6-46
DCR-IP210/IP210E/IP220/IP220E
6. Center Level Adjustment (PD-166 Board)
Set the video signal center level of LCD panel to an appropriate
level.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 1 of CN803 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
C
Adjustment Address
8D
Specified Value
A = 7.00 ± 0.05Vdc
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
8D
Change the data and set the DC
voltage (A) to the specified value.
(The data should be “00” to “7F”.)
3
C
8D
Press PAUSE button.
4
0
01
00
Set the data.
7. V-COM Adjustment (PD-166 Board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
C
Adjustment Address
86
Specified Value
The brightness difference between the
section A and section B is minimum.
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
Bright adjustment, Black limit adjustment, Contrast adjustment,
Center level adjustment
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
86
Change the data so that the
brightness of the section A and
that of the section B is equal.
(Note3)
3
C
86
Subtract 2 from the data. (Note3)
4
C
86
Press PAUSE button.
5
0
01
00
Set the data.
Note3:
The data should be “80” to “BF”.
Fig. 6-1-25.
A
A
A
A
B
B
B
B
6-47
DCR-IP210/IP210E/IP220/IP220E
8. White Balance Adjustment (PD-166 Board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
8A, 8B
Specified Value
The LCD screen should not be colored.
Note1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC801
Note2:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
8A
7F
Set the data, and press PAUSE
button.
3
C
8B
61
Set the data, and press PAUSE
button.
4
C
8B
Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5
C
8A
Change the data so that the LCD
screen is not colored.
6
C
8A
Press PAUSE button.
7
C
8B
Change the data so that the LCD
screen is not colored.
8
C
8B
Press PAUSE button.
9
C
8B
If the LCD screen is colored,
repeat steps 5 to 9.
10
0
01
00
Set the data.
6-48
DCR-IP210/IP210E/IP220/IP220E
COVER
COVER
6-2. MECHANISM SECTION
ADJUSTMENT
On the mechanism section adjustment
For detail of mechanism section adjustments, checks, and
replacement of mechanism parts, refer to the separate volume
“MICRO MV MECHANICAL ADJUSTMENT MANUAL 1
 V Mechanism  ”.
Note:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
2-1.
Adjustment Remote Commander
Connect the adjustment remote commander to LANC jack.
2-2.
OPERATING WITHOUT CASSETTE
1)
Connect the adjustment remote commander.
2)
Turn on the HOLD switch of the adjustment remote
commander.
3)
Close the cassette compartment without loading a cassette and
complete loading.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: 9, address: 74, set data: 01, and press the PAUSE
button.
6)
Select page: 9, address: 81, set data: 01, and press the PAUSE
button.
7)
Select page: 9, address: C4, set data: 02, and press the PAUSE
button.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette. Never do opening or closing of the
cassette compartment under this condition.
Be sure to carry out “Procedure checking operations” after
checking the operations.
Set the following data to page: D, address: 10, if the forced
power supply ON mode is to be used together.
   Forced VTR power supply ON mode .............................. 02
   Forced CAMERA power supply ON mode ..................... 01
 [Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 9, address: 74, set data: 00, and press the PAUSE
button.
3)
Select page: 9, address: 81, set data: 00, and press the PAUSE
button.
4)
Select page: 9, address: C4, set data: 00, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
6)
Disconnect the power supply of the unit.
Fig. 6-2-1.
2-3.
TAPE PATH ADJUSTMENT
The lens block (CD-406 board) must be connected when performing
the adjustment.
1. Preparation for Adjustment
1)
Clean the tape running side (tape guide, capstan shaft, pinch
roller, etc.).
2)
Connect an oscilloscope to CN452 of VC-308 board.
Channel 1: CN452 Pin 3 (or CL457) (Note)
External trigger: CN452 Pin 7 (or CL458)
Note:
Connect a 75
 resistor (1-247-804-11) between Pins 3 of
CN452 and GND.
3)
Playback the alignment tape for tracking. (XH8-1)
4)
Connect the adjustment remote commander and turn the HOLD
switch to the ON position.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: 9, address: BC, set data: 0D, and press the PAUSE
button.
7)
Select page: 9, address: B1, set data: 62, and press the PAUSE
button.
8)
Select page: 0, address: 01, and set data: 00.
9)
Select page: 3, address: 0A, set data: 40, and press the PAUSE
button.
10) Check that the data of page: 3, address: 0B changes from “40”
to “00”.
11) Rotate the HOLD OFF knob of the oscilloscope so that the
flattest waveform is displayed.
12) Check that the oscilloscope RF waveform is normal at the
entrance and exit.
If not normal, adjust according to the separate volume
“MICRO MV MECHANICAL ADJUSTMENT MANUAL 1
  V Mechanism  ”.
CN452 of VC-308 board
Note1:
Or CL457
Note2:
Or CL458
Table. 6-2-1.
2. Processing after Completing Operations:
1)
Connect the adjustment remote commander and set the HOLD
switch to the ON position.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 9, address: BC, set data: 00, and press the PAUSE
button.
4)
Select page: 9, address: B1, set data: 22, and press the PAUSE
button.
5)
Select page: 0, address: 01, and set data: 00.
Pin No.
1
3 (Note1)
5
7 (Note2)
9
11
13
15
17
19
21
Signal Name
D 2.8V
RF MON OUT
QTM2
SWP
MD0
RH RST
SWP SO
MD2
XSYS RST
DRUM ON
REG GND
Pin No.
2
4
6
8
10
12
14
16
18
20
Signal Name
CPC ENV OUT
QTM1
RAW PB
MD2
DIS HISIO
PLL ON DIA
SCK3
XCS MC FLASH
XCS ST IMAGE IC
FRRV
5msec
CH1
Trigger
6-49
DCR-IP210/IP210E/IP220/IP220E
6-3. VIDEO SECTION ADJUSTMENT
NTSC model: DCR- IP210/IP220
PAL model: DCR- IP210E/IP220E
3-1.
PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1.
Equipment to Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• Tracking (XH8-1)
Parts code: 8-967-998-01
• SW V&A NTSC (XH8-2)
Parts code: 8-967-998-11
• SW V&A PAL (XH8-3)
Parts code: 8-967-998-21
12) Adjustment remote commander (J-6082-053-B)