DOWNLOAD Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual ↓ Size: 788.14 KB | Pages: 77 in PDF or view online for FREE

Model
DCR-HC47E DCR-HC48 DCR-HC48E (serv.man4)
Pages
77
Size
788.14 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc47e-dcr-hc48-dcr-hc48e-sm4.pdf
Date

Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual ▷ View online

6-15
DCR-HC47E/HC48/HC48E_ADJ
5.
18 Page table
Note 1: If reading/writing data on pages 18, set data: 01 to page:
0, address: 10, and then select pages: 8. By this data set-
ting, the pages 18 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to D7
Fixed data-1 (Initialized data)
D8
Fixed data-2
D9 to DC
Fixed data-1 (Initialized data)
DD
Fixed data-2
DE
Fixed data-1 (Initialized data)
DF
E0
Fixed data-2
E1 to E3
Fixed data-1 (Initialized data)
E4
Fixed data-2
E5 to F1
Fixed data-1 (Initialized data)
F2
Fixed data-2
F3 to FF
Fixed data-1 (Initialized data)
6.
1C Page table
Note 1: If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to“00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to B2
Fixed data-1 (Initialized data)
B3
00
00
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
Error rate check
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to EF
Fixed data-1 (Initialized data)
F0
Fixed data-2
F1 to FF
Fixed data-1 (Initialized data)
6-16
DCR-HC47E/HC48/HC48E_ADJ
1-2-3.
Initialization of 63 to 6F Page Data
1.
Initializing of 63 to 6F Page Data
Note 1: If “Initialization of Pages 63 to 6F” is executed, all data
on pages 63 to 6F are initialized. (Only an individual
page cannot be initialized)
Note 2: If the 63 to 6F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of 63 to 6F page data
2) Camera system adjustment
Adjustment Page
63
Adjustment Address
00 to 4F
Adjustment Page
64
Adjustment Address
00 to 8F
Adjustment Page
65
Adjustment Address
00 to 2F
Adjustment Page
66
Adjustment Address
00 to FF
Adjustment Page
67
Adjustment Address
00 to 6F
Adjustment Page
68
Adjustment Address
00 to AF
Adjustment Page
69
Adjustment Address
00 to 4F
Adjustment Page
6A
Adjustment Address
00 to AF
Adjustment Page
6B
Adjustment Address
00 to 5F
Adjustment Page
6C
Adjustment Address
00 to 4F
Adjustment Page
6D
Adjustment Address
00 to FF
Adjustment Page
6E
Adjustment Address
00 to 1F
Adjustment Page
6F
Adjustment Address
10 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
6
01
Set the following data, and
press PAUSE (Write) button.
2D: NTSC model
2F: PAL model
4
6
03
01
Press PAUSE (Write) button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE (Write) button.
7
Perform “Modification of 63
to 6F Page Data”
Note 3: NTSC model: DCR-HC48
PAL model: DCR-HC47E/HC48E
2.
Modification of 63 to 6F Page Data
If the 63 to 6F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 63 to 6F, set data: 06 to page:
0, address: 10, and then select pages 3 to F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 63 to 6F page
data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
3.
63 Page table
Note 1: If reading/writing data on pages 63, set data: 06 to page:
0, address: 10, and then select pages: 3. By this data
setting, the pages 63 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 09
Fixed data-1 (Initialized data)
0A
0B
Fixed data-2
0C to 4F
Fixed data-1 (Initialized data)
6-17
DCR-HC47E/HC48/HC48E_ADJ
4.
64 Page table
Note 1: If reading/writing data on pages 64, set data: 06 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 64 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 7C
Fixed data-1 (Initialized data)
7D
Fixed data-2
7E
Fixed data-1 (Initialized data)
7F
80
81
Fixed data-2
82
83 to 8F
Fixed data-1 (Initialized data)
5.
65 Page table
Note 1: If reading/writing data on pages 65, set data: 06 to page:
0, address: 10, and then select pages: 5. By this data set-
ting, the pages 65 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 2F
Fixed data-1 (Initialized data)
6.
66 Page table
Note 1: If reading/writing data on pages 66, set data: 06 to page:
0, address: 10, and then select pages: 6. By this data set-
ting, the pages 66 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 69
Fixed data-1 (Initialized data)
6A
6B
Fixed data-2
6C to C1
Fixed data-1 (Initialized data)
C2
C3
Fixed data-2
C4 to FF
Fixed data-1 (Initialized data)
7.
67 Page table
Note 1: If reading/writing data on pages 67, set data: 06 to page:
0, address: 10, and then select pages: 7. By this data set-
ting, the pages 67 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 13
Fixed data-1 (Initialized data)
14
15
Fixed data-2
16 to 6F
Fixed data-1 (Initialized data)
8.
68 Page table
Note 1: If reading/writing data on pages 68, set data: 06 to page:
0, address: 10, and then select pages: 8. By this data set-
ting, the pages 68 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 07
Fixed data-1 (Initialized data)
08
Fixed data-2
09 to 74
Fixed data-1 (Initialized data)
75
Fixed data-2
76
Fixed data-1 (Initialized data)
77
Fixed data-2
78 to 91
Fixed data-1 (Initialized data)
92
93
Fixed data-2
94
Fixed data-1 (Initialized data)
95
Fixed data-2
96 to AF
Fixed data-1 (Initialized data)
6-18
DCR-HC47E/HC48/HC48E_ADJ
9.
69 Page table
Note 1: If reading/writing data on pages 69, set data: 06 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 69 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 09
Fixed data-1 (Initialized data)
0A
0B
Fixed data-2
0C to 45
Fixed data-1 (Initialized data)
46
Fixed data-2
47, 48
Fixed data-1 (Initialized data)
49
Fixed data-2
4A to 4F
Fixed data-1 (Initialized data)
10. 6A Page table
Note 1: 
If reading/writing data on pages 6A, set data: 06 to page:
0, address: 10, and then select pages: A. By this data set-
ting, the pages 6A can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to AF
Fixed data-1 (Initialized data)
11. 6B Page table
Note 1: 
If reading/writing data on pages 6B, set data: 06 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 6B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 5F
Fixed data-1 (Initialized data)
12. 6C Page table
Note 1: 
If reading/writing data on pages 6C, set data: 06 to page:
0, address: 10, and then select pages: C. By this data set-
ting, the pages 6C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 38
Fixed data-1 (Initialized data)
39
Fixed data-2
3A to 4F
Fixed data-1 (Initialized data)
13. 6D Page table
Note 1: 
If reading/writing data on pages 6D, set data: 06 to page:
0, address: 10, and then select pages: D. By this data
setting, the pages 6D can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 58
Fixed data-1 (Initialized data)
59
Fixed data-2
5A to 5E
Fixed data-1 (Initialized data)
5F
Fixed data-2
60 to 63
Fixed data-1 (Initialized data)
64
Fixed data-2
65 to 82
Fixed data-1 (Initialized data)
83
Fixed data-2
84 to FF
Fixed data-1 (Initialized data)
14. 6E Page table
Note 1: 
If reading/writing data on pages 6E, set data: 06 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 6E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
of 63 to 6F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 63 to 6F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 1F
Fixed data-1 (Initialized data)
Page of 77
Display

Click on the first or last page to see other DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) service manuals if exist.