DOWNLOAD Sony CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E Service Manual ↓ Size: 19.31 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TR311 CCD-TR311E CCD-TR411E CCD-TR412E CCD-TR511E CCD-TR512E CCD-TR640E CCD-TR730E CCD-TR840E CCD-TR845E
Pages
127
Size
19.31 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / S/M CCD-TR311/311E/411E''98 AEP
File
ccd-tr311-ccd-tr311e-ccd-tr411e-ccd-tr412e-ccd-tr5.pdf
Date

Sony CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E Service Manual ▷ View online

5-49
3-5.
STEREO AUDIO SYSTEM ADJUSTMENT
(CCD-TR730E/TR840E/TR845E)
Perform the adjustment using the color bar signal as a video
signal input for VIDEO terminal.
The items to be adjusted for the R channel will be indicated
within the [ ], in regard to the adjusting items to be adjusted for
both L and R channels.
Set the Hi-Fi sound switch in the menu display to “STEREO”
position unless specified otherwise.
Note:
1) When inputting the audio signal, input the same signal to both
the L and R channels, unless specified otherwise.
2) Be sure to insert the plug (Shorting plug or dummy plug, etc)
into the AUDIO terminal (Right). If the plug is not inserted, the
monaural mode well be set, and correct adjustments can not be
carried out.
[Monaural mode]
During recording ............... REC AFM RF 1.7MHz carriear will
not be output.
During playback ................ The L+R signal will be output from
the AUDIO terminal (Left).
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to the
video system measuring instruments as shown in Fig. 5-3-17, and
perform adjustments at the power switch [VTR] or [PLAYER]
position.
[Adjustment Procedure]
1) 1.5 MHz deviation adjustment
2) 1.7 MHz deviation adjustment
3) BPF adjustment
Fig. 5-3-17.
TP33(GND)
TP32(R OUT 1) 
B
TP31(L OUT 1) 
A
 
