DOWNLOAD Sony DCR-SR100 / DCR-SR100E / DCR-SR90E (serv.man4) Service Manual ↓ Size: 1.11 MB | Pages: 66 in PDF or view online for FREE

Model
DCR-SR100 DCR-SR100E DCR-SR90E (serv.man4)
Pages
66
Size
1.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr100-dcr-sr100e-dcr-sr90e-sm4.pdf
Date

Sony DCR-SR100 / DCR-SR100E / DCR-SR90E (serv.man4) Service Manual ▷ View online

6-35
DCR-SR90E/SR100/SR100E_ADJ
5.
CAMERA Adjustment 2
(Using the flange back adjustment chart and sub-
ject more than 500 m away)
5-1. CAMERA Adjustment 2 (1)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (1) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Place the Flange back adjustment chart at 2 m position away
from the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
[Adjusting method]
1) Click the [Start $1%] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back (1) Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 2 (1), the following message is displayed. Click
the [OK] button.
6) Perform “CAMERA Adjustment 2 (2)”.
5-2. CAMERA Adjustment 2 (2)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (2) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
[Adjusting method]
1) Click the [Start $2%] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back (2) Adj.” will be
executed.
The following message is displayed during the execution of
adjustment, and then place the ND filter on the lens so as to
obtain the optimum image.
5) If “2. Flange Back Adj.” completed successfully, “3. Release
of Data Setting during Camera Adj.” will be executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2 (2), the following message is displayed. Click
the [OK] button.
6-36
DCR-SR90E/SR100/SR100E_ADJ
6.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) If the [OK] button is clicked, “2. Flange Back Check” is ex-
ecuted. The following messages are displayed, and then oper-
ate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK] button.
6-37
DCR-SR90E/SR100/SR100E_ADJ
7.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting (Color Reproduction Adjustment Frame)
3. Mixed Color Compensation Adj.
4. F No. & ND Light Quality Standard Data Input
5. Picture Frame Setting (All White Frame)
6. AWB Standard Data Input
7. LV Standard Data Input
8. AWB Adj.
9. Color Reproduction Adj.
10. Color Reproduction Check
11. AWB Check
12. Picture Frame Setting (Center Frame)
13. MAX GAIN Adj.
14. Mechanical Shutter Adj.
15. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Select the model (NTSC Model or PAL Model) with the Model
Select radio button.
Note: NTSC model: DCR- SR100
PAL model: DCR-SR90E/SR100E
2) Click the [Start] button of the CAMERA Adjustment 4.
3) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
4) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following screen is displayed during the ex-
ecution of “2. Picture Frame Setting (Color Reproduction Ad-
justment Frame)”. Set the subject in accordance with the mes-
sage.
5) If the [OK] button is clicked, the following screen will appear,
and then adjust the zoom and the camera direction to set the
picture frame. After the setting finished, click the [End] but-
ton.
The buttons on this screen provide the following functions:
[Save the position] button
Saves the camera zoom and focus position data.
[Load the position] button
Reads the camera zoom and focus position data saved last and
moves the camera zoom and focus to that position.
Note 1: The zoom and focus position data are saved with
“DCR_SR100_ZoomFocusData.txt” file name in the
same holder as the Automatic Adjustment Program.
No position data can be read if this file is moved or de-
leted.
Note 2: Only the latest position data can be saved. If the [Save the
position] button is clicked, the latest data are saved over-
writing the previous data.
6-38
DCR-SR90E/SR100/SR100E_ADJ
10) After the setting, if the [OK] button is clicked, the adjustment
items from “6. AWB Standard Data Input” to “8. AWB Adj.”
are executed. During the execution, the following messages
are displayed in the order given below. Place or remove the
filters on the lens in accordance with the messages.
11) Upon successful completion of the “8. AWB Adj.”, the follow-
ing message is displayed. Then, change the chart in accordance
with the message.
6) After setting the picture frame, if the [End] button is clicked,
the following message is displayed. Then, change the chart in
accordance with the message.
7) If the [OK] button is clicked, the adjustment items “3. Mixed
Color Compensation Adj.” and “4. F No. & ND Light Quality
Standard Data Input” are executed.
8) Upon successful completion of the “4. F No. & ND Light Qual-
ity Standard Data Input”, the following message is displayed.
Then, change the chart in accordance with the message.
9) If the [OK] button is clicked, “5. Picture Frame Setting (All
White Frame)” is executed. The following messages are dis-
played in the order given below during the execution. Then,
set the picture frame in accordance with the messages.