5-41
3-5. IR TRANSMITTER ADJUSTMENTS
Adjust using a IR receiver jig (J-6082-383-A).
Note :
If the distance between the IR receiver jig and the camcorder is
below 1m, cover the LASER LINK emitter with a ND filter. (For
example, when the distance is 30cm to 50cm, cover the LASER
LINK emitter with a ND filter 1.0.)
Switch setting:
LASER LINK ........................................ ON (Red LED is lit)
1. IR Video Carrier Frequency Adjustment (VC-214 board)
Mode
Camera standby
Subject
Arbitrary
Measurement Point
Pin 5 of CN003 of IR receiver jig (RF)
(Or Pin !§ of IC751 of VC-214 board)
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
68
Specified Value
f = 11.85 ± 0.05 MHz
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Fig. 5-3-15.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 37, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 68, change the data, and set the video
carrier frequency (f) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
2. IR Video Deviation Adjustment (VC-214 board)
Mode
Camera standby
Subject
Arbitrary
Measurement Point
VIDEO OUT terminal of IR receiver jig
(Terminated at 75
)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
66
Specified Value
A = 0.87 ± 0.04 V
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Fig. 5-3-16.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 39, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 66, and change the data, set the video
signal amplitude (A) to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
Main unit
IR receiver jig
Pin 
5
 of 
CN003
Frequency counter
Main unit
IR receiver jig
VIDEO
OUT
75
75
 (1-247-804-11)
Oscilloscope
A
H
Fig. 5-3-17.
5-42
(75
)
600
Video
L
R
Audio
AUDIO OUT
L
47k
47k
 (1-249-437-11)
600
 
(270
 (1-249-410-11) + 330
 
(1-249-411-11))
Pattern generator
Audio oscillator
Main unit
Attenuator
Audio level meter
VIDEO OUT
R
IR receiver jig
Fig. 5-3-18.
3. IR Audio Deviation Adjustment (VC-214 board)
Mode
VTR recording
Signal
Audio signal :
400Hz, –7.5dBs : L or R of AUDIO
terminal
Video signal :
Color bar signal : VIDEO terminal
Measurement Point
AUDIO L terminal and AUDIO R
terminal of IR receiver jig
(Terminated at 47k
)
Measuring Instrument
Audio level meter
Adjustment Page
F
Adjustment Address
67
Specified Value
Signal level: –7.5 ± 2.0 dBs
Level difference of L and R: Below 2dB
Connection of Equipment
Connect the measuring device as shown in the following figure,
and adjust.
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
4)
Insert a tape, and set to recording mode. (Use the wireless
remote commander of 8mm VCR.)
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Connect the audio level meter to the AUDIO L terminal of the
IR receiver jig.
3)
Select page: F, address: 67, change the data and set the 400Hz
audio signal level to the specified value.
4)
Press the PAUSE button of the adjustment remote commander.
5)
Connect the audio level meter to the AUDIO R terminal of the
IR receiver jig.
6)
Check that the 400Hz audio signal level is within the specified
value. If outside, repeat from step 2).
7)
Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.
5-43
3-6. AUDIO SYSTEM ADJUSTMENT
• Perform the adjustment using color bar signal as a video signal
input for the VIDEO terminal.
• The items to be adjusted for the R channel will be indicated within
the [ ], in regard to the adjusting items to be adjusted for both L
and R channels.
• Set the Hi-Fi sound switch in the menu display to “STEREO”
position unless specified otherwise.
Note :
1) When inputting the audio signal, input same signal to both the L and R
channels, unless otherwise.
2) Be sure insert the plug (Shorting plug or dummy plug, etc) into the
AUDIO terminal (Right). If the plug is not inserted, the monaural mode
will be set, and correct adjustments can not be carried out.
[Monaural mode]
During recording ............... REC AFM RF 1.7MHz carrier will not be
output.
During playback ................ The L + R signal will be output from the
AUDIO terminal (Left).
 [Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to the
video system measuring instruments as shown in Fig. 5-3-19, and
perform adjustments at the power switch [PLAYER] position.
[Adjustment Procedure]
1)
1.5MHz deviation adjustment
2)
1.7MHz deviation adjustment
3)
BPF f
adjustment
Pattern generator
Video output
(75 
)
Audio
oscillator
Attenuator
600 
600 
 (270 
 (1-249-410-11) +330 
 (1-249-411-11))
Main unit
Main unit
VIDEO
VIDEO
AUDIO
AUDIO
L
R
L
R
L
R
In Recording
In Playback
47k 
47k 
 :1-249-437-11
47k 
 :1-249-437-11
Audio level meter or
distortion meter
TV monitor
When connecting AFM DEV jig.
Oscilloscope
TP27
(GND)
TP28(DC)
CH1
B
INV
A
SIN
8 0 !¡
AFM DEV jig 
(J-6082-312-A)
TP33(GND)
TP32(R OUT 1) 
B
 
