR-TRV110P DCR-TRV203 DCR-TRV210 DCR-TRV210E DCR-TRV310 DCR-TRV310E DCR-TRV310P DCR-TRV315
Pages
127
Size
40.54 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
dcr-tr7000-dcr-tr7000e-dcr-tr7100e-dcr-trv103-dcr-.pdf
Date

Sony DCR-TR7000 / DCR-TR7000E / DCR-TR7100E / DCR-TRV103 / DCR-TRV110 / DCR-TRV110E / DCR-TRV110P / DCR-TRV203 / DCR-TRV210 / DCR-TRV210E / DCR-TRV310 / DCR-TRV310E / DCR-TRV310P / DCR-TRV315 Service Manual ▷ View online

5-24
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-9.
2. Vertical period
Fig. 5-1-10.
Check on the monitor TV (Underscanned mode)
Fig. 5-1-11.
5. Picture Frame Setting
Subject
Color bar chart
(Color reproduction adjustment frame)
(1.5m from the front of the lens)
Measurement Point
Video output terminal
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Setting method:
1)
Adjust the zoom and the camera direction, and set to the
specified position.
2)
Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following
adjustments using “Color reproduction adjustment frame”.
4. Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE end.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Select page: 6, address: 40, and set data: 02.
4)
Select page: 6, address: 41, and set data: 01.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Note: 
When the auto focus is ON, the lens can be checked if it is
focused or not by observing the data on the page 1 of the
adjustment remote commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Processing after Completing Adjustments
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
5-25
6. AGC Gain Calibration Adjustment
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
Display data of page 1 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
2E, 2F, 30, 31
Specified Value
Data1 : 0196 to 0283
Data2  : 0C97 to 13F4
Note:
 Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: 71, and press the PAUSE
button of the adjustment remote commander.
(The AGC gain calibration adjustment is performed and the
adjustment data is stored in page: F, address: 2E to 31.)
3)
Select page: 6, address: 02, and check that the data is “01”.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1)
Select page: 0, address: 03, and set data: 25.
2)
Select page: 6, address: 9A, and set data: 03.
3)
Select page: 6, address: 01, set data: 9B, and press the PAUSE
button.
4)
Select page: 6, address: 02, and check that the data is “01”.
5)
Select page: 1, and check that the display data (Note) satisfies
the specified value of data1.
6)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
7)
Select page: 6, address: 9A, and set data: 99.
8)
Select page: 6, address: 01, set data: 9B, and press the PAUSE
button.
9)
Select page: 6, address: 02, and check that the data is “01”.
10) Select page: 1, and check that the display data (Note) satisfies
the specified value of data2.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, and set data: 00, and press the
PAUSE button.
2)
Select page: 6, address: 9A, and set data: 00.
3)
Select page: 0, address: 01, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.
5-26
Fig. 5-1-12.
7. Color Reproduction Adjustment
Adjust the color Separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment frame)
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
4E, 50, FB, FC
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note:
NTSC 720H model:DCR-TR7000/TRV103/TRV110/TRV110P/
TRV203/TRV210/TRV310/TRV310P/TRV315
PAL 960H model: DCR-TR7000E/TR7100E/TRV110E/TRV210E/
TRV310E
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: E1, set data: 1B, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 27, set data: 3F, and press the PAUSE
button.
4)
Select page: 6, address: 01, set data: 3D, and press the PAUSE
button.
5)
Adjust the GAIN and PHASE of the vectorscope, and adjust
the burst luminance point to the burst position of the color
reproduction frame.
6)
Change the data of page: F, address: 4E, 50, FB and FC, and
settle each color luminance point in each color reproduction
frame.
Note:
Be sure to press the PAUSE button of the adjustment remote
commander before changing the addresses. If not, the new data
will not be written to the memory.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: F, address: E1, set data: 20, and press the PAUSE
button.
3)
Select page: 0, address: 01, and set data: 00.
PAL 960H model
Burst position
Burst position
NTSC 720H model
5-27
8. IRIS IN/OUT Adjustment
For the unit to judge if the white balance is indoors or outdoors in
auto white balance operations, measure the light level and write it
in the EEPROM.
If the level is not correct, the white balance will not be accurate.
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
DDS display of EVF or LCD or TV
monitor (Note)
Measuring Instrument
Adjustment Page
F
Adjustment Address
56, 57
Note:
The right four digits of the DDS display data of EVF or LCD or TV
monitor.
CAM  00  00 00
CAM  00  XX XX
Lower two digits
Upper two digits
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 0, address: 03, and set data: 06.
3)
Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 40, and set data: 02.
5)
Select page: 6, address: 01, set data: 0B, and press the PAUSE
button.
6)
Read the DDS display data (Note), and take the upper two digits
as D
1
 and the lower two as D
2
.
7)
Convert D
1
 to decimal notation, and obtain D
1
'. (Refer to Table
5-4-1. “Hexadecimal - decimal conversion table” of “5-4.
Service Mode”.)
8)
Calculate D
3
' using the following equations. (Equations 1 and
2 are for decimal notation calculation).
When  D
2
   D0
D
3
' = D
1
' – 21
Equation 1
When  D
2
 < D0
D
3
' = D
1
' – 22
Equation 2
9)
Convert D
3
' to hexadecimal notation, and obtain D
3
.
10) Select page: F, address: 56, set data: D
3
, and press the PAUSE
button.
11) Select page: 6, address: 01, set data: 09, and press the PAUSE
button.
12) Read the DDS display data (Note), and take the upper two digits
as D
4
 and the lower two as D
5
.
13) Convert D
4
 to decimal notation, and obtain D
4
'. (Refer to Table
5-4-1. “Hexadecimal - decimal conversion table” of “5-4.
Service Mode”.)
14) Calculate D
6
' using the following equations.  (Equations 3 and
4 are for decimal notation calculation).
When  D
5
   F0
D
6
' = D
4
' – 13
Equation 3
When  D
5
 < F0
D
6
' = D
4
' – 14
Equation 4
15) Convert D
6
' to hexadecimal notation, and obtain D
6
.
16) Select page: F, address: 57, set data: D
6
, and press the PAUSE
button.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 40, and set data: 00