DOWNLOAD Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ↓ Size: 1.07 MB | Pages: 79 in PDF or view online for FREE

Model
DCR-HC94E DCR-HC96 DCR-HC96E (serv.man4)
Pages
79
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc94e-dcr-hc96-dcr-hc96e-sm4.pdf
Date

Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ▷ View online

6-23
DCR-HC94E/HC96/HC96E_ADJ
3.
MR Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified value
Data of page: 6, address: 0C is “00”.
Note 1: Perform the adjustment with the lens in horizontal state.
Note 2: Perform “Flange Back Adjustment” after this adjustment.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Note 4: Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting
1) POWER CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
BD
Press PAUSE (Write) button.
(Note 5)
3
6
02
Check the data changes to
“01”.
4
6
0C
Check the data is “00”.
Note 5: The adjustment data will be automatically input to page:
F, address: 58, 5A to 65.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
0
01
00
6-24
DCR-HC94E/HC96/HC96E_ADJ
5.
CCD Output 2ch Matching Adjustmenr (2)
RadarW
RadarW
RadarW
Correct the dispersion of between the left-right channels of CCD
imager.
Subject
Clear chart (All white) (Note 1)
Adjustment Page
19 (Note 3)
Adjustment Address
00 to 11
Note 1: Shoot the clear chart with the zoom TELE end.
Note 2: Peform “CCD Output 2ch Matching Adjustment (1)”
before this adjustment.
Note 3: If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) ZOOM ..................................................................... TELE end
4) STEADY SHOT (Menu setting) ..................................... OFF
5) Focus (Menu setting) ............................................. MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
F5
Press PAUSE (Write) button.
(Note 5)
3
6
02
Check the data changes to
“01” .
Note 5: The adjustment data will be automatically input to page:
19, address: 00 to 11.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
4.
CCD Output 2ch Matching Adjustmenr (1)
RadarW
RadarW
RadarW
Correct the dispersion of black level between the left-right chan-
nels of CCD imager.
Subject
Not required
Adjustment Page
19 (Note 3)
Adjustment Address
14 to 1F
Note 1: Perform “HALL Adjustment” before this adjustment.
Note 2: Perform “CCD Output 2ch Matching Adjustment (2)”,
“Flange Back Adjustment” and “Color Reproduction Ad-
justment” after this adjustment.
Note 3: If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 4: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
F3
Press PAUSE (Write) button.
(Note 5)
3
6
02
Check the data changes to
“01” .
Note 5: The adjustment data will be automatically input to page:
19, address: 14 to 1F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
6-25
DCR-HC94E/HC96/HC96E_ADJ
Order Page Address Data
Procedure
6
0
01
00
7
Perform “Flange Back
Check”.
Preparation (Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note 9: The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-9
Preparation (Using the flange back adjustment jig)
(Luminance: about 300 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-10
6.
Flange Back and Zoom Lever Center Adjustment
RadarW
RadarW
RadarW
 (Using the minipattern box or flange
back adjustment jig)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
minipattern box (Note 1) or flange
back adjustment jig
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
11, 48 to 58, 6D
Specified value
Data of pege: 6, address: 0C is “00”
Note 1: Dark Siemens star chart.
Note 2: Perform “HALL Adjustment”,“MR Adjustment” and
“CCD Output 2ch Matching Adjustment”before this ad-
justment.
Note 3: Perform the adjustment with the lens in horizontal state.
Note 4: Check that the data of page: 0, address: 10 is “00”.
Note 5: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) COLOR SLOW S (Menu setting) ................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
E
FD
Set the bit value of bit4 is
“1”, and press PAUSE
(Write) button. (Note 7)
3
6
01
13
Press PAUSE (Write) button.
4
6
01
27
Press PAUSE (Write) button.
(Note 8)
5
6
02
Check the data changes to “01”.
6
6
0C
Check the data is “00”.
Note 7: For the bit values, refer to “6-4. SERVICE MODE”, “4-
4. 3. Bit value discrimination”.
Note 8: The adjustment data will be automatically input to page:
F, address: 11, 48 to 58 and 6D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
E
FD
Set the bit value of bit4 is
“0”, and press PAUSE
(Write) button. (Note 7)
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
± 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
6-26
DCR-HC94E/HC96/HC96E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
E
FD
Set the bit value of bit4 is
“1”, and press PAUSE
(Write) button. (Note 6)
3
6
01
13
Press PAUSE (Write) button.
4
6
01
15
Press PAUSE (Write) button.
(Note 7)
5
6
02
Check the data changes to
“01”.
6
6
0C
Check the data is “00”.
Note 6: For the bit values, refer to “6-4. SERVICE MODE”, “4-
4.3. Bit value discrimination”.
Note 7: The adjustment data will be automatically input to page:
F, address: 11, 48 to 58 and 6D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
E
FD
Set the bit value of bit4 is
“0”, and press PAUSE
(Write) button. (Note 6)
6
0
01
00
7
Perform “Flange Back
Adjustment (2)”.
7.
Flange Back and Zoom Lever Center Adjustment
(Using the flange back adjustment chart and
subject more than 500 m away)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
7-1. Flange Back Adjustment (1) 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Flange back adjustment chart
(2.0 m from the front of lens)
(Luminance: 300 to 400 lux)
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
11, 48 to 58, 6D
Specified value
Data of page: 6, address: 0C is“00”
Note 1: Perform “HALL Adjustment”,“MR Adjustment” and
“CCD Output 2ch Matching Adjustment”before this ad-
justment.
Note 2: Perform the adjustment with the lens in horizontal state.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Note 4: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: Don’t touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) COLOR SLOW S (Menu setting) ................................... OFF
Preparations before adjustments:
1) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
Page of 79
Display