DOWNLOAD Sony DCR-HC21 (serv.man2) Service Manual ↓ Size: 1.11 MB | Pages: 89 in PDF or view online for FREE

Model
DCR-HC21 (serv.man2)
Pages
89
Size
1.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-hc21-sm2.pdf
Date

Sony DCR-HC21 (serv.man2) Service Manual ▷ View online

6-18
DCR-HC21
Address
Initial value
Remark
NTSC PAL
44
3A
3A
Flange back adj.
45
74
74
46
3F
3F
47
2C
2C
48
17
17
49
4A
4A
4A
00
00
4B
00
00
4C
00
00
4D
00
00
4E
4F
4F
4F
19
19
50
00
00
51
30
30
52
04
04
53
00
00
54
00
00
55 to 57
Fixed data-1 (Initialized data)
58
59
Fixed data-2
5A
FF
FF
Optical axis adj.
5B to 67
Fixed data-1 (Initialized data)
68
00
00
Mechanical shutter adj.
69
00
00
6A
00
00
6B
00
00
6C
00
00
6D
00
00
6E
00
00
6F
00
00
70
00
00
71
00
00
72
00
00
73
00
00
74
00
00
75
00
00
76
00
00
77
00
00
78
00
00
79
00
00
7A
00
00
7B
00
00
7C
00
00
7D
00
00
Address
Initial value
Remark
NTSC PAL
7E to 8B
Fixed data-1 (Initialized data)
8C
8D
8E
8F
Fixed data-2
90
91, 92
Fixed data-1 (Initialized data)
93
94
95
Fixed data-2
96
97, 98
Fixed data-1 (Initialized data)
99
Fixed data-2
9A to A8
Fixed data-1 (Initialized data)
A9
AA
AB
AC
AD
Fixed data-2
AE
AF
B0
B1 to EA
Fixed data-1 (Initialized data)
EB
Fixed data-2
EC, ED
Fixed data-1 (Initialized data)
EE
Fixed data-2
EF to FA
Fixed data-1 (Initialized data)
FB
Fixed data-2
FC to FF
Fixed data-1 (Initialized data)
F Page Table
6-19
DCR-HC21
5.
1F Page Table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 07
Fixed data-1 (Initialized data)
08
Fixed data-2
09 to 59
Fixed data-1 (Initialized data)
5A
00
00
Emergency memory address
5B
00
00
(Camera section)
5C
00
00
5D
00
00
5E to FF
Fixed data-1 (Initialized data)
6-20
DCR-HC21
1-3.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 19,
1A, 1B, 1C, 1E, 1F PAGE DATA (MS model)
Note 1:
If reading/writing data on pages 18, 19, 1A, 1B, 1C, 1E,
1F, set data: 01 to page: 0, address: 10, and then select
pages: 8, 9, A, B, C, E, F.
By this data setting, the pages 18, 19, 1A, 1B, 1C, 1E,
1F, can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
MS model: DCR-HC32/HC32E/HC33/HC33E
1-3-1.
Initialization of A, B, D, 1A, 1B Page Data
Note:
Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of A, B, D, 1A, 1B Page Data
Note 1:
If the A, B, D, 1A, 1B page data has been initialized, the
following adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Note 2:
NTSC model: DCR-HC32/HC33
PAL model: DCR-HC32E/HC33E
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
B
Adjustment Address
00 to FF
Adjustment Page
D
Adjustment Address
10 to 70
Adjustment Page
1A
Adjustment Address
00 to FF
Adjustment Page
1B
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
04
Set the following data
20: NTSC model
21: PAL model
Set the following data
20: Initializing A page
21: Initializing B page
22: Initializing D page
23: Initializing 1A page
24: Initializing 1B page
4
7
01
25: Initializing A and 1A
page
26: Initializing B and 1B
page
28: Initializing A, B, D, 1A
and 1B page
5
7
00
01
Press PAUSE button.
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
B, D, 1A, 1B Page Data”
2.
Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages A, B, D, set data: 00 to page:
0, address: 10, and then select pages A, B, D.
3) If modification of data on pages 1A, 1B, set data: 01 to page:
0, address: 10, and then select pages A, B.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, B, D, 1A, 1B
page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
Note 2:
If following symptoms occur after completing of the
“Modification A, B, D, 1A, 1B page data”, check that
the data of the “Fixed data-2” address of A, B, D, 1A, 1B
page are same as those of same model of same destina-
tion.
1) The power is shut off so that unit cannot operate.
6-21
DCR-HC21
3.
A Page table
Note 1:
Check that the data of page: 0, address: 10 is“00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 17
Fixed data-1 (Initialized data)
18
Fixed data-2
19 to 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to 60
Fixed data-1 (Initialized data)
61
62
Fixed data-2
63
64 to 8F
Fixed data-1 (Initialized data)
90
E0
DD
Touch panel adj
91
1D
1C
92
D4
C7
93
24
2A
94 to CF
Fixed data-1 (Initialized data)
D0
D1
Fixed data-2
D2
D3, D4
Fixed data-1 (Initialized data)
D5
Fixed data-2
D6
Fixed data-1 (Initialized data)
D7
Fixed data-2
D8
Fixed data-1 (Initialized data)
D9
Fixed data-2
DA to F0
Fixed data-1 (Initialized data)
F1
F2
Fixed data-2
F3
F4 to FF
Fixed data-1 (Initialized data)
4.
B Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
5.
D Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
17
Fixed data-2
18 to 27
Fixed data-1 (Initialized data)
28
29
2A
Fixed data-2
2B
2C
2D
Fixed data-1 (Initialized data)
2E
2F
Fixed data-2
30
31, 32
Fixed data-1 (Initialized data)
33
Fixed data-2
34 to 44
Fixed data-1 (Initialized data)
45
Fixed data-2
46, 47
Fixed data-1 (Initialized data)
48
Fixed data-2
49
Fixed data-1 (Initialized data)
4A
4B
Fixed data-2
4C
Fixed data-1 (Initialized data)
4D
4E
Fixed data-2
4F to 56
Fixed data-1 (Initialized data)
57
Fixed data-2
58 to 70
Fixed data-1 (Initialized data)
Page of 89
Display

Click on the first or last page to see other DCR-HC21 (serv.man2) service manuals if exist.