Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ▷ View online

6-15
DCR-HC94E/HC96/HC96E_ADJ
6.
1C Page table
Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 77
Fixed data-1 (Initialized data)
78
Fixed data-2
79 to B2
Fixed data-1 (Initialized data)
B3
00
00
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
BE
00
00
SD error rate check (LP)
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to D4
Fixed data-1 (Initialized data)
D5
Fixed data-2
D6 to EB
Fixed data-1 (Initialized data)
EC
Fixed data-2
ED to EF
Fixed data-1 (Initialized data)
F0
Fixed data-2
F1 to F3
Fixed data-1 (Initialized data)
F4
Fixed data-2
F5
Fixed data-1 (Initialized data)
F6
Fixed data-2
F7 to FF
Fixed data-1 (Initialized data)
5.
18 Page table
Note 1: If reading/writing data on pages 18, set data: 01 to page:
0, address: 10, and then select pages: 8. By this data set-
ting, the pages 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00
Fixed data-1 (Initialized data)
01
Fixed data-2
02 to D7
Fixed data-1 (Initialized data)
D8
Fixed data-2
D9 to DC
Fixed data-1 (Initialized data)
DD
Fixed data-2
DE
Fixed data-1 (Initialized data)
DF
E0
Fixed data-2
E1 to E3
Fixed data-1 (Initialized data)
E4
Fixed data-2
E5 to F1
Fixed data-1 (Initialized data)
F2
Fixed data-2
F3 to F6
Fixed data-1 (Initialized data)
F7
Fixed data-2
F8 to FF
Fixed data-1 (Initialized data)
6-16
DCR-HC94E/HC96/HC96E_ADJ
1-2-3.
Initialization of E, F, 14, 19, 1E, 1F Page Data
1.
Initializing of E, F, 14, 19, 1E, 1F Page Data
Note 1: If “Initialization of Pages E, F, 14, 19, 1E, 1F” is ex-
ecuted, all data on pages E, F, 14, 19, 1E, 1F are initial-
ized. (Only an individual page cannot be initialized)
Note 2: If the E, F, 14, 19, 1E, 1F page data has been initialized,
the following adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustment (if all areas were initial-
ized)
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
14
Adjustment Address
00 to FF
Adjustment Page
19
Adjustment Address
00 to FF
Adjustment Page
1E
Adjustment Address
00 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE button.
3
6
01
2D: NTSC model
2F: PAL model
4
6
03
03
Press PAUSE (Write) button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE (Write) button.
7
Perform “Modification of E,
F, 14, 19, 1E, 1F Page Data”
Note 3: NTSC model: DCR-HC96
PAL model: DCR-HC94E/HC96E
2.
Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 14, 19, 1E, 1F, set data: 01 to
page: 0, address: 10, and then select pages 4, 9, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification E, F, 14, 19, 1E,
1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
6-17
DCR-HC94E/HC96/HC96E_ADJ
4.
F Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
Fixed data-1 (Initialized data)
Flange back and zoom lever center
11
80
80
adj.
12
Fixed data-1 (Initialized data)
13
28
28
14
70
70
15
40
40
16
80
80
17
19
19
Hall adj.
18
28
28
19
D8
D8
1A
28
28
1B
D8
D8
1C
00
00
1D
00
00
1E
00
00
1F
00
00
20
00
00
21
00
00
22
00
00
F No. & ND light quality standard
23
00
00
data input
24
E0
E0
25
D0
D0
26
C5
C5
27
63
63
28
00
00
29
00
00
2A
35
35
2B
00
00
LV standard data input
2C
68
78
MAX GAIN adj.
2D
Fixed data-1 (Initialized data)
2E
1A
1A
2F
00
00
Auto white balance standard
30
07
07
data input
31
00
00
32
11
11
33
00
00
34
0A
0A
Auto white balance adj.
35
00
00
36
Fixed data-1 (Initialized data)
37
41
41
Color reproduction adj.
38
Fixed data-1 (Initialized data)
3.
E Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 3B
Fixed data-1 (Initialized data)
3C
3D
3E
Fixed data-2
3F
40 to 5B
Fixed data-1 (Initialized data)
5C
5D
5E
5F
60
Fixed data-2
61
62
63
64 to E0
Fixed data-1 (Initialized data)
E1
E2
E3
Fixed data-2
E4
E5 to FF
Fixed data-1 (Initialized data)
6-18
DCR-HC94E/HC96/HC96E_ADJ
F Page table
Address
Initial value
Remark
NTSC PAL
39
2D
2D
Color reproduction adj.
3A to 3D
Fixed data-1 (Initialized data)
3E
2D
2D
3F
64
64
Strobe white balance adj.
40
02
02
41
DE
DE
Color reproduction adj.
42, 43
Fixed data-1 (Initialized data)
44
2C
2C
45
F8
B8
46
5A
5A
Auto white balance adj.
47
20
20
48
11
11
49
C9
C9
4A
4C
4C
4B
52
52
4C
23
23
4D
92
92
4E
00
00
4F
00
00
Flange back and zoom lever center
50
00
00
adj.
51
00
00
52
69
69
53
19
19
54
19
19
55
26
26
56
00
00
57
06
06
MR adj./Flange back and zoom
58
00
00
lever center adj.
59
Fixed data-1 (Initialized data)
5A
80
80
5B
80
80
5C
80
80
5D
80
80
5E
40
40
5F
C0
C0
60
40
40
MR adj.
61
C0
C0
62
40
40
63
C0
C0
64
40
40
65
C0
C0
66 to 6C
Fixed data-1 (Initialized data)
Flange back and zoom lever center
6D
00
00
adj.
6E to 71
Fixed data-1 (Initialized data)
Address
Initial value
Remark
NTSC PAL
72
73
Fixed data-2 (Note 3)
74, 75
Fixed data-1 (Initialized data)
76
C6
A4
77
00
00
78
86
70
79
00
00
7A
66
56
7B
00
00
7C
50
43
7D
00
00
7E
40
35
7F
00
00
80
50
50
81
5D
5D
Mechanical shutter adj.
82
58
58
83
4E
4B
84
3E
3A
85
20
20
86
80
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
80
8C
04
04
8D
80
80
8E
80
80
8F
80
80
Strobe light level adj.
90
80
80
91
20
20
92 to AF
Fixed data-1 (Initialized data)
B0
Fixed data-2
B1 to CF
Fixed data-1 (Initialized data)
D0
Fixed data-2
D1 to F7
Fixed data-1 (Initialized data)
F8
F9
Fixed data-2
FA
Fixed data-1 (Initialized data)
FB
Fixed data-2
FC to FF
Fixed data-1 (Initialized data)
Ver. 1.3  2007.09
Note 3: The data must be changed according to the suffix of  the
SI-054 Board, and accordingly refer to the Service
Manual LEVEL 2, Supplement-2 (9-876-932-84).
Page of 79
Display