DOWNLOAD Sony DCR-HC43 (serv.man3) Service Manual ↓ Size: 842.34 KB | Pages: 73 in PDF or view online for FREE

Model
DCR-HC43 (serv.man3)
Pages
73
Size
842.34 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-hc43-sm3.pdf
Date

Sony DCR-HC43 (serv.man3) Service Manual ▷ View online

6-22
DCR-HC43
8.
1F Page table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (“Refer to 1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (“Refer to 2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00, 01
Fixed data-1 (Initialized data)
02
Fixed data-2
03 to 19
Fixed data-1 (Initialized data)
1A
1B
Fixed data-2
1C to 70
Fixed data-1 (Initialized data)
71
Fixed data-2
72 to AB
Fixed data-1 (Initialized data)
AC
AD
Fixed data-2
AE to B1
Fixed data-1 (Initialized data)
B2
Fixed data-2
B3 to B6
Fixed data-1 (Initialized data)
B7
Fixed data-2
B8 to CB
Fixed data-1 (Initialized data)
CC
Fixed data-2
CD to E6
Fixed data-1 (Initialized data)
E7
E8
Fixed data-2
E9 to FF
Fixed data-1 (Initialized data)
7.
1E Page table
Note 1:
If reading/writing data on pages 1E, set data: 01 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 1E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00
Fixed data-2
01 to 06
Fixed data-1 (Initialized data)
07
08
Fixed data-2
09 to 17
Fixed data-1 (Initialized data)
18
19
1A
1B
1C
Fixed data-2
1D
1E
1F
20 to 91
Fixed data-1 (Initialized data)
92
Fixed data-2
93 to AC
Fixed data-1 (Initialized data)
AD
Fixed data-2
AE to C4
Fixed data-1 (Initialized data)
C5
C6
Fixed data-2
C7 to C9
Fixed data-1 (Initialized data)
CA
Fixed data-2
CB to D1
Fixed data-1 (Initialized data)
D2
D3
D4
Fixed data-2
D5
D6 to D8
Fixed data-1 (Initialized data)
D9
DA
DB
Fixed data-2
DC
DD to FF
Fixed data-1 (Initialized data)
6-23
DCR-HC43
2.
HALL Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
For detecting the position of lens iris and ND filter, adjust the hall
AMP gain and offset.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
13, 14, 17 to 19
Specified value
D4 to DC during IRIS CLOSE
24 to 2C during IRIS OPEN
Note 1:
Check that the data of page: 0, address: 10 is “00”
Note 2:
Check that the data of page: 6, address: 02 is “00”
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE button.
Note 3:
Check that the data of page: 0, address: 02 is “06”
Note 4:
The right two digits of the page: 1 displayed data of the
adjusting remote commander.
1 : 00 : XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
6D
Press PAUSE button. (Note 5)
3
6
02
Check the data changes to “01”.
4
6
01
00
Press PAUSE button.
Note 5:
The adjustment data will be automatically input to page:
F, address: 13, 14, 17 to 19.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
2
6
01
01
Press PAUSE button.
3
6
01
03
Press PAUSE button.
4
1
Check that the displayed data
(Note 4) during IRIS CLOSE
satisfied the specified value.
5
6
01
01
Press PAUSE button.
6
1
Check that the displayed data
(Note 4) during IRIS OPEN
satisfied the specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
0
01
00
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except “33MHz/27MHz Origin Oscillation Check”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1.
33MHz/27MHz Origin Oscillation Check
(VC-378 board) (33MHz: NTSC/27MHz: PAL)
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
R3209 (Pin rs of IC3201) on VC-
378 board
Measuring Instrument
Frequency counter
Specified value
f = 33000000 
±
 664 Hz (NTSC)
f = 27000000 
±
 542 Hz (PAL)
Note:
NTSC model: DCR-HC41/HC42/HC43
PAL model: DCR-HC39E/HC42E/HC43E
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-8
VC-378 board (SIDE A)
R3209
IC3201
6-24
DCR-HC43
3.
MR Adjustment 
RadarW
RadarW
RadarW
The inner focus lens MR adjustment is carried out automatically.
In whichever case, the focus will be deviated during auto focus-
ing/manual focusing.
Subject
Not required
Measurement Point
Adjusting remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified value 1
40 to C0
Specified value 2
03 to 78
Specified value 3
88 to FD
Note 1:
Perform the adjustment with the lens in horizontal state.
Note 2:
Perform “Flange Back Adjustment” after this adjustment.
Note 3:
Check that the data of page: 0, address: 10 is “00”.
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
BD
Press PAUSE button. (Note 5)
3
6
02
Check the data changes to
“01”.
4
F
5A
5B
5C
5D
5
F
5E
60
62
64
6
F
5F
61
63
65
Note 5:
The adjustment data will be automatically input to page:
F, address: 58, 5A to 65.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
0
01
00
Check that the data of each
address satisfied the specified
value 1.
Check that the data of each
address satisfied the specified
value 2.
Check that the data of each
address satisfied the specified
value 3.
6-25
DCR-HC43
4.
Flange Back and Zoom Lever Center Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
 (Using the minipattern box or flange
back adjustment jig)
The inner focus lens flange back adjustment is carried out auto-
matically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
minipattern box (Note 1) or flange
back adjustment jig
Measurement Point
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
11, 48 to 58
Specified value
Data of page: F, address: 57 is “00” to “0B”
Data of page: 6, address: 0C is “00”
Note 1:
Dark Siemens star chart.
Note 2:
Perform “HALL Adjustment” and “MR Adjustment”
before this adjustment.
Note 3:
Perform the adjustment with the lens in horizontal state.
Note 4:
Check that the data of page: 0, address: 10 is “00”.
Note 5:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 6:
Don't touch the zoom lever during adjustment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
E
FD
Set the bit value of bit4 is
“1”, and press PAUSE
button. (Note 7)
3
6
01
13
Press PAUSE button.
4
Wait for 2 seconds.
5
6
01
27
Press PAUSE button. (Note 8)
6
6
02
Check the data changes to “01”.
7
6
0C
Check the data is “00”.
8
F
57
Check the data is “00” to “0B”.
Note 7:
For the bit values, refer to “6-4. SERVICE MODE”, “4-
3. 3. Bit value discrimination”.
Note 8:
The adjustment data will be automatically input to page:
F, address: 11, 48 to 58.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
01
25
Press PAUSE button.
3
6
01
00
Press PAUSE button.
4
E
FD
Set the bit value of bit4 is
“0”, and press PAUSE
button. (Note 7)
5
0
01
00
6
Perform “Flange Back
Check”.
Preparation (Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note 9:
The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
±
 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-9
Preparation (Using the flange back adjustment jig)
(Luminance: about 300 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-10
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
Page of 73
Display

Click on the first or last page to see other DCR-HC43 (serv.man3) service manuals if exist.