Sony CCD-TR913E / CCD-TR950E Service Manual ▷ View online

5-17
8. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note)
Adjustment Page
F
Adjustment Address
49
Specified Value
C0 to FF
Note:
The right two digits of the DDS display data is the object data.
00 00 XX
Object data
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT ................................................................ OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3)
Select of page: 0, address: 03, and set data: 01.
4)
Select page: 6, address: 56, and set data: 40.
5)
Select page: 6, address: 01, set data: 19, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: F, address: 49, set data: 08, and press the PAUSE
button.
7)
Check that the DDS display data (Note) lies within the specified
value.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 56, and set data: 00.
9. Auto White Balance Standard Data Input
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
32 to 35
Note 1:
This adjustment should be carried out upon completion of “6. Color
Reproduction Adjustment”.
Note 2:
Check that the data of page: 6, address: 02 is “00”. If not, select
page: 6, address: 01, set data: 00, and press the PAUSE button of
the adjustment remote commander.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT ................................................................ OFF
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Wait for 2 seconds.
3)
Select page: 6, address: 01, set data: 11, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 01, set data: 0D, and press the PAUSE
button.
(When the standard data is take in, the data will be automatically
input to page: F, address: 32 to 35.)
5)
Select page: 6, address: 02, and check that the data is “01”.
6)
Perform “Auto White Balance Adjustment”.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
5-18
10. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
DDS display of LCD or TV monitor
Measuring Instrument
(Note 2)
Adjustment Page
F
Adjustment Address
54, 55
Specified Value
R ratio: 2C40 to 2CC0
B ratio: 5E40 to 5EC0
Note 1:
Perform “Auto White Balance Standard Data Input” before this
adjustment.
Note 2:
The right four digits of the DDS display data is the object data.
00 XXXX
Object data
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT ................................................................ OFF
Adjusting method:
1)
Place the C14 filter for color temperature correction on the
lens.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 01, set data: 3F, and press the PAUSE
button.
5)
Select page: 0, address: 03, and set data: 04.
6)
Select page: F, address: 54, change the data, and adjust the
average value of the DDS display data (Note 2) to the R ratio
specified value.
7)
Press the PAUSE button.
8)
Select page: 0, address: 03, and set data: 05.
9)
Select page: F, address: 55, change the data, and adjust the
average value of the DDS display data (Note 2) to the B ratio
specified value.
10) Press the PAUSE button.
Processing after Completing Adjustments
1)
Select page: D, address: 11, set data: 00, and press the PAUSE
button of the adjustment remote commander.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5-19
R-Y
2mm
B-Y
2mm
R-Y
B-Y
1.0mm
1.0mm
3mm
3mm
R-Y
B-Y
3mm
3mm
2.0mm
1.0mm
Fig. 5-1-10. (A)
Fig. 5-1-10. (B)
Fig. 5-1-10. (C)
11. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-10. A to C
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT ................................................................ OFF
Checking method:
1)
Check that the lens is not covered with either filter.
2)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
3)
Check that the center of the white luminance point is within
the circle shown Fig. 5-1-10. (A).
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 01, set data: 23, and press the PAUSE
button.
6)
Place the C14 filter on the lens.
7)
Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-10. (B).
8)
Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3)
on the lens.
9)
Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
10) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-10. (C).
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5-20
12. Angular Velocity Sensor Sensitivity Preset and
Steady Shot Check
Check the output of the angular velocity sensor.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03JA
Type B
ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
5F, 60
Specified Value
PITCH data : 3000 to 4600
YAW data  : 3000 to 4600
Note:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
ZOOM .......................................................................... Center
2)
STEADY SHOT (Menu display) ...................................... ON
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 5F, set data: 76, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 60, set data: 63, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 03, and set data: 11.
5)
Select page: 1, and check that the PITCH data satisfies the
specified value.
6)
Select page: 0, address: 03, and set data: 12.
7)
Select page: 1, and check that the YAW data satisfies the
specified value.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Select page: 0, address: 03, and set data: 00.
3)
Check that the steady shot operations have been performed
normally.
Page of 127
Display

Click on the first or last page to see other CCD-TR913E / CCD-TR950E service manuals if exist.