DOWNLOAD Sony CCD-TR913E / CCD-TR950E Service Manual ↓ Size: 33.08 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TR913E CCD-TR950E
Pages
127
Size
33.08 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-tr913e-ccd-tr950e.pdf
Date

Sony CCD-TR913E / CCD-TR950E Service Manual ▷ View online

5-5
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ellow
Cyan
Green
White
Magenta
Red
Blue
Y
ellow
Cyan
Green
White
Magenta
Red
Blue
White
Black
841mm
1189mm
Color bar chart (Color reproduction adjustment frame)
Fig. a
(VIDEO IN/OUT terminal
output waveform)
Fig. b (monitor TV picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the monitor TV display shown in Fig. b.
Fig. 5-1-4.
Fig. 5-1-5.
1-1-4. Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform
adjustments without loading cassette.
1.
POWER switch (MA-353 board) ........................... CAMERA
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
VIDEO LIGHT switch (MA-353 board) ......................... OFF
4.
DEMO MODE (Menu display) ....................................... OFF
5.
DIGITAL ZOOM (Menu display) ................................... OFF
6.
STEADY SHOT (Menu display) ..................................... OFF
7.
FOCUS switch (MR-8500 block) ......................... MANUAL
8.
PROGRAM AE (CF-58 board) ....................................... Auto
9.
BACK LIGHT (CF-58 board) .......................................... OFF
10. PICTURE EFFECT (CF-58 board) ................................. OFF
11. DIGITAL EFFECT (CF-58 board) .................................. OFF
12. 16 : 9 WIDE (MENU display) ......................................... OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 5-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 5-1-5. using A0 size (1189mm 
×
841mm) black and white vellum paper.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
5-6
Address
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
Initial value
00
88
8D
A8
BD
C8
Remark
Test mode
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Battery end adj.
Fixed data-1
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
1-2. INITIALIZATION OF D, E, F PAGE DATA
1. Initializing the D,E,F Page Data
Note:
If the D,E,F page data has been initialized, “Modification of D, E, F
Page Data” and all adjustments need to be performed again.
Adjusting Page
D
Adjusting Address
00 to 6F
Adjusting Page
F
Adjusting Address
00 to FF
Adjusting Page
E
Adjusting Address
00 to FF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 00, and set data: 51.
3)
Select page: 6, address: 01, set data: 51, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 6, address: 02, and check that the data is 01.
5)
Select page: 2, address: 00, and set data: 29.
6)
Select page: 2, address: 01, set data: 29, and press the PAUSE
button of the adjustment remote commander.
7)
Perform “Modification of D,E,F Page Data”.
2. Modification of D, E, F Page Data
If the D, E, F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: 
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
5)
After completing “Modification of D, E, F Page Data”, select
page: 0, address: 01, and set data: 00. Also perform all
adjustments.
3. D Page Table
Note :
Fixed data-1 : Initialized data. (Refer to “1. Initializing the D,E,F
Page Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of D, E, F
Page Data”.)
5-7
Address
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
Initial value
Remark
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Table. 5-1-2.
Address
00 to 0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
Initial value
00
00
00
00
00
00
00
00
00
00
00
00
47
80
A0
80
2B
80
65
80
1C
03
25
24
11
05
0A
00
8C
Remark
Emergency memory address
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
AGC gain calibration adj.
AWB standard data input
Fixed data-1
(Initialized data)
Flange back adj.
Switching position adj.
28MHz origin osc. adj.
Fixed data-1
(Initialized data)
4. F Page table
Note :
Fixed data-1 : Initialized data. (Refer to “1. Initializing the D,E,F
Page Data”.)
Fixed data-2 : Modified data. (Refer to “2. Modification of D, E, F
Page Data”.)
5-8
Address
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
Initial value
84
68
08
33
34
8D
87
41
49
2A
00
19
00
37
76
63
83
7A
8D
7A
41
33
C7
6B
40
9A
7B
60
70
70
70
70
63
6B
63
6B
Remark
Fixed data-1
(Initialized data)
HALL adj.
Max gain adj.
Fixed data-1
(Initialized data)
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
(Initialized data)
Auto white balance adj.
IRIS IN/OUT adj.
Fixed data-1
(Initialized data)
Flange back adj.
Angular velocity sensor sensitivity
preset and steady shot check.
CAP FG offset adj.
1.5MHz deviation adj.
1.7MHz deviation adj.
BPF f
0
 adj.
Fixed data-1
IR video deviation adj.
IR audio deviation adj.
IR video carrier freq. adj.
Y OUT level adj.
AFC f
0
 adj.
C OUT level adj.
Fixed data-1
Filter f
0
 adj.
RP filter f
0
 adj.
Fixed data-1
(Initialized data)
REC Y current adj.
Address
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
Initial value
C0
C0
C0
C0
7C
7C
7C
7C
96
96
80
Remark
REC L level adj.
REC C current adj.
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Page of 127
Display

Click on the first or last page to see other CCD-TR913E / CCD-TR950E service manuals if exist.