TP31(L OUT 1) 
A
TP29(L OUT 2)
TP30(R OUT 2)
S2
S1
S3
PAL
NT
ST
BIL
J1(R)
J2(L)
J3
TP2(R OUT)
B
TP3(L OUT)
A
TP1(GND)
TP26
TP24
TP25
CN2
CH2
CN1
Use the CPC-7 jig
(J-6082-382-A)
Red
Red
White
CN910
VC-214 board
GND
REC RF
RF SWP
A
 :1.5MHz deviation adjustment.
B
 :1.7MHz deviation adjustment.
To Audio terminal
White
+
Stabilized power supply
  (+7Vdc to +9Vdc)
Fig. 5-3-19.
5-44
A
Approx. 2msec
Fig. 5-3-20.
1. 1.5 MHz Deviation Adjustment (VC-214 board)
Sets the spectrum of the L-ch ((L+R)/2 signal) level modulated
during recording. If deviated, the crosstalk signal of the audio signal
will occur and the audio level will drop during both playback and
recording.
Mode
VTR recording
Signal
Input the AFM DEV jig output signal to
the left and right audio input terminal
Measurement Point
CH1: AFM DEV jig TP31
CH2: AFM DEV jig TP3
Measuring Instrument
Oscilloscope
ADD mode
CH2 INV mode
Adjustment Page
F
Adjustment Address
62
Specified Value
The level difference between CH1 signal
and CH2 signal should be minimum.
Connection:
1)
Connect TP24 ,TP25 and TP26 of the AFM DEV jig to CN910
of the VC-214 board.
TP24(GND) ................ Pin 8 of CN910
TP25(REC RF) ........... Pin 0 of CN910
TP26(RF SWP) .......... Pin !¡ of CN910
2)
Connect the audio output terminal (J1 and J2) of the AFM DEV
jig to AUDIO terminal of the unit.
3)
Connect TP28(DC), TP27(GND) of the AFM DEV jig to the
DC power supply (+7Vdc to +9Vdc).
4)
Set the AFM DEV jig switches to the following positions.
S1 ........................... BIL Position
S2 ........................... PAL Position
S3 ........................... SIN Position
Preparations only for the model without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “4-3, 3. Bit value
discrimination” of “5-4. Service Mode”).
3)
Select page: D, address: 15, after memorizing the data, set the
bit value of bit7 to “0”.
4)
Set to recording mode. (Use the wireless remote commander
of 8mm VCR.)
Adjusting method :
1)
Match the vertical ranges of CH1 and CH2 of the oscilloscope
to each other.
2)
Set the oscilloscope to the ADD mode and CH2 to the INV
(invert) mode.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: F, address: 62, change the data and minimize the
audio signal level difference (A).
5)
Press the PAUSE button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment only for the model
without REC switch:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3)
Press the PAUSE button of the adjustment remote commander.
4)
Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5)
Press the PAUSE button.
6)
Select page: 0, address: 01, and set data: 00.