Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc47e-dcr-hc48-dcr-hc48e-sm4.pdf
Date

Sony DCR-HC47E / DCR-HC48 / DCR-HC48E (serv.man4) Service Manual ▷ View online

6-35
DCR-HC47E/HC48/HC48E_ADJ
14. Auto White Balance Standard Data Input 
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart
(AWB Adjustment Frame) (Note 3)
Adjustment Page
6F
Adjustment Address
2E to 31, E8 to EB
Note 1: Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Perform “13. Picture Frame Setting (AWB Adjustment
Frame)” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not,  perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “00”.
(Note 4)
4
Wait for 2 seconds.
5
6
01
43
Press PAUSE (Write) button.
6
6
01
41
Press PAUSE (Write) button.
(Note 5)
7
6
02
Check the data changes to
“01”.
Note 4: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: The adjustment data will be automatically input to page:
6F, address: 2E to 31, E8 to F3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
15. LV Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Subject
Clear chart
(AWB Adjustment Frame) (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
6F
Adjustment Address
2A, 2B
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Perform “13. Picture Frame Setting (AWB Adjustment
Frame)” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “00”.
(Note 4)
4
6
01
0D
Press PAUSE (Write) button.
(Note 5)
5
6
02
Check the data changes to
“01”.
Note 4: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: The adjustment data will be automatically input to page:
6F, address: 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
6-36
DCR-HC47E/HC48/HC48E_ADJ
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not,  perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
0
01
01
3
6
02
Check the data is “00”.
(Note 4)
4
0
10
06
5
F
44
2A
Press PAUSE (Write) button.
(6F)
6
F
45
Set the following data, and
press PAUSE (Write) button.
4E: NTSC model
AE: PAL model
7
F
46
5C
Press PAUSE (Write) button.
(6F)
8
F
47
98
Press PAUSE (Write) button.
(6F)
9
Place the C14 filter on the
lens.
10
0
10
00
11
6
01
47
Press PAUSE (Write) button.
12
6
01
45
Press PAUSE (Write) button.
(Note 5)
13
6
02
Check the data changes to
“01”.
Note 4: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Note 5: The adjustment data will be automatically input to page:
6F, address: 32 to 35, F4 to F7.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
3
Remove the C14 filter on the
lens.
16. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart
(AWB Adjustment Frame) (Note 3)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
32 to 35, 44 to 47, F4 to F7
Note 1: Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2: If reading/writing data on pages 6F, set data: 06 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 6F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3: Perform “13. Picture Frame Setting (AWB Adjustment
Frame)” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
(6F)
6-37
DCR-HC47E/HC48/HC48E_ADJ
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “AWB Adjustment Frame”.
If not, perform “13. Picture
Frame Setting (AWB
Adjustment Frame)”
2
6
02
Check the data is “00”.
(Note 4)
Auto white balance check
3
6
01
C1
Press PAUSE (Write) button.
4
6
02
Check the data changes to
“01”.
5
6
0C
Check the data is “00”.
6
6
01
00
Press PAUSE (Write) button.
InOut data check
7
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
8
6
01
4B
Press PAUSE (Write) button
9
6
02
Check the data changes to
“01”.
10
6
0C
Check the data is “00”.
11
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 4: If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
17. Auto White Balance Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Clear chart
(AWB Adjustment Frame) (Note 3)
Filter
ND filter 1.0, 0.4 and 0.1
Measuring Instrument
Adjusting remote commander
Specified Value
Data of page: 6, address: 0C is “00”
Note 1: Perform “Color Reproduction Adjustment” and “Auto
White Balance Adjustment” before this adjustment.
Note 2: Check that the data of page: 0, address: 10 is “00”.
Note 3: Perform “13. Picture Frame Setting (AWB Adjustment
Frame)” before this adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) WIDE SELECT .................................................................. 4:3
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADY SHOT (Menu setting) ..................................... OFF
6) FOCUS (Menu setting) .......................................... MANUAL
6-38
DCR-HC47E/HC48/HC48E_ADJ
18. Steady Shot Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03MA
Type B
ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified value
PITCH data: 2680 to 5080
YAW data: 2680 to 5080
Note 1: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Note 2: Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) ZOOM ..................................................................... TELE end
2) STEADY SHOT (Menu setting) ....................................... ON
Checking method:
Order Page Address Data
Procedure
  PITCH sensor output check (SE7002 of CD-672 board)
1
0
03
11
2
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the PITCH
data specified value.
  YAW sensor output check (SE7001 of CD-672 board)
3
0
03
12
4
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the YAW
data specified value.
5
0
03
00
  Steady shot operation check
6
Shake the set vertically and
horizontally to check that the
steady shot function operates
normally.
Page of 77
Display