DOWNLOAD Sony DCR-HC43 (serv.man3) Service Manual ↓ Size: 842.34 KB | Pages: 73 in PDF or view online for FREE

Model
DCR-HC43 (serv.man3)
Pages
73
Size
842.34 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-hc43-sm3.pdf
Date

Sony DCR-HC43 (serv.man3) Service Manual ▷ View online

6-34
DCR-HC43
15. Auto White Balance Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance reference at 3200K, and adjust the nor-
mal coefficient of the light value.
Subject
Clear chart (All white frame)
Adjustment Page
F
14
Adjustment Address
2E to 31
E8 to F3
Note 1:
Perform “Color Reproduction Adjustment” before this
adjustment.
Note 2:
If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) WIDE SELECT ................................................................. 4: 3
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”
2
0
01
01
3
Wait for 2 seconds.
4
6
01
11
Press PAUSE button.
5
6
01
0B
Press PAUSE button. (Note 4)
6
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 2E to 31 and page: 14, address: E8 to F3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
16. LV Standard Data Input 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the normal coefficient of the light value at 3200K.
Subject
Clear chart (All white frame)
Measurement Point
Displayed data of page: 1 (Note 4)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
2A, 2B
Specified Value
0FE0 to 1020
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Note 4:
Check that the data of page: 0, address: 02 is “06”.
Note 5:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) WIDE SELECT ................................................................. 4: 3
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”
2
0
01
01
3
Wait for 6 seconds.
4
6
01
0D
Press PAUSE button. (Note 6)
5
6
02
Check the data changes to
“01”.
6
0
03
1E
7
1
Check that the displayed data
(Note 5) satisfied the
specified value.
Note 6:
The adjustment data will be automatically input to page:
F, address: 2A, 2B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
03
00
3
0
01
00
6-35
DCR-HC43
18. Auto White Balance Check 
RadarW
RadarW
RadarW
Subject
Clear chart (All white frame)
Filter
ND filter 1.0, 0.4 and 0.1
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Specified Value
8000 to 8BC0
Note 1:
Perform “Auto White Balance Adjustment” before this
adjustment.
Note 2:
Check that the data of page: 0, address: 10 is “00”.
Note 3:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) WIDE SELECT ................................................................. 4: 3
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”
OUTDOOR white balance check
2
6
01
4F
Press PAUSE button.
3
0
03
33
4
1
Check that bit15 of the
display data (Note 3) is “1”.
(Note 4)
5
6
01
00
Press PAUSE button.
INDOOR white balance check
6
6
01
0F
Press PAUSE button.
7
1
Check that bit15 of the
display data (Note 3) is “1”.
(Note 4)
8
6
01
00
Press PAUSE button.
InOut data check
9
Place the ND filter 1.5 (1.0 +
0.4 + 0.1) on the lens.
10
0
03
06
11
1
Check that the displayed data
(Note 3) satisfied the
specified value.
12
Remove the ND filter 1.5
(1.0 + 0.4 + 0.1) on the lens.
Note 4:
When bit15 of the display data is “1”, the display data is
“8000” to “FFFF”.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
17. Auto White Balance Adjustment 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility
will be poor.
Subject
Clear chart (All white frame)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note 1:
Perform “F No. & ND Light Quality Standard Data In-
put” and “Auto White Balance Standard Data Input” be-
fore this adjustment.
Note 2:
If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 3:
Check that the data of page: 6, address: 02 is “00”. If
not, select page: 6, address: 01, set data: 00, and press
PAUSE button.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu setting) .......................................... MANUAL
6) WIDE SELECT ................................................................. 4: 3
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “All White Frame”. If not,
perform “14. Picture Frame
Setting (All White Frame)”
2
Place the C14 filter on the
lens.
3
0
01
01
4
F
44
2C
Press PAUSE button.
5
F
45
E0
Press PAUSE button.
6
F
46
59
Press PAUSE button.
7
F
47
00
Press PAUSE button.
8
6
01
83
Press PAUSE button.
9
6
01
81
Press PAUSE button. (Note 4)
10
6
02
Check the data changes to
“01”.
Note 4:
The adjustment data will be automatically input to page:
F, address: 32 to 35, 44 to 47 and page: 14, address: F4
to FF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
0
01
00
3
Remove the C14 filter on the
lens.
6-36
DCR-HC43
19. Steady Shot Check 
RadarW
RadarW
RadarW
RadarW
RadarW
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03MA
Type B
ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified value
PITCH data: 2680 to 5080
YAW data: 2680 to 5080
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1 : XX : XX
Displayed data
Note 2:
 Check that the data of page: 0, address: 10 is “00”.
Switch setting
1) ZOOM ..................................................................... TELE end
2) STEADY SHOT (Menu setting) ....................................... ON
Checking method:
Order Page Address Data
Procedure
  PITCH sensor output check (SE601 of SI-042 board)
1
0
03
11
2
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the PITCH
data specified value.
  YAW sensor output check (SE602 of SI-042 board)
3
0
03
12
4
1
With the set in still state,
check that the displayed data
(Note 1) satisfies the YAW
data specified value.
5
0
03
00
  Steady shot operation check
6
Shake the set vertically and
horizontally to check that the
steady shot function operates
normally.
6-37
DCR-HC43
1-4.
ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENTS
Before perform the electronic viewfinder system adjustments,
check that the data of page: 0, address: 10 is “00”. If not, select
page: 0, address: 10, and set the data “00”.
Note 1:
Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 2:
Perform the following data setting before the viewfinder
system adjustments.
1) Select page: 3, address: C4, and set data: 67.
2) Select page: 3, address: C5, and set data: 01.
Reset the data after completing adjustment.
1) Select page: 3, address: C4, and set data: 00.
2) Select page: 3, address: C5, and set data: 00.
1.
EVF Automatic Adjustment (LB-109 board)
RadarW
RadarW
RadarW
This adjustment does the following items automatically.
  VCO Adjustment
  Contrast Adjustment
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Adjustment Page
C
Adjustment Address
3F, 40 (VCO Adjustment)
47 (Contrast Adjustment)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
NTSC model: DCR-HC41/HC42/HC43
PAL model: DCR-HC39E/HC42E/HC43E
Switch setting
WIDE SELECT ........................................................................ 4: 3
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
71
00
Press PAUSE button.
3
3
01
5A
Press PAUSE button. (Note 3)
4
3
02
Check the data changes to “00”.
5
3
03
Check the data is “00”. (Note 4)
6
C
3F
Read the data and this data is
named D
3F
.
7
Convert D
3F
 to decimal
notation, and obtain D
3F
’.
(Note 5)
8
Calculate D
40
’ using
following equations.
(decimal calculation)
D
40
’ = D
3F
’ + 10 (NTSC model)
D
40
’ = D
3F
’ – 10 (PAL model)
9
Convert D
40
’ to a hexadeci-
mal number, and obtain D
40
.
(Note 5)
10
C
40
D
40
Press PAUSE button.
11
C
71
41
Press PAUSE button.
12
0
01
00
Note 3:
The adjustment data will be automatically input to page:
C, address: 3F and 47.
Note 4:
 If the data change to “01”, adjustment has error. Contents
of error is written into page: 3, address: C6. See the fol-
lowing table.
Note 5:
 Refer to table 6-4-1. “Hexadecimal-decimal conversion
table”.
Data of page: 3, address: C6
Contents of error
5E
VCO adjustment error
61
Contrast adjustment error
Page of 73
Display

Click on the first or last page to see other DCR-HC43 (serv.man3) service manuals if exist.