5-21
12. Angular Velocity Sensor Sensitivity Adjustment
(CCD-TR640E/TR730E/TR840E/TR845E)
• This adjustment is performed only when replacing the angular
velocity sensor.
Although this adjustment need not be performed when the circuit
is damaged, etc., check the operations.
• Note down the sensitivity displayed on the angular velocity sensor
of the repair parts. At this time, note down also to which board it
was attached to.
Be sure to check because if attached incorrectly, the screen will
vibrate up and down or left and right during hand-shake correction
operations.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03EA or ENC 03JA
Type B : ENC03EB or ENC 03JB
Replace the broken sensor with a same type sensor. If replace with
other parts, the image will vibrate up and down or left and right
during hand-shake correction operations. After replacing, re-adjust
according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Adjustment page
F
Adjustment Address
43, 44
Note:
The sensor sensitivity of SE451 and SE452 of  the SE-65
board is written only on the repair parts.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Read the sensor sensitivity written on SE451 of the SE-65 board,
and take this as S
451
.
3) Read the sensor sensitivity written on SE452 of the SE-65 board,
and take this as S
452
.
4) Calculate D
43
' and D
44
' using the following equation (decimal
calculation).
D
43
' = 118 / S
451
D
44
' = 106 / S
452
5) Convert D
43
' and D
44
' into hexadecimal digits, to obtain D
43
 and
D
44
. (Round off decimal points)
6) Select page: F, address: 43, set data: D
43
, and press the PAUSE
button of the adjusting remote commander.
7) Select page: F, address: 44, set data: D
44
, and press the PAUSE
button of the adjusting remote commander.
Processing after Completing Adjustments
1) Select page: 0, address: 01, and set data: 00.
2) Check that the steady shot operations have been performed
normally.
5-22
1-4. COLOR ELECTRONIC VIEWFINDER SYSTEM
ADJUSTMENT
(CCD-TR512E/TR730E)
Note 1:
The back light (fluorescent tube) is driven by a high voltage
AC power supply. Therefore, do not touch the back light
holder to avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent
damages caused by static electricity.
[Adjusting connector]
Most of the measuring points for adjusting the viewfinder system
are concentrated in CN910 of the VC-195 board.
Connect the measuring instruments via the CPC-7 jig (J-6082-382-
A).
The following table shows the Pin No. and signal name of CN910.
1. EVF Initial Data Input
Pin No. Signal Name
Pin No. Signal Name
1
LANC SIG
9
RF AGC OUT
2
XCPC IN
10
REC RF
3
IR VIDEO
11
RF SWP
4
AFC F0
12
CAP FG
5
BPF MONI
13
EVF BL
6
PB RF
14
EVF BL 4.75V
7
RF AGC IN
15
VCO
8
REG GND
16
EVF VG
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: E, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjusting remote commander each
time to set the data.
3) Select page: 0, address: 01, and set data: 00.
Fig.5-1-11.
Mode
VTR stop
Signal
No signal
Adjustment Page
E
Adjusting Address
C2 to CD
Address
Data
Remark
C2
B0
VCO adjustment
C3
80
Bright adjustment
C4
77
Contrast adjustment
C5
80
White balance adjustment
C6
80
White balance adjustment
C7
68
Fixed value
C8
50
Fixed value
C9
F8
Fixed value
CA
A8
Fixed value
CB
3C
Fixed value
CC
B0
Backlight Consumption
Current Adjustment
CD
70
Fixed value
Screw driver (–)
Cover
5-23
2. VCO Adjustment (VF-119 board)
Set the VCO free-run frequency. If deviated, the EVF screen will be
blurred.
Mode
VTR stop
Signal
No signal
Measurement point
Pin 
!
  of CN910 (VCO) on VC-195
board
Measuring instrument
Oscilloscope (DC range)
Adjustment page
E
Adjustment address
C2
Specified value
A = 1.8 
±
 0.1Vdc
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjusting remote commander.
3) Check the GND level of the oscilloscope.
5) Select page: E, address: C2, change the data and set the VCO
output voltage (A) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
3. Bright Adjustment (VF-119 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement point
Pin 
!§ of CN910 (EVF VG) on VC-195
board
Measuring instrument
Oscilloscope
Adjustment page
E
Adjustment address
C3
Specified value
A = 7.2 
±
 0.1 V
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjusting remote commander.
3) Select page: E, address: C3, change the data and set the voltage
(A) between the reversed waveform pedestal and non-reversed
waveform pedestal to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Fig. 5-1-12.
Fig. 5-1-13.
H
A
GND level
(0 Vdc)
A
2H
5-24
4. Contrast Adjustment (VF-119 board)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjusting remote commander.
3) Select page: E, address: C4, change the data and set the voltage
(A) between the 7 step peak and the pedestal to the specified
value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 
!§  of CN910 (EVF VG) on
VC-195 board
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
C4
Specified Value
A = 2.0 
±
 0.1V
Fig. 5-1-14.
5. Backlight Consumption Current Adjustment (VF-120
board)
Set the backlight luminance and color temperature.
If deviated, the image may become dark or bright.
Mode
VTR stop
Signal
No signal
Measurement Point
+ Probe: Pin 
!¢  of CN910
(EVF BL 4.75V) on VC-195 board
– Probe: Pin 
!£ of CN910 (EVF BL)
on VC-195 board
Measuring Instrument
Digital voltmeter
Adjustment Page
E
Adjustment Address
CC
Specified Value
A = 21.0 
±
 1.0 mVdc
Note:
Adjust 30 seconds after running on the power supply.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 55, and press the PAUSE
button of the adjusting remote commander.
3) Select page: E, address: CC, change the data and set the voltage
difference (A) between Pin 
!¢ of CN910 (EVF BL 4.75V) and
Pin 
!£ of CN910 (EVF BL) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
6. White Balance Adjustment (VF-119 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
E
Adjustment Address
C5, C6
Specified Value
The EVF screen should not be colored.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 51, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 2, address: 7D, and set data: 03.
4) Select page: E, address: C5 and C6, set the data to the initial
value.
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjusting remote commander each
time to set the data.
Address
C5
C6
Data
80
80
5) Check that the LCD screen is not colored. If colored, change the
data of page: E, address: C5 and C6 so that the EVF screen is
not colored.
Note:
To write in the non-volatile memory (EEPROM), press
the PAUSE button of the adjusting remote commander each
time to set the data.
6) Select page: 2, address: 7D, and set data: 00.
7) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
8) Select page: 0, address: 01, and set data: 00.
A
2H
7 step peak
Page of 127