DOWNLOAD Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ↓ Size: 1.07 MB | Pages: 79 in PDF or view online for FREE

Model
DCR-HC94E DCR-HC96 DCR-HC96E (serv.man4)
Pages
79
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc94e-dcr-hc96-dcr-hc96e-sm4.pdf
Date

Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) Service Manual ▷ View online

6-39
DCR-HC94E/HC96/HC96E_ADJ
21. Mechanical Shutter Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the close time and loss time every F number of the me-
chanical shutter and the high-speed shutter correction value to
correct the luminous exposure.
Adjustment Page
F
Adjustment Address
76 to 8B
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: NTSC model: DCR-HC96
PAL model: DCR-HC94E/HC96E
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: F, address: 76 to 8B.
Note: Press the PAUSE (Write) button of the adjustment remote
commander each time to set data.
Address
Data
NTSC
PAL
76
B7
97
77
1E
15
78
83
6B
79
60
5C
7A
67
54
7B
39
4F
7C
52
43
7D
91
34
7E
42
35
7F
5B
D1
80
58
56
81
62
61
82
60
5E
83
58
56
84
4D
4A
85
20
1F
86
7E
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
7F
80
3) Select page: 0, address: 01, and set data: 00.
20. MAX GAIN Adjustment 
RadarW
RadarW
RadarW
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects
in low illuminance will not be produced (dark).
Subject
Clear chart (Center frame)
Adjustment Page
F
Adjustment Address
2C
Note 1: Perform “Flange Back and Zoom Lever Center Adjust-
ment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 4: NTSC model: DCR-HC96
PAL model: DCR-HC94E/HC96E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT ................................................................... OFF
3) WIDE SELECT .................................................................. 4:3
4) ZOOM .................................................................... WIDE end
5) DIGITAL ZOOM (Menu setting) .................................... OFF
6) STEADY SHOT (Menu setting) ..................................... OFF
7) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Perform “8. Picture Frame
Setting (Center Frame)”
2
0
01
01
3
6
D0
Set the following data.
29: NTSC model
14: PAL model
4
6
D1
00
5
6
01
6F
Press PAUSE (Write) button.
(Note 5)
6
6
02
Check the data changes to
“01”.
Note 5: The adjustment data will be automatically input to page:
F, address: 2C.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
D0
00
2
6
D1
00
3
6
01
00
Press PAUSE (Write) button.
4
0
01
00
6-40
DCR-HC94E/HC96/HC96E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
01
7E
3
7
04
01
4
7
00
01
Press PAUSE (Write) button.
5
6
01
67
Press PAUSE (Write) button.
(Note 7)
6
Check the flashing.
7
6
02
Check the data changes to
“00”.
8
6
0C
Check the data is “00” or “01”.
9
E
01
06
Press PAUSE (Write) button.
10
6
B6
0C
11
1
Check that the display data
(Note 6) satisfies the
specified value 2.
Note 7: The adjustment data will be automatically input to page:
F, address: 8C to 91.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
B6
00
3
E
01
00
Press PAUSE (Write) button.
4
7
01
7E
5
7
04
00
6
7
00
01
Press PAUSE (Write) button.
7
0
01
00
22. Strobe Light Level Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjustment the strobe light level.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Display data of page: 1 (Note 6)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
8C to 91
Specified Value 1
Data of page: 6, address: 0C is “00”
or “01”
Specified value 2
1000 or less
Note 1: Perform “Hall Adjustment”, “Flange Back Adjustment”
and “F No. & ND Light Quantity Standard Date Input”
before this adjustment.
Note 2: Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refor to “4. Preparing the Flash adjustment box”. (See
page: 6-7)
Note 4: Check that the data of page: 0, address: 10 is “00”.
Note 5: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 6: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) FLASH ................................................................. Forced flash
(Press the FLASH button and set to the forced flash mode.)
3) NIGHTSHOT ................................................................... OFF
How to reset the flash error flag
When the flash error code (E:91: ** ) is displayed. After repair,
clear the error flag in the following method.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data is “01”.
6-41
DCR-HC94E/HC96/HC96E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
7
01
7E
3
7
04
01
4
7
00
01
Press PAUSE (Write) button.
5
6
01
B9
Press PAUSE (Write) button.
(Note 8)
6
Check the flashing.
7
6
02
Check the data changes to
“01”.
8
6
01
00
Press PAUSE (Write) button.
9
Waie for 3 seconds.
10
6
01
E7
Press PAUSE (Write) button.
11
Check the flashing.
12
0
03
33
13
1
Check that bit15 of the
display data (Note 7) is “01”.
(Note 9)
Note 8: The adjustment data will be automatically input to page:
F, address: 3E, 3F.
Note 9: When bit15 of the display data is “1”, the display data is
“8000” to “FFFF”.
If the specified value is not satisfied. Contents of the er-
ror are displayed at the lower digit (bit0 to bit3) of the
display data. (For the bit values, refer to “6-4. SERVICE
MODE”,“4-4. 3. Bit value disrimination”.)
bit0 = 1: The white balance is deviated in the blue di-
rection
bit1 = 1: The white balance is deviated in the yellow
direction
bit2 = 1: The white balance is deviated in the red di-
rection
bit3 = 1: The white balance is deviated in the cyan di-
rection
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
7
01
7E
3
7
04
00
4
7
00
01
Press PAUSE (Write) button.
5
0
03
00
6
0
01
00
23. Strobe White Balance Adjustment & Check
RadarW
RadarW
RadarW
Adjust and check the white balance when the strobe light flashed.
Subject
Flash adjustment box (Note 3)
(50 cm from the front of the lens)
Measurement Point
Displayed data of page: 1 (Note 7)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
3E, 3F
Specified Value
bit15 is “1”
Note 1: Perform “Hall Adjustment”, “Flange Back Adjustment”,
“AWB Adjustment” and “Strobe Light Level Adjustment”
before this adjustment.
Note 2: Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3: Refer to “4. Preparing the Flash adjustment box”. (See
page 6-7)
Note 4: “Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Note 5: Check that the data of page: 0, address: 10 is “00”.
Note 6: Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 7: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) FLASH ................................................................. Forced flash
(Press the FLASH button and set to the forced flash mode.)
3) NIGHTSHOT ................................................................... OFF
How to reset the flash error flag
When the flash error code (E:91: ** ) is displayed. After repair,
clear the error flag in the following method.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data is “01”
6-42
DCR-HC94E/HC96/HC96E_ADJ
24. Steady Shot Check 
RadarW
RadarW
RadarW
Precautions on the Parts Replacement
There are two types of repair parts.
Type A ENC03RA
Type B ENC03RB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified value
PITCH data: 2680 to 5080
YAW data: 2680 to 5080
Note 1: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Note 2: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) ZOOM ..................................................................... TELE end
2) STEADY SHOT (Menu setting) ....................................... ON
Checking method:
Order Page Address Data
Procedure
  PITCH sensor output check (SE401 of SI-054 board)
1
0
03
11
2
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the PITCH
data specified value.
  YAW sensor output check (SE402 of SI-054 board)
3
0
03
12
4
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the YAW
data specified value.
5
0
03
00
  Steady shot operation check
6
Shake the set vertically and
horizontally to check that the
steady shot function operates
normally.
Page of 79
Display

Click on the first or last page to see other DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man4) service manuals if exist.