DOWNLOAD Sony CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E Service Manual ↓ Size: 19.31 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TR311 CCD-TR311E CCD-TR411E CCD-TR412E CCD-TR511E CCD-TR512E CCD-TR640E CCD-TR730E CCD-TR840E CCD-TR845E
Pages
127
Size
19.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M CCD-TR311/311E/411E''98 AEP
File
ccd-tr311-ccd-tr311e-ccd-tr411e-ccd-tr412e-ccd-tr5.pdf
Date

Sony CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E Service Manual ▷ View online

5-1
Parts Code
J-6080-058-A
J-6080-808-A
J-6080-818-A
J-6082-200-A
J-6020-250-A
J-6082-053-B
J-6080-875-A
J-6082-382-A
J-6082-223-A
J-6082-312-A
J-6080-621-A
J-6082-357-A
J-6082-188-A
Name
Filter for color temperature correction
(C14)
ND filter 1.0
ND filter 0.3
Pattern box PTB-450
Color chart for pattern box
Adjusting remote commander
(RM-95-remodeled partly)  Note 1
Siemens star
CPC-7 jig
Power code  Note 2
AFM DEV jig
Clear chart
Extension cable (16P, 0.5 mm)
Extension cable (48P, 0.8 mm)
Ref. No.
J-1
J-2
J-3
J-4
J-5
J-6
J-7
J-8
J-9
J-10
J-11
J-12
Note 1:
If the micro processor IC in the adjusting remote
commander is not the new micro processor (UPD7503G-
C56-12), the pages cannot be switched. In this case, replace
with the new micro processor (8-759-148-35).
SECTION 5
ADJUSTMENTS
Refer to page 3 as Table for distinction
functions of models and classification
5-1.
CAMERA SECTION ADJUSTMENTS
1-1. PREPARATIONS BEFORE ADJUSTMENT
(CAMERA SECTION)
1-1-1. List of Service Tools
• Oscilloscope
• Adjusting driver
Usage
Auto white balance adjustment/check
White balance adjustment/check
White balance check
White balance check
For checking the flange back
For the color viewfinder adjustment
For adjusting the video section
For connecting the battery terminal and DC power supply
For adjusting the deviation
For extension between the CD-181 board (CN401) and
VC-195 board (CN501)
For extension between the DD-105 board (CN931) and
VC-195 board (CN914)
• Color monitor
• Regulated power supply
• Vectorscope
• Digital voltmeter
Note 2:
Connect the adjusting remote commander to the LANC
jack, and set the HOLD switch to the “ADJ” side, or press
the battery switch of the battery terminal using adhesive
tape, etc.
Fig. 5-1-1.
J-1
J-2
J-3
J-4
J-5
J-7
J-6
J-8
J-9
J-10
J-11
J-12
CCD-TR311/TR311E/TR411E/TR412E/TR511E/TR512E/
TR640E/TR730E/TR840E/TR845E
5-2
1-1-2. Preparations
Note 1:
For details of how remove the cabinet and boards, refer to
“2. DISASSEMBLY”.
Note 2:
When performing only the adjustments, the lens block and
boards need not be disassembled.
1) Connect the equipment for adjustments according to Fig. 5-1-3,
4.
2) By setting the “Forced Camera Power ON mode”, the camera
power can be turned ON even if the front panel block (MA-311
board, power switch, microphone unit) has been removed. When
removing the front panel block disconnect the following
connector.
1. VC-195 board CN903 (23P 0.5mm)
3) The intelligent accessory shoe (Intelligent accessory shoe model)
need not be assembled. If removing it. disconnect the following
connector.
1. VC-195 board CN909 (10P, 0.5mm)
Note 3:
As removing the cabinet (R) (removing the VC-195 board
CN911) means removing the lithium 3V power supply
(CF-49 board) , data such as date, time, user-set menus
will be lost. After completing adjustments, reset these data.
If the cabinet (R) has been removed, the self-diagnosis
data, data on history of use (total drum rotation time etc. )
will be lost. Before removing, note down the self-diagnosis
data and data on the history use. (Refer to the “Service
Mode” of  “VIDEO SECTION ADJUSTMENT” for the
data on the history use.)
Note 4:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the
PAUSE button of the adjusting remote commander.
The above procedure will enable the camera power to
be turned on with the front panel block removed. After
completing adjustments, be sure to exit the “Forced
Camera Power ON Mode”.
Note 5:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the
PAUSE button of the adjusting remote commander.
3) Select page: 0, address: 01, and set data: 00.
Fig. 5-1-2.
Pattern box
Front of lens
1.5m
5-3
Fig. 5-1-3.
Note 1:
Connect the adjusting remote commander to the LANC
jack, and set the HOLD switch to the “ADJ” side, or press
the battery switch of the battery terminal using adhesive
tape, etc. or use the AC power adaptor.
   
