5-37
5. C OUT Level Adjustment (VC-214 board)
Set the chroma signal output level. (Adjust the D/A converter out
put level of IC151.)
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
terminal (75
 terminated )
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
6B
Specified Value
A=300 ± 5mV
Note :
 Insert the plug into the S video terminal.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 61, and set data: 30.
4)
Select page: F, address: 6B, change the data and set the burst
level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 6, address: 61, and set data: 10.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
6. RP Filter f
0
 Adjustment (VC-214 board)
Adjust the LPF of the playback RF amplifier (IC001).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 9 of CN910 (RF AGC OUT)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
6E
Specified Value
A= Minimum
Connection:
1)
Input a 14.2MHz, 400mVp-p CW signal to Pin 7 of CN910
(RF AGC IN).
Transistor : General NPN transistor (2SC403, etc)
47 
 resistor :
1-249-401-11
1 k
 resistor :
1-249-417-11
15 k
 resistor :
1-249-431-11
0.01 
µ
F capacitor : 1-101-004-00
Fig. 5-3-10.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 35, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 6E, change the data and minimize the
14.2 MHz signal level (A).
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
H
A
Signal 
generator
14.2 MHz 400 mVp-p
0.01 
µ
F
47 
15 k
1 k
RFU DC OUT jack 
on PJ-92 board 
(4.75 V)
Pin 
7
 of CN910
(RF AGC IN)
Pin 
8
 of CN910
(REG GND)
0.01 
µ
F  
A
14.2MHz
Fig. 5-3-9.
Fig. 5-3-11.
5-38
A
0.18 
µ
sec
Fig. 5-3-12.
7. REC Y Current Adjustment (VC-214 board)
Adjust the Y FM signal recording current.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
73  to 7A
Specified Value
A=185 ± 5mV
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
Adjusting method:
1)
Insert a tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 7C, after note down the data , set data:
00, and press the PAUSE button of the adjustment remote
commander.
4)
Select page: F, address: 85, after note down the data , set data:
00, and press the PAUSE button of the adjustment remote
commander.
5)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: F, address: 74 , change the data and set the Y signal
level (A) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Select page: F, address: 74 , and read the data (D
74
).
9)
Calculate the adjustment data from the following equations,
and input each adjustment address.
Address: 73
D
73
  = D
74
Address: 75
D
75
  = D
74
Address: 76
D
76
  = D
74
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
10) Write the following data in page: F, address: 77  to  7A .
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
11) Select page: F, address: 7C, set the data noted down at step 3),
and press the PAUSE button of the adjustment remote
commander.
12) Select page: F, address: 85, set the data noted down at step 4),
and press the PAUSE button of the adjustment remote
commander.
13) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
14) Select page: 0, address: 01, and set data: 00.
Address
77
78
79
7A
Data
63
6B
63
6B
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
5-39
A
0.67
µ
sec
Center of the luminace line width
Center of the luminace line width
Fig. 5-3-13.
VC-214 BOARD
IC202
1
44
132
89
176
133
45
88
IC001
12
1
25 36
13
48
24
37
C085
8. REC L Level Adjustment (VC-214 board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording / playback
image.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
7B to 84
Specified Value
A=11.0 ± 0.7mV
Note:
Do not insert any plug into the AUDIO (R) terminal.
Connection:
1)
Remove C085 (0.01 
µ
F, Pin !§ of IC202).
Note:
After completing “REC L Level Adjustment” and “REC C
Current Adjustment”, replace C085 with new parts (1-182-970-
11 CERAMIC CHIP 0.01 
µ
F 10% 25V).
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
Adjusting method:
1)
Insert Hi8 ME tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 7B, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: F, address: 85, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5)
Select page: F, address: 7C, change the data and set the REC
AFM signal level (A) to the specified value.
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: F, address: 7C, read the data (D
7C
).
8)
Convert D
7C
 to decimal notation, and obtain D
7C
'. (Refer to Table
5-4-1. “Hexadecimal-decimal conversion table” of “5-4. Service
Mode”.)
9)
Calculate the adjustment data (decimal) from the following
equations (decimal calculation), convert it to a hexadecimal
number, and input each adjustment address.
Address: 7B
D
7B
' = D
7C
'
Address: 7D
D
7D
' = D
7C
'
Address: 7E
D
7E
' = D
7C
'
Address: 7F
D
7F
' = D
7C
' –68
Address: 80
D
80
' = D
7C
' –68
Address: 81
D
81
' = D
7C
' –68
Address: 82
D
82
' = D
7C
' –68
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
10) Write the following data (hexadecimal) in page: F, address: 83
to 84.
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
11) Select page: 0, address: 01, and set data: 00.
12) Perform “REC C Current Adjustment”.
Address
83
84
Data
96
96
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
5-40
1.35 
µ
sec
Center of the luminance line width 
Fig. 5-3-14.
9. REC C Current Adjustment (VC-214 board)
Set the recording current levels of the REC Chroma signal. If it is
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noises will increase and white modulation noises
will be produced.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
85
Specified Value
A=35.7 ± 1.3mV
Connection:
1)
Remove C085 (0.01 
µ
F, Pin !§ of IC202).
Note:
After completing “REC L Level Adjustment” and “REC C
Current Adjustment”, replace C085 with new parts (1-162-970-
11 CERAMIC CHIP 0.01 
µ
F 10% 25V).
2)
Connect Pin $∞ of IC001 and GND with a 0.01F capacitor.
0.01 
µ
F capacitor: 1-101-004-00
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
Adjusting method:
1)
Insert a tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 61, and set data: 30.
5)
Select page: F, address: DE, after note down the data, set data:
00, and press the PAUSE button of the adjustment remote
commander.
6)
Select page: F, address: 85, change the data and set the REC
chroma signal level (A) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Select page: F, address: DE, set the data noted down at step 5),
and press the PAUSE button of the adjustment remote
commander.
9)
Select page: 6, address: 61, and set data: 10.
10) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
11) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
Page of 127