6-39
DCR-SR90E/SR100/SR100E_ADJ
13) Upon successful completion of the “10. Color Reproduction
Check”, the following message is displayed. Then, change the
chart in accordance with the message.
14) After the setting, if the [OK] button is clicked, the adjustment
items “11. AWB Check” is executed. During the execution,
the following messages are displayed in the order given be-
low. Place or remove the filters on the lens in accordance with
the messages.
15) Upon completion of “11. AWB Check”, the following mes-
sage is displayed during the execution of “12. Picture Frame
Setting (Center Frame)”. Set the subject in accordance with
the message, and then check the size of clear chart shot on the
monitor screen.
16) After the checking, if the [OK] button in the message window
is clicked, “13. MAX GAIN Adj.” and “14. Mechanical Shut-
ter Adj.” are executed.
17) Upon successful completion of the “14. Mechanical Shutter
Adj.”, “15. Release of Data Setting during Camera Adj.” is
executed.
18) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
12) If the [OK] button is clicked, the adjustment items “9. Color
Reproduction Adj.” and “10. Color Reproduction Check” are
executed. The following messages are displayed in order, and
then operate the vectorscope to make a check with the color
reproduction frame in accordance with the message.
NTSC model
PAL model
Fig. 6-1-16
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
Burst position
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
6-40
DCR-SR90E/SR100/SR100E_ADJ
8.
CAMERA Adjustment 5
Note: “CAMERA Adjustment 5” is available only once after the
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Strobe Light Level Adj.
3. Strobe White Balance Adj.
4. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 5.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “4. Preparing the Flash
Adjustment Box” (see page 6-10).)
4) Press the [OK]  button, and the items “2. Strobe Light Level
Adj.” and “3. Strobe White Balance Adj.” will be executed.
5) Upon completion of “3. Strobe White Balance Adj.”, “4. Re-
lease of Data Setting during Camera Adj.” is executed
6) Upon successful completion of all items of the CAMERA Ad-
justment 5, the following message is displayed. Click the [OK]
button.
How to reset the flash error flag
When the flash error code (E:91: ** ) is displayed. After repair,
clear the error flag in the following method.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data is “01”.
9.
CAMERA Adjustment 6
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Steady Shot Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed.
With the camcorder in stationary state, click the [OK] button.
4) If the [OK] button is clicked, “2. Steady Shot Check” is ex-
ecuted.
Upon successful completion of the “2. Steady Shot Check”,
the following message is displayed. Check that the steadyshot
function operates normally in accordance with the message.
5) If the [OK] button is clicked, “3. Release of Data Setting dur-
ing Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 6, the following message is displayed. Click the
[OK] button.
6-41
DCR-SR90E/SR100/SR100E_ADJ
1-8.
LCD/EVF  SYSTEM  ADJUSTMENTS
1.
Function of Each Button on LCD/EVF System Ad-
justment Screen
Click the [LCD/EVF SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “LCD/EVF SYSTEM ADJUSTMENT”
screen in Fig. 6-1-17 will appear.
Fig. 6-1-17
1
[To Menu] button
The Main Menu screen comes back.
2
Model Select radio button
Selects the model to be adjusted.
Note: NTSC model: DCR-SR100
PAL model: DCR-SR90E/SR100E
3
[Start] button
Each adjustment “LCD adjustment” or “EVF Adjustment” or
“Touch Panel Adjustment” starts.
4
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the LCD/EVF ad-
justment. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
2.
Adjustment Items of LCD/EVF System Adjustment
The adjustment items of LCD/EVF system adjustment are as listed
in Table 6-1-4. The Automatic Adjustment Program executes the
adjustment items if the LCD/EVF Adjustment Start button is
clicked.
Table 6-1-4
Button
Name
Adjustment
Page
Address
VCO Adj. (LCD)
0C
50, 51
Contrast Adj. (LCD)
0C
58
V-COM Adj. (LCD)
0C
52
VCO Adj. (EVF)
0C
3F, 40
Contrast Adj. (EVF)
0C
47
White Balance Adj. (EVF)
0C
45, 46
0C
56, 57
0C
7B, 7C
Transmissive Mode White
Balance Adj. (LCD)
Reflective Mode White
Balance Adj. (LCD)
Touch Panel Adj.
0A
90 to 93
LCD
Adjustment
EVF
Adjustment
Touch Panel
Adjustment
4
2
3
1
6-42
DCR-SR90E/SR100/SR100E_ADJ
5) If the [End] button is clicked, the following screen is displayed
during the execution of “4. Transmissive Mode White Balance
Adj.”. Check that the LCD screen is not colored. If colored,
using the [Up]/[Down] button on the screen, adjust so that the
LCD screen is not colored. After the adjustment, click the [End]
button in the screen.
6) If the [End] button is clicked, “5. Reflective Mode White Bal-
ance Adj.” will be executed.
7) Upon successful completion of the “5. Reflective Mode White
Balance Adj.”, “6. Release of Data Setting during LCD/EVF
Adj.” will be executed.
8) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
3.
LCD Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD/EVF Adj.
2. LCD Automatic Adj.
(VCO Adj., Contrast Adj.)
3. V-COM Adj.
4. Transmissive Mode White Balance Adj.
5. Reflective Mode White Balance Adj.
6. Release of Data Setting during LCD/EVF Adj.
[Adjusting method]
1) Select the model with the Model Select radio button.
Note: NTSC model: DCR-SR100
PAL model: DCR-SR90E/SR100E
2) Click the [Start] button of the LCD Adjustment.
3) The Automatic Adjustment Program executes the “1. Data
Setting during LCD/EVF Adj.” and “2. LCD Automatic Adj.”.
4) After that, the following screen is displayed during the execu-
tion of “3. V-COM Adj.”. Using the [Up]/[Down] button on the
screen, adjust so that the brightness of portions A and B on the
LCD panel is equal. After the adjustment, click the [End] but-
ton in the screen.
Page of 66