Movie / SECTION 6 ADJUSTMENTS
File
dcr-ip210-dcr-ip210e-dcr-ip220-dcr-ip220e-sm4.pdf
Date

Sony DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) Service Manual ▷ View online

6-34
DCR-IP210/IP210E/IP220/IP220E
18. Strobe White Balance Adjustment & Check
Adjust and check the white balance when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)(Note1)
Measurement Point
Video terminal of A/V jack
(75
 terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
3E, 3F
Specified Value
Fig. 6-1-15.
Note1:
Background paper (J-250-130-A). Perform this adjustment in the
dark room or use the flash adjustment box. (Refer to “1-1-3.
Precaution”.)
Note2:
Any light other than the strobe light should not light up the paper.
Note3:
This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”,  “Auto White Balance
& LV Standard Data Input”, “Auto White Balance Adjustment”,
“Strobe Light Level Adjustment”
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
FLASH ......................................................................... OPEN
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
05
04
Set the data. (Note6)
3
6
01
B9
Set the data, and press PAUSE
button.
4
Check the flashing.
5
6
02
Check that the data is “01”.
(Note7)
6
6
01
00
Set the data, and press PAUSE
button.
7
Wait for 1 sec.
8
6
01
E7
Set the data, and press PAUSE
button.
9
Check the flashing.
10
Wait for 3 sec.
11
Check that the center of the
white luminance point is within
the circle shown Fig. 6-1-15.
Note6:
Use the STOP button of the adjustment remote commander.
Note7:
The adjustment data will be automatically input to page: F, address:
3E, 3F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
7
05
00
Set the data.
3
0
01
00
Set the data.
19. AF Laser Output Adjustment
Set the AF laser output to an appropriate level.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)
(Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
66 to 6C
Specified Value
Data of address: 66 is “10” to “FF”.
Data of address: 67 is “00” to “58”.
Data of address: 68 is “0A” to “FF”.
Data of address: 6B is “6E” to “A4”.
Note1:
Background paper (J-250-130-A). Perform this adjustment in the
dark room or use the flash adjustment box. (Refer to “1-1-3.
Precaution”.)
Note2:
Any light other than the laser light should not light up the paper.
Note3:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”,  “MR Adjustment”,  “Flange Back
Adjustment”
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
AF
Set the data, and press PAUSE
button.
3
Check the laser light is output.
4
6
02
Check that the data is “01”. (Note5)
5
F
66
Check that the data is “10” to “FF”.
6
F
67
Check that the data is “00” to “58”.
7
F
68
Check that the data is “0A” to “FF”.
8
F
6B
Check that the data is “6E” to “A4”.
Note5:
The adjustment data will be automatically input to page: F, address:
66 to 6C.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
Fig. 6-1-15.
R-Y
2mm
B-Y
2mm
6-35
DCR-IP210/IP210E/IP220/IP220E
20. AF Laser Axis Check
Subject
Dark homogeneous subject
(1m from the front of the lens) (Note1)
Measurement Point
Video terminal of A/V jack
Measuring Instrument
Monitor TV
Specified Value
Two or more hologram lines are
perfectly within the inspection frame.
The hologram lines can be seen at
every outside of the inspection frame.
Note1:
Background paper (J-250-130-A) etc.. Perform this adjustment in
the dark place.
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ................................................................. MEMORY
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
Checking method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
E
EF
82
Set the data.
3
6
23
04
Set the data.
4
6
5B
B4
Set the data.
5
6
5C
B4
Set the data.
6
6
90
DB
Set the data.
7
6
91
02
Set the data.
8
6
92
C0
Set the data.
9
6
93
46
Set the data.
10
6
01
79
Set the data, and press PAUSE
button.
11
6
01
78
Set the data, and press PAUSE
button.
12
Check that two or more
hologram lines are perfectly
within the inspection frame.
13
Check that the hologram lines
can be seen at every outside of
the inspection frame on the
monitor TV screen (the top, the
bottom, the left and the right).
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
E
EF
00
Set the data.
2
6
23
00
Set the data.
3
6
5B
00
Set the data.
4
6
5C
00
Set the data.
5
6
90
00
Set the data.
6
6
91
00
Set the data.
7
6
92
00
Set the data.
8
6
93
00
Set the data.
9
6
01
00
Set the data, and press PAUSE
button.
10
0
01
00
Set the data.
Fig. 6-1-16.
Inspection frame
6-36
DCR-IP210/IP210E/IP220/IP220E
21. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03MA
Type B: ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2B00 to 4B00
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(VF-155 board SE3001)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value.
Yaw sensor check
(VF-155 board SE3002)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
Move the camcorder, and check
that the steady shot operations
have been performed normally
6-37
DCR-IP210/IP210E/IP220/IP220E
1-4.
COLOR ELECTRONIC VIEWFINDER
SYSTEM ADJUSTMENT
Note1:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note2:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note3:
When performing the viewfinder system adjustments with the LCD
panel open, perform the following data setting before the
adjustments. (This data setting will be canceled, when the
automatic adjustment is done.)
1) Select page: 3, address: 00, set data: 01 and press PAUSE
button.
2) Select page: 3, address: 02, and set data: 02.
Reset the data after completing adjustment.
1) Select page: 3, address: 00, set data: 00 and press PAUSE
button.
2) Select page: 3, address: 02, and set data: 00.
Switch setting:
LCD panel .................... Closed (Close the LCD panel so that
the LCD screen can’t be seen. Note3)
[Measuring points]
The measuring points for manual adjustment are Pin eg (EXT DA)
and Pin ws (VG) of IC2201 of DI-087 board.
Fig. 6-1-17.
24
25
36
37
48
1
13
12
IC2201
DI-087 board (SIDE B)
COVER
COVER