Sony CCD-TR913E / CCD-TR950E Service Manual ▷ View online
5-37
5. C OUT Level Adjustment (VC-214 board)
Set the chroma signal output level. (Adjust the D/A converter out
put level of IC151.)
put level of IC151.)
Mode
VTR stop
Signal
No signal
Measurement Point
Chroma signal terminal of S VIDEO
terminal (75
terminal (75
Ω
terminated )
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
6B
Specified Value
A=300 ± 5mV
Note :
Insert the plug into the S video terminal.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: 6, address: 61, and set data: 30.
4)
Select page: F, address: 6B, change the data and set the burst
level (A) to the specified value.
level (A) to the specified value.
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 6, address: 61, and set data: 10.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
8)
Select page: 0, address: 01, and set data: 00.
6. RP Filter f
0
Adjustment (VC-214 board)
Adjust the LPF of the playback RF amplifier (IC001).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 9 of CN910 (RF AGC OUT)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
6E
Specified Value
A= Minimum
Connection:
1)
1)
Input a 14.2MHz, 400mVp-p CW signal to Pin 7 of CN910
(RF AGC IN).
(RF AGC IN).
Transistor : General NPN transistor (2SC403, etc)
47
47
Ω
resistor :
1-249-401-11
1 k
Ω
resistor :
1-249-417-11
15 k
Ω
resistor :
1-249-431-11
0.01
µ
F capacitor : 1-101-004-00
Fig. 5-3-10.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 35, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
3)
Select page: F, address: 6E, change the data and minimize the
14.2 MHz signal level (A).
14.2 MHz signal level (A).
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
H
A
Signal
generator
generator
14.2 MHz 400 mVp-p
0.01
µ
F
47
Ω
15 k
Ω
1 k
Ω
RFU DC OUT jack
on PJ-92 board
(4.75 V)
on PJ-92 board
(4.75 V)
Pin
7
of CN910
(RF AGC IN)
Pin
8
of CN910
(REG GND)
0.01
µ
F
A
14.2MHz
Fig. 5-3-9.
Fig. 5-3-11.
5-38
A
0.18
µ
sec
Fig. 5-3-12.
7. REC Y Current Adjustment (VC-214 board)
Adjust the Y FM signal recording current.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
73 to 7A
Specified Value
A=185 ± 5mV
Preparations only for the model without REC switch:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
remote commander of 8mm VCR.)
Adjusting method:
1)
1)
Insert a tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 7C, after note down the data , set data:
00, and press the PAUSE button of the adjustment remote
commander.
00, and press the PAUSE button of the adjustment remote
commander.
4)
Select page: F, address: 85, after note down the data , set data:
00, and press the PAUSE button of the adjustment remote
commander.
00, and press the PAUSE button of the adjustment remote
commander.
5)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
6)
Select page: F, address: 74 , change the data and set the Y signal
level (A) to the specified value.
level (A) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Select page: F, address: 74 , and read the data (D
74
).
9)
Calculate the adjustment data from the following equations,
and input each adjustment address.
and input each adjustment address.
Address: 73
D
73
= D
74
Address: 75
D
75
= D
74
Address: 76
D
76
= D
74
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
the adjustment remote commander.
10) Write the following data in page: F, address: 77 to 7A .
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
the adjustment remote commander.
11) Select page: F, address: 7C, set the data noted down at step 3),
and press the PAUSE button of the adjustment remote
commander.
commander.
12) Select page: F, address: 85, set the data noted down at step 4),
and press the PAUSE button of the adjustment remote
commander.
commander.
13) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
14) Select page: 0, address: 01, and set data: 00.
Address
77
78
79
7A
Data
63
6B
63
6B
Processing after completed adjustment only for the model
without REC switch:
1)
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
5-39
A
0.67
µ
sec
Center of the luminace line width
Center of the luminace line width
Fig. 5-3-13.
VC-214 BOARD
IC202
1
44
132
89
176
133
45
88
IC001
12
1
25 36
13
48
24
37
C085
8. REC L Level Adjustment (VC-214 board)
Set the recording levels of the REC AFM signal and REC ATF signal.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording / playback
image.
If the level is too low, the audio S/N will deteriorated, tracking will
not be stable, or SP/LP will not be discriminated properly. If too
high, color beets will be produced on the self-recording / playback
image.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
(20 MHz BW LIMIT: OFF)
(20 MHz BW LIMIT: OFF)
Adjustment Page
F
Adjustment Address
7B to 84
Specified Value
A=11.0 ± 0.7mV
Note:
Do not insert any plug into the AUDIO (R) terminal.
