DOWNLOAD Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ↓ Size: 1.07 MB | Pages: 79 in PDF or view online for FREE

Model
DCR-HC94E DCR-HC96 DCR-HC96E (serv.man4)
Pages
79
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc94e-dcr-hc96-dcr-hc96e-sm4.pdf
Date

Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ▷ View online

6-31
DCR-HC94E/HC96/HC96E_ADJ
11. Picture Frame Setting (Center frame)
Subject
Clear chart (Center frame)
(1 m (PTB-450) or 40 cm (PTB-
1450)  from the front of lens)
Measurement Point
Video terminal of A/V jack (or A/V
OUT jack) (75 
Ω terminated)
Measuring Instrument
Monitor TV
Specified Value
A clear chart must be shot in larger
size than nine grids in the center of
frame shown on the screen.
(Fig. 6-1-14)
Note: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) ZOOM .................................................................... WIDE end
5) DIGITAL ZOOM (Menu setting) .................................... OFF
6) STEADY SHOT (Menu setting) ..................................... OFF
7) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Shoot a clear chart in the
center of screen with the
zoom at WIDE end.
2
0
01
01
3
E
EF
91
Press PAUSE (Write) button.
4
Check that a clear chart is
shot in larger size than nine
grids in the center of frame
shown on the screen.
5
E
EF
00
Press PAUSE  (Write) button.
6
0
01
00
7
In the following adjustment,
if the “Center frame” is used,
adjust the clear chart to this
position.
Fig.6-1-15
A clear chart must be shot in larger size than central nine grids. 
12. F No. & ND Light Quality Standard Data Input
RadarW
RadarW
RadarW
Correct the lens iris and dispersion of the ND filter light quantity.
Adjustment Page
F
Adjustment Address
1C to 29
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: F, address: 1C to 29.
Note 2: Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address Data
1C
F9
1D
0B
1E
0D
1F
EC
20
E8
21
1A
22
02
23
07
24
D0
25
C8
26
E0
27
28
28
F1
29
F3
3) Select page: 0, address: 01, and set data: 00.
6-32
DCR-HC94E/HC96/HC96E_ADJ
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
79
Press PAUSE (Write) button
Processing after Completing Adjustment:
Reset the data setting after the adjustment finished.
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
Check on the monitor TV (Underscanned mode)
Fig.6-1-16
13. Picture Frame Setting (AWB Adjustment frame)
Subject
Clear chart (AWB Adjustment frame)
(1 m (PTB-450) or 40 cm (PTB-1450)
from the front of lens)
Measurement Point
Video terminal of A/V jack (or A/V
OUT jack) (75 
Ω terminated)
Measuring Instrument
Monitor TV
Specified Value
Only the clear chart must be shot
(entire screen is white).
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS ................................................................... MANUAL
Setting method:
Order Page Address Data
Procedure
1
Perform “9. Picture Frame
Setting (Color reproduction
adjustment frame)”.
2
By zooming in the color
reproduction adjustment
picture frame, set up the
picture frame in which the
color bar is shot on full
screen. (Refer to Fig. 6-1-16)
3
Remove the Color bar chart
from the pattern box.
4
Check that whole of the
screen is white.
5
0
03
18
6
1
Read XH data and XL data.
(Note 2)
7
0
03
22
8
1
Read YH data and YL data.
(Note 2)
9
0
03
00
10
In the following adjustment, if
the “AWB Adjustment frame”
is used, adjust the clear chart
to this position.
Color bar chart picture frame
Monitor TV picture frame
6-33
DCR-HC94E/HC96/HC96E_ADJ
15. LV Standard Data Input 
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Subject
Clear chart
(AWB Adjustment Frame)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
2A, 2B
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
6
01
0D
Press PAUSE (Write) button.
(Note 4)
4
6
02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
F, address: 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
00
14. Auto White Balance Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart
(AWB Adjustment Frame)
Adjustment Page
F
14 (Note 2)
Adjustment Address
2E to 31
E8 to F3
Note 1: Perform “F No.& ND Light Quality Standard Date In-
put” before this adjustment.
Note 2: If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
Wait for 2 seconds.
4
6
01
43
Press PAUSE (Write) button.
5
6
01
41
Press PAUSE (Write) button.
(Note 4)
6
6
02
Check the data changes to
“01”.
Note 4: The adjustment data will be automatically input to page:
F, address: 2E to 31 and page: 14, address: E8 to F3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
6-34
DCR-HC94E/HC96/HC96E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
Place the C14 filter on the
lens.
3
0
01
01
4
F
44
2C
Press PAUSE (Write) button.
5
F
45
Set the following data, and
Press PAUSE (Write) button.
F8: NTSC model
B8: PAL model
6
F
46
5A
Press PAUSE (Write) button.
7
F
47
20
Press PAUSE (Write) button.
8
6
01
47
Press PAUSE (Write) button.
9
6
01
45
Press PAUSE (Write) button.
(Note 5)
10
6
02
Check the data changes to
“01”.
Note 5: The adjustment data will be automatically input to page:
F, address: 32 to 35, 44 to 47 and page: 14, address: F4 to
FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
3
Remove the C14 filter on the
lens.
16. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(AWB Adjustment Frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14 (Note)
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2: If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4: NTSC model: DCR-HC96
PAL model: DCR-HC94E/HC96E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Page of 79
Display