DOWNLOAD Sony DCR-HC43 (serv.man3) Service Manual ↓ Size: 842.34 KB | Pages: 73 in PDF or view online for FREE

Model
DCR-HC43 (serv.man3)
Pages
73
Size
842.34 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-hc43-sm3.pdf
Date

Sony DCR-HC43 (serv.man3) Service Manual ▷ View online

6-10
DCR-HC43
6.
1A Page table
Note 1:
If reading/writing data on pages 1A, set data: 01 to page:
0, address: 10, and then select pages: A. By this data set-
ting, the pages 1A can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
7.
1B Page table
Note 1:
If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
5.
D Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
17
Fixed data-2
18 to 27
Fixed data-1 (Initialized data)
28
29
2A
Fixed data-2
2B
2C
2D
Fixed data-1 (Initialized data)
2E
2F
Fixed data-2
30
31, 32
Fixed data-1 (Initialized data)
33
Fixed data-2
34 to 44
Fixed data-1 (Initialized data)
45
Fixed data-2
46, 47
Fixed data-1 (Initialized data)
48
Fixed data-2
49
Fixed data-1 (Initialized data)
4A
4B
Fixed data-2
4C
Fixed data-1 (Initialized data)
4D
Fixed data-2
4E to 56
Fixed data-1 (Initialized data)
57
Fixed data-2
58 to 70
Fixed data-1 (Initialized data)
6-11
DCR-HC43
1-2-2.
Initialization of 8, C, 18, 1C Page Data
1.
Initializing of 8, C, 18, 1C Page Data
Note1:
If “Initialization of Pages 8, C, 18, 1C” is executed, all
data on pages 8, C, 18, 1C are initialized. (Only an indi-
vidual page cannot be initialized)
Note2 :
If the 8, C, 18, 1C page data has been initialized, the
following adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) Video system adjustments
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
18
Adjustment Address
00 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
81
Check that the data is “00”
4
3
80
0C
Press PAUSE button.
Check the data changes to
5
3
80
“1C”.
Perform “Modification of 8,
6
C, 18, 1C Page Data”
2.
Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data
of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 8, C, set data: 00 to page: 0,
address: 10, and then select pages 8, C.
3) If modification of data on pages 18, 1C, set data: 01 to page:
0, address: 10, and then select pages 8, C.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) If all areas were initialized, check that the data at the addresses
for adjustment are initial values (adjustment initial values)
listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification 8, C, 18, 1C page
data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
6-12
DCR-HC43
Address
Initial value
Remark
NTSC PAL
C0 to C2
Fixed data-1 (Initialized data)
C3
C4
C5
Fixed data-2
C6
C7
Fixed data-1 (Initialized data)
C8
C9
CA
CB
Fixed data-2
CC
CD
CE to D6
Fixed data-1 (Initialized data)
D7
Fixed data-2
D8 to DF
Fixed data-1 (Initialized data)
E0
Fixed data-2
E1
Fixed data-1 (Initialized data)
E2
E3
E4
E5
Fixed data-2
E6
E7
E8 to EF
Fixed data-1 (Initialized data)
F0
F1
Fixed data-2
F2 to F9
Fixed data-1 (Initialized data)
FA
FB
Fixed data-2
FC to FF
Fixed data-1 (Initialized data)
3.
8 Page table
Note 1:
Check that the data of page: 0, address: 10 is“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 29
Fixed data-1 (Initialized data)
2A
Fixed data-2
2B to 3F
Fixed data-1 (Initialized data)
40
41
Fixed data-2
42
Fixed data-1 (Initialized data)
43
44
Fixed data-2
45 to 4C
Fixed data-1 (Initialized data)
4D
Fixed data-2
4E to 79
Fixed data-1 (Initialized data)
7A
7B
Fixed data-2
7C to 81
Fixed data-1 (Initialized data)
82
Fixed data-2
83
Fixed data-1 (Initialized data)
84
85
86
87
Fixed data-2
88
89
8A to 8D
Fixed data-1 (Initialized data)
8E
8F
Fixed data-2
90 to A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
AA, AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to B2
Fixed data-1 (Initialized data)
B3
Fixed data-2
B4, B5
Fixed data-1 (Initialized data)
B6
Fixed data-2
B7
Fixed data-1 (Initialized data)
B8
B9
BA
Fixed data-2
BB
BC, BD
Fixed data-1 (Initialized data)
BE
BF
Fixed data-2
6-13
DCR-HC43
4.
C Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 18, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 18, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
11
00
00
12
00
00
Switching position adj.
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
E0
E0
CAP FG duty adj.
17 to 24
Fixed data-1 (Initialized data)
25
80
80
S VIDEO out Y level adj (2).
26
54
54
S VIDEO out chroma level adj (2).
27
3D
3D
28 to 3B
Fixed data-1 (Initialized data)
3C
3D
Fixed data-2
3E
3F
A0
A0
EVF automatic adj. (VCO adj.)
40
B0
B0
41
Fixed data-1 (Initialized data)
42
Fixed data-2
43
Fixed data-1 (Initialized data)
44
Fixed data-2
45
90
90
White balance adj. (EVF)
46
7C
7C
47
28
28
EVF automatic adj. (Contrast adj.)
48
49
Fixed data-2
4A, 4B
Fixed data-1 (Initialized data)
4C
4D
4E
Fixed data-2
4F
50
A0
A0
LCD automatic adj. (VCO adj.)
51
B0
B0
52
BC
BC
V-COM adj. (LCD)
53, 54
Fixed data-1 (Initialized data)
55
Fixed data-2
56
88
88
Transmissive mode white balans
57
71
71
adj. (LCD)
58
50
50
LCD automatic adj. (Contrast adj.)
59
Fixed data-2
5A to 5E
Fixed data-1 (Initialized data)
5F
Fixed data-2
60, 61
Fixed data-1 (Initialized data)
62
Fixd data-2
Address
Initial value
Remark
NTSC PAL
63
Fixed data-2
64, 65
Fixed data-1 (Initialized data)
66
67
Fixed data-2
68
69, 6A
Fixed data-1 (Initialized data)
6B
Fixed data-2
6C to 74
Fixed data-1 (Initialized data)
75
Fixed data-2
76 to 78
Fixed data-1 (Initialized data)
79
7A
Fixed data-2
7B
7D
7D
Reflective mode white balance adj.
7C
79
79
(LCD)
7D, 7E
Fixed data-1 (Initialized data)
7F
Fixed data-2
80
91
91
S VIDEO out Y level adj (1).
81
BA
BA
S VIDEO out chroma level adj (1).
82
85
85
83
00
00
84
00
00
85
00
00
86
00
00
IC4701 Automatic adj.
87
33
33
88
D2
D2
89
A8
A8
8A
23
23
8B to 90
Fixed data-1 (Initialized data)
91
92
93
94
Fixed data-2
95
96
97, 98
Fixed data-1 (Initialized data)
99
80
80
IC4701 Automatic adj.
9A to A0
Fixed data-1 (Initialized data)
A1
1F
1F
A2
1F
1F
IC4701 Automatic adj.
A3
1F
1F
A4
Fixed data-2
A5 to A8
Fixed data-1 (Initialized data)
A9
AA
AB
Fixed data-2
AC
AD to B1
Fixed data-1 (Initialized data)
Page of 73
Display

Click on the first or last page to see other DCR-HC43 (serv.man3) service manuals if exist.