Sony DCR-HC43 (serv.man3) Service Manual ▷ View online

6-18
DCR-HC43
4.
F Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
40
40
33MHz/27MHz origin osillation adj.
11
80
80
Flange back and zoom lever center
adj.
12
Fixed data-1 (Initialized data)
13
28
28
Hall adj.
14
70
70
15, 16
Fixed data-1 (Initialized data)
17
19
19
18
28
28
Hall adj.
19
D8
D8
1A, 1B
Fixed data-1 (Initialized data)
1C
00
00
1D
00
00
1E
00
00
1F
00
00
20
00
00
21
00
00
22
00
00
F No. & ND light quality standard
23
00
00
data input
24
00
00
25
00
00
26
00
00
27
00
00
28
00
00
29
00
00
2A
00
00
LV standard data input
2B
30
30
2C
A0
A0
MAX GAIN adj.
2D
Fixed data-1 (Initialized data)
2E
25
25
2F
00
00
Auto white balance
30
07
07
standard data input
31
00
00
32
15
15
33
00
00
Auto white balance adj.
34
0C
0C
35
00
00
36
Fixed data-1 (Initialized data)
37
45
48
Color reproduction adj.
38
Fixed data-1 (Initialized data)
39
2C
2E
Color reproduction adj.
3A to 3F
Fixed data-1 (Initialized data)
Address
Initial value
Remark
NTSC PAL
40
FC
FE
Color reproduction adj.
41
E7
E1
42, 43
Fixed data-1 (Initialized data)
44
2D
2C
45
60
C0
Auto white balance adj.
46
59
5B
47
00
80
48
37
37
49
1D
1D
4A
3B
3B
4B
7A
7A
4C
1C
1C
4D
1F
1F
4E
00
00
4F
00
00
Flange back and zoom lever center
50
00
00
adj.
51
00
00
52
75
75
53
19
19
54
00
00
55
4A
4A
56
00
00
57
00
00
58
00
00
MR adj./Flange back and zoom
lever center adj.
59
Fixed data-1 (Initialized data)
5A
80
80
5B
80
80
5C
80
80
5D
80
80
5E
40
40
5F
C0
C0
MR adj.
60
40
40
61
C0
C0
62
40
40
63
C0
C0
64
40
40
65
C0
C0
66 to 70
Fixed data-1 (Initialized data)
72
73
Fixed data-2
74, 75
Fixed data-1 (Initialized data)
76
5C
4D
77
00
00
78
47
3C
Mechanical shutter adj.
79
00
00
7A
3E
34
6-19
DCR-HC43
Address
Initial value
Remark
NTSC PAL
7B
00
00
7C
38
2F
7D
00
00
7E
28
20
7F
00
00
80
62
60
81
7A
75
82
81
7B
83
7C
76
Mechanical shutter adj.
84
6A
63
85
1E
1E
86
80
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
80
8C to 93
Fixed data-1 (Initialized data)
94
95
Fixed data-2
96 to 98
Fixed data-1 (Initialized data)
99
9A
Fixed data-2
9B to 9D
Fixed data-1 (Initialized data)
9E
Fixed data-2
9F to AC
Fixed data-1 (Initialized data)
AD
AE
Fixed data-2
AF to BF
Fixed data-1 (Initialized data)
C0
C1
Fixed data-2
C2 to DB
Fixed data-1 (Initialized data)
DC
DD
Fixed data-2
DE to E2
Fixed data-1 (Initialized data)
E3
E4
Fixed data-2
E5 to F4
Fixed data-1 (Initialized data)
F5
Fixed data-2
F6, F7
Fixed data-1 (Initialized data)
F8
F9
FA
Fixed data-2
FB
FC to FF
Fixed data-1 (Initialized data)
F Page table
6-20
DCR-HC43
Address
Initial value
Remark
NTSC PAL
F7
00
00
F8
15
15
F9
00
00
FA
0C
0C
FB
00
00
Auto white balance adj.
FC
15
15
FD
00
00
FE
0C
0C
 FF
00
00
5.
14 Page table
Note 1:
If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 2C
Fixed data-1 (Initialized data)
2D
Fixed data-2
2E to 31
Fixed data-1 (Initialized data)
32
Fixed data-2
33, 34
Fixed data-1 (Initialized data)
35
Fixed data-2
36 to 3F
Fixed data-1 (Initialized data)
40
41
42
43
44
Fixed data-2
45
46
47
48 to 4E
Fixed data-1 (Initialized data)
4F
Fixed data-2
50 to D5
Fixed data-1 (Initialized data)
D6
Fixed data-2
D7 to DA
Fixed data-1 (Initialized data)
DB
Fixed data-2
DC, DD
Fixed data-1 (Initialized data)
DE
Fixed data-2
DF to E7
Fixed data-1 (Initialized data)
E8
25
25
E9
00
00
EA
07
07
EB
00
00
EC
25
25
ED
00
00
Auto white balance
EE
07
07
standard data input
EF
00
00
F0
25
25
F1
00
00
F2
07
07
F3
00
00
F4
15
15
F5
00
00
Auto white balance adj.
F6
0C
0C
6-21
DCR-HC43
Address
Initial value
Remark
NTSC PAL
89
00
00
Emergency memory address
8A
00
00
(Camera section)
8B to 9E
Fixed data-1 (Initialized data)
9F
Fixed data-2
A0 to DC
Fixed data-1 (Initialized data)
DD
Fixed data-2
DE to FF
Fixed data-1 (Initialized data)
6.
19 Page table
Note 1:
If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 2F
Fixed data-1 (Initialized data)
30
Fixed data-2
31 to 35
Fixed data-1 (Initialized data)
36
Fixed data-2
37 to 2F
Fixed data-1 (Initialized data)
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
Fixed data-2
61
62
63
64
65
66
67
68
69
6A
6B
6C to 76
Fixed data-1 (Initialized data)
77
78
Fixed data-2
79, 7A
Fixed data-1 (Initialized data)
7B
Fixed data-2
7C, 7D
Fixed data-1 (Initialized data)
7E
Fixed data-2
7F to 86
Fixed data-1 (Initialized data)
87
00
00
Emergency memory address
88
00
00
(Camera section)
Page of 73
Display

Click on the first or last page to see other DCR-HC43 (serv.man3) service manuals if exist.