DOWNLOAD Sony DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) Service Manual ↓ Size: 1.39 MB | Pages: 76 in PDF or view online for FREE

Model
DCR-IP210 DCR-IP210E DCR-IP220 DCR-IP220E (serv.man4)
Pages
76
Size
1.39 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-ip210-dcr-ip210e-dcr-ip220-dcr-ip220e-sm4.pdf
Date

Sony DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) Service Manual ▷ View online

6-22
DCR-IP210/IP210E/IP220/IP220E
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments (except for
“67.5MHz/54MHz Origin Oscillation Adjustment”), check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are
satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note:
NTSC model: DCR- IP210/IP220
PAL model: DCR- IP210E/IP220E
1. 67.5MHz/54MHz Origin Oscillation Adjustment
(CD-406 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin rf of IC1100 (FB1106)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified Value
f=33750000 ± 170Hz (NTSC)
f=27000000 ± 135Hz (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Set the data.
Fig. 6-1-8.
2. Zoom Key Center Adjustment
Set the A/D value center of the microprocessor to the center voltage
of the zoom key.
If deviated, the zoom lens operates of itself, even if the zoom key is
the center position.
Subject
Not required
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
11
Note1:
Perform this adjustment under the condition that the zoom switch
(RV4001 of the control switch block (SS-2980)) is surely
connected.
Note2:
Don’t touch the zoom switch during adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note4)
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
Note4:
The adjustment data will be automatically input to page: F, address:
11.
IC1100
CD-406 board
FB1106
COVER
COVER
6-23
DCR-IP210/IP210E/IP220/IP220E
3. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
13 to 18
Specified Value 1
D6 to DA
Specified Value 2
26 to 2A
Specified Value 3
D6 to DA
Specified Value 4
26 to 2A
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
6D
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note3)
4
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
13 to 18.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
6
01
01
Set the data, and press PAUSE button.
3
6
01
03
Set the data, and press PAUSE button.
4
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
5
6
01
01
Set the data, and press PAUSE button.
6
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
7
6
01
6B
Set the data, and press PAUSE button.
8
6
01
69
Set the data, and press PAUSE button.
9
1
Check that the ND display data
(Note1) satisfies the specified
value 3.
10
6
01
6B
Set the data, and press PAUSE button.
11
1
Check that the ND display data
(Note1) satisfies the specified
value 4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
3
0
01
00
Set the data.
4. CCD Output 2ch Matching Adjustment (1)
Correct the dispersion of the black level between the left-right
channels of the CCD imager.
Subject
Arbitrary
Adjustment Page
F
Adjustment Address
24 to 27
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”
Note2:
If this adjustment has been performed, the following adjustments
need to be performed again.
“CCD Output 2ch Matching Adjustment (2)”,  “Flange Back
Adjustment”, “Color Reproduction Adjustment”
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
F3
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
24 to 27.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
Perform “CCD Output 2ch
Matching Adjustment (2)”.
6-24
DCR-IP210/IP210E/IP220/IP220E
5. CCD Output 2ch Matching Adjustment (2)
Correct the dispersion between the left-right channels of the CCD
imager.
Subject
Clear chart (All white) (Note1)
Adjustment Page
F
Adjustment Address
29 to 2D
Note1:
Shoot the clear chart with the zoom TELE end.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
CCD Output 2ch Matching adjustment (1)
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
2C
01
Set the data.
3
6
40
01
Set the data.
4
6
01
F5
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01” in about 50 seconds after
pressing PAUSE button.
Note4:
The adjustment data will be automatically input to page: F, address:
29 to 2D
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
2C
00
Set the data.
3
6
40
00
Set the data.
4
0
01
00
Set the data.
6. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 70
Specified Value3
90 to FD
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5:
The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again
6-25
DCR-IP210/IP210E/IP220/IP220E
7. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
11, 48 to 58
Specified Value
Data of page: F, address: 57 is “00” to “09”.
Note1:
Dark Siemens star chart.
Note2:
Perform this adjustment under the condition that the zoom switch
(RV4001 of the control switch block (SS-2980)) is surely
connected.
Note3:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MR Adjustment”
Note4:
Make the lens horizontal and perform this adjustment.
Note5:
The data of page: 0, address: 10 must be “00”.
Note6:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER ............................................. OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm. (Remove
the lens hood.)
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage: The specified voltage varies according to the minipattern
box, so adjust the power supply output voltage to the
specified voltage written on the sheet which is supplied
with the minipattern box.
Fig. 6-1-9.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button. (Note7)
3
6
01
27
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01”. (Note8)
5
F
57
Check the data is “00” to “09”.
Note7:
Don’t touch the zoom switch, If you touch the zoom switch, the
zoom center adjustment data will be rewritten in the value that
isn’t correct.
Note8:
The adjustment data will be automatically input to page: F, address
11, 48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Flange Back Check”.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Page of 76
Display