Connection:
1)
1)
Remove C085 (0.01
µ
F, Pin !§ of IC202).
Note:
After completing “REC L Level Adjustment” and “REC C
Current Adjustment”, replace C085 with new parts (1-182-970-
11 CERAMIC CHIP 0.01
Current Adjustment”, replace C085 with new parts (1-182-970-
11 CERAMIC CHIP 0.01
µ
F 10% 25V).
Preparations only for the model without REC switch:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
remote commander of 8mm VCR.)
Adjusting method:
1)
1)
Insert Hi8 ME tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 7B, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
4)
Select page: F, address: 85, set data: 00, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
5)
Select page: F, address: 7C, change the data and set the REC
AFM signal level (A) to the specified value.
AFM signal level (A) to the specified value.
6)
Press the PAUSE button of the adjustment remote commander.
7)
Select page: F, address: 7C, read the data (D
7C
).
8)
Convert D
7C
to decimal notation, and obtain D
7C
'. (Refer to Table
5-4-1. “Hexadecimal-decimal conversion table” of “5-4. Service
Mode”.)
Mode”.)
9)
Calculate the adjustment data (decimal) from the following
equations (decimal calculation), convert it to a hexadecimal
number, and input each adjustment address.
equations (decimal calculation), convert it to a hexadecimal
number, and input each adjustment address.
Address: 7B
D
7B
' = D
7C
'
Address: 7D
D
7D
' = D
7C
'
Address: 7E
D
7E
' = D
7C
'
Address: 7F
D
7F
' = D
7C
' –68
Address: 80
D
80
' = D
7C
' –68
Address: 81
D
81
' = D
7C
' –68
Address: 82
D
82
' = D
7C
' –68
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
the adjustment remote commander.
10) Write the following data (hexadecimal) in page: F, address: 83
to 84.
Note:
After setting each data, be sure to press the PAUSE button of
the adjustment remote commander.
the adjustment remote commander.
11) Select page: 0, address: 01, and set data: 00.
12) Perform “REC C Current Adjustment”.
12) Perform “REC C Current Adjustment”.
Address
83
84
Data
96
96
Processing after completed adjustment only for the model
without REC switch:
1)
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
5-40
A
1.35
µ
sec
Center of the luminance line width
Fig. 5-3-14.
9. REC C Current Adjustment (VC-214 board)
Set the recording current levels of the REC Chroma signal. If it is
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noises will increase and white modulation noises
will be produced.
too low, chroma signal noise in played back picture will increased.
If too high, Y signal noises will increase and white modulation noises
will be produced.
Mode
VTR recording (SP mode)
Signal
No signal
Measurement Point
Pin 0 of CN910 (REC RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
85
Specified Value
A=35.7 ± 1.3mV
Connection:
1)
1)
Remove C085 (0.01
µ
F, Pin !§ of IC202).
Note:
After completing “REC L Level Adjustment” and “REC C
Current Adjustment”, replace C085 with new parts (1-162-970-
11 CERAMIC CHIP 0.01
Current Adjustment”, replace C085 with new parts (1-162-970-
11 CERAMIC CHIP 0.01
µ
F 10% 25V).
2)
Connect Pin $∞ of IC001 and GND with a 0.01F capacitor.
0.01
0.01
µ
F capacitor: 1-101-004-00
Preparations only for the model without REC switch:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
remote commander of 8mm VCR.)
Adjusting method:
1)
1)
Insert a tape, and set to recording mode.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 2, address: 01, set data: 41, and press the PAUSE
button of the adjustment remote commander.
button of the adjustment remote commander.
4)
Select page: 6, address: 61, and set data: 30.
5)
Select page: F, address: DE, after note down the data, set data:
00, and press the PAUSE button of the adjustment remote
commander.
00, and press the PAUSE button of the adjustment remote
commander.
6)
Select page: F, address: 85, change the data and set the REC
chroma signal level (A) to the specified value.
chroma signal level (A) to the specified value.
7)
Press the PAUSE button of the adjustment remote commander.
8)
Select page: F, address: DE, set the data noted down at step 5),
and press the PAUSE button of the adjustment remote
commander.
and press the PAUSE button of the adjustment remote
commander.
9)
Select page: 6, address: 61, and set data: 10.
10) Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
11) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
Click on the first or last page to see other CCD-TR913E / CCD-TR950E service manuals if exist.