DOWNLOAD Sony DCR-SR100 / DCR-SR100E / DCR-SR90E (serv.man4) Service Manual ↓ Size: 1.11 MB | Pages: 66 in PDF or view online for FREE

Model
DCR-SR100 DCR-SR100E DCR-SR90E (serv.man4)
Pages
66
Size
1.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr100-dcr-sr100e-dcr-sr90e-sm4.pdf
Date

Sony DCR-SR100 / DCR-SR100E / DCR-SR90E (serv.man4) Service Manual ▷ View online

6-15
DCR-SR90E/SR100/SR100E_ADJ
2.
Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 14, 19, 1E, 1F, set data: 01 to
page: 0, address: 10, and then select pages 4, 9, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification E, F, 14, 19, 1E,
1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
Note 2: This operation should be done with the adjustment re-
mote commander. The operation of page: 02 cannot be
performed with the SeusCam.
1-2-2.
Initialization of E, F, 14, 19, 1E, 1F Page Data
1.
Initializing of E, F, 14, 19, 1E, 1F Page Data
Note 1: If “Initialization of Pages E, F, 14, 19, 1E, 1F” is ex-
ecuted, all data on pages E, F, 14, 19, 1E, 1F are initial-
ized. (Only an individual page cannot be initialized)
Note 2: If the E, F, 14, 19, 1E, 1F page data has been initialized,
the following adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustment
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
14
Adjustment Address
00 to FF
Adjustment Page
19
Adjustment Address
00 to FF
Adjustment Page
1E
Adjustment Address
00 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE (Write) button.
3
6
01
2D: NTSC model
2F: PAL model
4
6
03
03
Press PAUSE (Write) button.
5
Wait for 6 seconds.
6
6
02
Check the data changes to
“01”.
7
Perform “Modification of E,
F, 14, 19, 1E, 1F Page Data”
Note 3: NTSC model: DCR-SR100
PAL model: DCR-SR90E/SR100E
6-16
DCR-SR90E/SR100/SR100E_ADJ
4.
F Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 12
Fixed data-1 (Initialized data)
13
28
28
14
70
70
15
40
40
16
80
80
17
19
19
HALL adj.
18
28
28
19
D8
D8
1A
28
28
1B
D8
D8
1C
00
00
1D
00
00
1E
00
00
1F
00
00
20
00
00
21
00
00
22
00
00
F No. & ND light quality standard
23
00
00
data input
24
D0
D0
25
C8
C8
26
E0
E0
27
28
28
28
00
00
29
00
00
2A
35
35
2B
00
00
LV standard data input
2C
68
78
Max gain adj.
2D
Fixed data-1 (Initialized data)
2E
1A
1A
2F
00
00
30
07
07
AWB standard data input
31
00
00
32
11
11
33
00
00
AWB adj.
34
0A
0A
35
00
00
36 to 3D
Fixed data-1 (Initialized data)
3E
2D
2D
3F
64
64
Strobe white balance adj.
40 to 43
Fixed data-1 (Initialized data)
3.
E Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 04
Fixed data-1 (Initialized data)
05
Fixed data-2
06, 07
Fixed data-1 (Initialized data)
08
09
0A
Fixed data-2
0B
0C to 0E
Fixed data-1 (Initialized data)
0F
10
Fixed data-2
11, 12
Fixed data-1 (Initialized data)
13
Fixed data-2
14 to 17
Fixed data-1 (Initialized data)
18