Color monitor
Vector scope
Terminated at 75
 Ω
Lens block
CD-181 board
CN401
Extension cable(16P)
(J-6082-357-A)
Need not connected
VIDEO terminal
CN909
CN551
CN902
CN903
CN901
CN001
CN905
CN906 CN908
CN914
CN910
CN911
CN912
Battery switch
MA-311 board
CN303
Extension cable(48P)
(J-6082-188-A)
CPC-7 jig
(J-6082-382-A)
Must be connected when
performing the VIDEO system
or color EVF system
adjustments.
CN935
CN932
CN934
CN801
CN931
DD-105
board
LANC
terminal
Adjusting
remote
commander
Regulaterd power supply
(8.4 
±
 0.1 Vdc)
Battery
terminal
VC-195
board
CN501
(Note 1)
CF-49 board CN001
5-4
1-1-3.Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform
adjustments without loading cassette.
1. POWER switch (MA-311 board) ........................... CAMERA
2. NIGHT SHOT switch (Lens Block) ................................ OFF
(Night shot model)
3. DEMO MODE (Menu display) ....................................... OFF
4. DIGITAL ZOOM (Menu display) ................................... OFF
5. STEADY SHOT (Menu display) .................................... OFF
6. FOCUS switch (MF-8500) .................................... MANUAL
(Manual Focus model)
7. PROGRAM AE (CF-49 board) ....................................... Auto
8. BACK LIGHT (CF-49 board) ......................................... OFF
9. PICTURE EFECT (CF-49 board) ................................... OFF
10. 16 : 9 WIDE (MENU display) ........................................ OFF
2. Adjusting Procedure
Adjust in the given order.
Fig. 5-1-4.
3. Subject
1) Color bar chart (Standard picture frame)
Adjust the picture frame as shown in Fig. 5-1-4. if adjustments
are performed using the color bar chart.
(Standard picture frame)
2) White pattern (Standard picture frame)
Remove the color bar chart from the pattern box, and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3) Chart for flange back adjustment
Combine a white A0 size (1189 mm x 841 mm) paper to a black
one, and make the chart shown in Fig. 5-1-5.
Fig. 5-1-5.
Note :
Use the non-reflecting and non-glazing vellum paper
whose size is more than A0, and make the boundary
between white and black to be smoothly flat.
Color bar chart standard picture trame
H
A
B
A=B
B
A
±
 0.1 msec
V
Enlargement
Difference in level
A
B
Electronic beam
scanning frame
CRT picture frame
Fig. b. (TV monitor picture)
Yellow
Cyan
Green
White
Magenta
Red
Blue
Yellow
Cyan
Green
White
Magenta
Red
Blue
Fig. a. (Video output terminal
            output wavefom)
Adjust the camera zoom and direction to obtain the output wavefom
shown in Fig. a and the TV monitor display shown in Fig. b.
841 mm
1189 mm
White
Black
Page of 127
Display

Click on the first or last page to see other CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E service manuals if exist.