DOWNLOAD Sony DCR-HC21 (serv.man2) Service Manual ↓ Size: 1.11 MB | Pages: 89 in PDF or view online for FREE

Model
DCR-HC21 (serv.man2)
Pages
89
Size
1.11 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-hc21-sm2.pdf
Date

Sony DCR-HC21 (serv.man2) Service Manual ▷ View online

6-14
DCR-HC21
3.
8 Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 3F
Fixed data-1 (Initialized data)
40
Fixed data-2
41 to 4C
Fixed data-1 (Initialized data)
4D
Fixed data-2
4E to 79
Fixed data-1 (Initialized data)
7A
7B
Fixed data-2
7C to 89
Fixed data-1 (Initialized data)
8A
Fixed data-2
8B to 8D
Fixed data-1 (Initialized data)
8E
8F
Fixed data-2
90 to B2
Fixed data-1 (Initialized data)
B3
Fixed data-2
B4 to BE
Fixed data-1 (Initialized data)
BF
Fixed data-2
C0 to C3
Fixed data-1 (Initialized data)
C4
C5
C6
Fixed data-2
C7
C8
C9
Fixed data-1 (Initialized data)
CA
CB
Fixed data-2
CC to D5
Fixed data-1 (Initialized data)
D6
D7
Fixed data-2
D8 to FF
Fixed data-1 (Initialized data)
4.
C Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
Switching position adj.
11
00
00
12
00
00
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
E0
E0
CAP FG duty adj.
17 to 24
Fixed data-1 (Initialized data)
25
80
80
S VIDEO OUT Y level adj.
26
90
90
S VIDEO OUT chroma level adj.
27
65
65
28 to 3B
Fixed data-1 (Initialized data)
3C
Fixed data-2
3D, 3E
Fixed data-1 (Initialized data)
3F
6C
6C
EVF automatic adj. (VCO adj.)
40
90
90
41 to 44
Fixed data-1 (Initialized data)
45
46
Fixed data-2
47
28
28
EVF automatic adj. (Contrast adj.)
48 to 4C
Fixed data-1 (Initialized data)
4D
4E
4F
Fixed data-2
50
6C
6C
LCD automatic adj. (VCO adj.)
51
90
90
52
BC
BC
V-COM adj. (LCD)
53, 54
Fixed data-1 (Initialized data)
55
Fixed data-2
56
7D
7D
Transmissive mode white balans
57
73
73
adj. (LCD)
58
52
52
LCD automatic adj. (Contrast adj.)
59 to 5E
Fixed data-1 (Initialized data)
5F
Fixed data-2
60 to 65
Fixed data-1 (Initialized data)
66
67
68
Fixed data-2
69 to 74
Fixed data-1 (Initialized data)
75
Fixed data-2
76 to A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
6-15
DCR-HC21
Address
Initial value
Remark
NTSC PAL
AA
Fixed data-1 (Initialized data)
AB
AC
Fixed data-2
AD to AF
Fixed data-1 (Initialized data)
B0
B1
Fixed data-2
B2
B3
Fixed data-1 (Initialized data)
B4
B5
Fixed data-2
B6 to D1
Fixed data-1 (Initialized data)
D2
D3
Fixed data-2
D4
D5 to DD
Fixed data-1 (Initialized data)
DE
DF
Fixed data-2
E0 to E4
Fixed data-1 (Initialized data)
E5
00
00
E6
00
00
Node unique ID No. Input
E7
00
00
E8 to F3
Fixed data-1 (Initialized data)
F4
00
00
Emergency memory address
F5
00
00
(Mechanism section)
F6
00
00
F7
00
00
F8
00
00
F9
00
00
FA
00
00
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
5.
1C Page Table
Note 1:
If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to B2
Fixed data-1 (Initialized data)
B3
00
00
SD error rate check (LP)
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BC
00
00
BD
00
00
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to E5
Fixed data-1 (Initialized data)
E6
Fixed data-2
E7 to E9
Fixed data-1 (Initialized data)
EA
EB
Fixed data-2
EC to EE
Fixed data-1 (Initialized data)
EF
F0
Fixed data-2
F1 to FF
Fixed data-1 (Initialized data)
C Page Table
6-16
DCR-HC21
1-2-3.
Initialization of E, F, 1F Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of E, F, 1F Page Data
Note 1:
If “Initialization of Pages E, F, 1F” is executed, all data
on pages E, F, 1F are initialized. (Only an individual page
cannot be initialized)
Note 2:
If the E, F, 1F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of E, F, 1F page data
2) Camera system adjustments
Note 3:
NTSC model: DCR-HC21/HC32/HC33
PAL model: DCR-HC17E/HC19E/HC21E/HC22E/
HC32E/HC33E
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
6
01
Set the following data, and
press PAUSE button.
2D: NTSC model
2F: PAL model
4
6
03
FF
Press PAUSE button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE button.
7
Perform “Modification of E,
F, 1F Page Data”
2.
Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages F. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification E, F, 1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
4
Perform “36MHz Origin
Oscillation Adjustment” of
CAMERA SYSTEM
ADJUSTMENTS.
6-17
DCR-HC21
3.
E Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 11
Fixed data-1 (Initialized data)
12
Fixed data-2
13, 14
Fixed data-1 (Initialized data)
15
16
Fixed data-2
17
18 to 34
Fixed data-1 (Initialized data)
35
Fixed data-2
36 to 41
Fixed data-1 (Initialized data)
42
43
44
45
46
Fixed data-2
47
48
49
4A
4B
Fixed data-1 (Initialized data)
4C
Fixed data-2
4D to 55
Fixed data-1 (Initialized data)
56
57
Fixed data-2
58 to 68
Fixed data-1 (Initialized data)
69
Fixed data-2
6A to 8D
Fixed data-1 (Initialized data)
8E
8F
Fixed data-2
90
Fixed data-1 (Initialized data)
91
Fixed data-2
92 to A3
Fixed data-1 (Initialized data)
A4
Fixed data-2
A5 to BD
Fixed data-1 (Initialized data)
BE
Fixed data-2
BF to DA
Fixed data-1 (Initialized data)
DB
Fixed data-2
DC to E4
Fixed data-1 (Initialized data)
E5
Fixed data-2
E6 to FF
Fixed data-1 (Initialized data)
4. F Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
80
80
36MHz origin osillation adj.
11
Fixed data-1 (Initialized data)
12
50
50
Hall adj.
13
50
50
14
89
89
15
00
00
16
17
17
17
00
00
18
00
00
19
A8
A8
MAX GAIN adj.
1A
36
36
LV standard data input
1B
00
00
1C
00
00
F No. standard data input
1D
00
00
1E
00
00
1F
00
00
20
00
00
21
00
00
22
00
00
23
00
00
24 to 29
Fixed data-1 (Initialized data)
2A
27
27
Auto white balance standard data
2B
00
00
input
2C
08
08
2D
00
00
2E
18
18
Auto white balance adj.
2F
00
00
30
0E
0E
31
00
00
32
Fixed data-1 (Initialized data)
33
48
47
Color reproduction adj.
34
Fixed data-1 (Initialized data)
35
2A
2B
Color reproduction adj.
36 to 39
Fixed data-1 (Initialized data)
3A
00
FF
Color reproduction adj.
3B
EF
ED
3C, 3D
Fixed data-1 (Initialized data)
3E
2A
2A
Auto white balance adj.
3F
00
C0
40
5D
5C
41
00
00
42, 43
Fixed data-1 (Initialized data)
Page of 89
Display

Click on the first or last page to see other DCR-HC21 (serv.man2) service manuals if exist.