Fixed data-2
19 to 1F
Fixed data-1 (Initialized data)
20
21
Fixed data-2
22 to 3B
Fixed data-1 (Initialized data)
3C
3D
3E
Fixed data-2
3F
40 to 5C
Fixed data-1 (Initialized data)
5D
5E
Fixed data-2
5F
60, 61
Fixed data-1 (Initialized data)
62
Fixed data-2
63 to 6E
Fixed data-1 (Initialized data)
6F
70
Fixed data-2
71
Fixed data-1 (Initialized data)
72
73
Fixed data-2
74 to BA
Fixed data-1 (Initialized data)
BB
Fixed data-2
BCZ
Fixed data-1 (Initialized data)
BD
Fixed data-2
BE to FF
Fixed data-1 (Initialized data)
6-17
DCR-SR90E/SR100/SR100E_ADJ
F Page table
Address
Initial value
Remark
NTSC PAL
44
2D
2D
45
80
80
46
5A
5A
AWB adj.
47
40
40
48
11
11
49
C9
C9
4A
4C
4C
4B
52
52
4C
23
23
4D
92
92
4E
00
00
4F
00
00
50
00
00
Flange back adj.
51
00
00
52
69
69
53
19
19
54
19
19
55
26
26
56
00
00
57
06
06
58
00
00
MR adj./Flange back adj.
59
Fixed data-1 (Initialized data)
5A
80
80
5B
80
80
5C
80
80
5D
80
80
5E
40
40
5F
C0
C0
60
40
40
MR adj.
61
C0
C0
62
40
40
63
C0
C0
64
40
40
65
C0
C0
66 to 6C
Fixed data-1 (Initialized data)
6D
00
00
Flange back adj.
6E to 71
Fixed data-1 (Initialized data)
72
73
Fixed data-2
74, 75
Fixed data-1 (Initialized data)
76
C6
A4
77
00
00
78
86
70
79
00
00
Mechanical shutter adj.
7A
66
56
7B
00
00
7C
50
43
Address
Initial value
Remark
NTSC PAL
7D
00
00
7E
40
35
7F
00
00
80
50
50
81
5D
5D
82
58
58
83
4E
4B
84
3E
3A
Mechanical shutter adj.
85
20
20
86
80
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
80
8C
04
04
8D
80
80
8E
80
80
8F
80
80
Strobe light level adj.
90
80
80
91
20
20
92 to AF
Fixed data-1 (Initialized data)
B0
Fixed data-2
B1 to CF
Fixed data-1 (Initialized data)
D0
Fixed data-2
D1 to F7
Fixed data-1 (Initialized data)
F8
F9
Fixed data-2
FA
FB to FF
Fixed data-1 (Initialized data)
6-18
DCR-SR90E/SR100/SR100E_ADJ
5.
14 Page table
Note 1: If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 3F
Fixed data-1 (Initialized data)
40
41
Fixed data-2
42
Fixed data-1 (Initialized data)
43
44
Fixed data-2
45 to 97
Fixed data-1 (Initialized data)
98
00
00
99
00
00
9A
00
00
9B
00
00
9C
00
00
Mixed color compensation adj.
9D
00
00
9E
00
00
9F
00
00
A0
F5
F5
A1
EE
EE
A2
3A
3A
A3
2C
2C
Color reproduction adj.
A4
03
03
A5
FE
FE
A6
35
35
A7
38
38
A8
00
00
A9
00
00
AA
00
00
AB
00
00
AC
00
00
AD
00
00
AE
00
00
AF
00
00
Mixed color compensation adj.
B0
00
00
B1
00
00
B2
00
00
B3
00
00
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8 to D8
Fixed data-1 (Initialized data)
Address
Initial value
Remark
NTSC PAL
D9
DA
Fixed data-2
DB
DC to E7
Fixed data-1 (Initialized data)
E8
1A
1A
E9
00
00
EA
07
07
EB
00
00
EC
1A
1A
ED
00
00
EE
07
07
AWB standard data input
EF
00
00
F0
1A
1A
F1
00
00
F2
07
07
F3
00
00
F4
11
11
F5
00
00
F6
0A
0A
F7
00
00
F8
11
11
F9
00
00
FA
0A
0A
AWB adj.
FB
00
00
FC
11
11
FD
00
00
FE
0A
0A
FF
00
00
Page of 66