TP30(R OUT 2)
TP29(L OUT 2)
CN1
J3
J1(R)
J2(L)
S2
PAL         NT
INV        SIN
S3
S1
ST
BIL
CH1
CH2
TP27
(GND)
TP28 (DC)
+
-
(+7Vdc to +9Vdc)
(J-6082-312-A)
AFM DEV jig
TP2(R OUT)
B
TP1(GND)
TP3(L OUT)
A
A
: 1.5MHz deviation adjustment.
B
: 1.7MHz deviation adjustment.
When connecting AFM DEV jig.
CN1
TP25
TP24
TP26
B
A
Stabilized power supply
Oscilloscope
Red
White
White
Red
L
R
To Audio terminal
VC-195 board
IC301 
 PIN
(REC AFM)
0.01 
µ
F
(1-101-004-00)
CN910 
 PIN
(RF SWP)
CN910 
8
 PIN
(GND)
Use the CPC-7 jig
(J-6082-382-A)
Pattern generator
In Recording
In Playback
Audio
oscillator
Video output
(75 
)
Attenuator
600 
600 
 (270 
 (1-249-410-11) + 330 
 (1-249-411-11))
VIDEO
Main unit
L
R
AUDIO
Audio level meter or
distortion meter
47k
47k
 : 1-249-437-11
VIDEO
Main unit
L
R
AUDIO
TV monitor
47k
 : 1-249-437-11
CN2
5-50
1. 1.5 MHz Deviation Adjustment (VC-195 board)
Sets the spectrum of the L-ch ((L+R)/2 signal) level modulated
during recording. If deviated, the crosstalk signal of the audio signal
will occur and the audio level will drop during both playback and
recording.
Mode
VTR recording
Signal
Input the AFM DEV jig output signal to
the left and right audio input terminal
Measurement Point
CH1: AFM DEV jig TP31
CH2: AFM DEV jig TP3
Measuring Instrument
Oscilloscope
ADD mode
CH2 INV mode
Adjustment Page
F
Adjustment Address
45
Specified Value
The level difference between CH1 signal
and CH2 signal should be minimum.
Connection:
1) Connect TP24 and TP26 of the AFM DEV jig to CN910 of the
VC-195 board.
TP24(GND) ...................... Pin 
8 of CN910
TP26(RF SWP) ................. Pin 
!¡ of CN910
2) Connect TP25 (REC AFM) of the AFM DEV jig to Pin 
@ª of
IC301 with a 0.01
µ
F capacitor (1-101-004-00).
3) Connect the audio output terminal (J1 and J2) of the AFM DEV
jig to AUDIO terminal of the unit.
4) Connect TP28 (DC), TP27 (GND) of the AFM DEV jig to the
DC power supply (+7Vdc to +9Vdc).
5) Set the AFM DEV jig switches to the following positions.
S1 ............................... BIL Position
S2 ............................... PAL Position
S3 ............................... SIN Position
Preparations only for the model without REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “3. Bit value discrimination”
of “3-1-8. Service Mode”).
3) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to “0”.
4) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin 
6 of CN935 of DD-105 board
and GND with 4.7k
 resistor for a second.)
4.7k
 resistor : 1-249-425-11
Fig. 5-3-18.
Approx. 2msec
A
Adjusting method :
1) Match the vertical ranges of CH1 and CH2 of the oscilloscope
to each other.
2) Set the oscilloscope to the ADD mode and CH2 to the INV
(invert) mode.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: F, address: 45, change the data and minimize the
audio signal level difference (A).
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment: only for the model without
REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
5-51
2. 1.7 MHz Deviation Adjustment (VC-195 board)
Sets the spectrum of the R-ch ((L-R)/2 signal) level modulated during
recording. If deviated, the crosstalk signal of the audio signal will
occur and the audio level will drop during both playback and
recording.
Mode
VTR recording
Signal
Input the AFM DEV jig output signal to
the left and right audio input terminal
Measurement Point
CH1: AFM DEV jig TP32
CH2: AFM DEV jig TP2
Measuring Instrument
Oscilloscope
ADD mode
CH2 normal mode
Adjustment Page
F
Adjustment Address
46
Specified Value
The level difference between CH1 signal
and CH2 signal should be minimum.
Connection:
1) Connect TP24 and TP26 of the AFM DEV jig to CN910 of the
VC-195 board.
TP24 (GND) ..................... Pin 
8 of CN910
TP26 (RF SWP) ................ Pin 
!¡ of CN910
2) Connect TP25 (REC AFM) of the AFM DEV jig to Pin 
@ª of
IC301 with a 0.01
µ
F capacitor (1-101-004-00).
3) Connect the audio output terminal (J1 and J2) of the AFM DEV
jig to AUDIO terminal of the unit.
4) Connect TP28 (DC), TP27 (GND) of the AFM DEV jig to the
DC power supply (+7Vdc to +9Vdc).
5) Set the AFM DEV jig switches to the following positions.
S1 ............................... BIL Position
S2 ............................... PAL Position
S3 ............................... INV Position
Preparations only for the model without REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, after memorizing the data, set the
bit value of bit1 to “1”. (Refer to “3. Bit value discrimination”
of “3-1-8. Service Mode”).
3) Select page: D, address: 15, after memorizing the data , set the
bit value of bit7 to “0”.
4) Set to recording mode. (Use the wireless remote commander
of 8mm VCR, or connect Pin 
6 of CN935 of DD-105 board
and GND with 4.7k
 resistor for a second.)
4.7k
 resistor : 1-249-425-11
Fig. 5-3-19.
Approx. 2msec
A
Adjusting method :
1) Match the vertical ranges of CH1 and CH2 of the oscilloscope
to each other.
2) Set the oscilloscope to the ADD mode and CH2 to the normal
mode.
3) Select page: 0, address: 01, and set data: 01.
4) Select page: F, address: 46, change the data and minimize the
audio signal level difference (A).
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
Processing after completed adjustment: only for the model without
REC switch:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 14, and set the data memorized at step
2) of “Preparations only for the model without REC switch”.
3) Press the PAUSE button of the adjusting remote commander.
4) Select page: D, address: 15, and set the data memorized at step
3) of “Preparations only for the model without REC switch”.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
5-52
3. BPF f0 Adjustment (VC-195 board)
Sets the BPF passing frequency so that the AFM signal can separate
from the playback RF signal properly. If deviated. the mono/stereo
mode will be differentiated incorrectly, and noises and distortions
will increase during high volume playback.
Mode
Playback
Signal
Alignment tape:
For BPF adjustment
(WR5-11CS)
Measurement Point
Audio output terminal left or right
Measuring Instrument
distortion meter
Adjustment Page
F
Adjustment Address
47
Specified Value
The Main and Sub channel distortion
rate should be almost the same
(within
±
1%) and minimum.
Adjusting method :
1) Select page: 0, address: 01, and set data: 01.
2) Set the Hi-Fi sound switch (menu display) to “2”.
3) Select page: F, address: 47, change the data and minimize the
distortion rate.
4) Press the PAUSE button of the adjusting remote commander.
5) Set the Hi-Fi sound switch (menu display) to “1”.
6) Select page: F, address: 47, change the data and minimize the
distortion rate.
7) Press the PAUSE button of the adjusting remote commander.
8) Repeat steps 2) to 7) and set the data of address: 47 so that the
distortions rates when the Hi-Fi sound switch is set to “2” and
set to “1” respectively are almost the same and minimum.
9) Press the PAUSE button of the adjusting remote commander.
11) Select page: 0, address: 01, and set data: 00.
12) Set the Hi-Fi sound switch to “STEREO”.
3-6.
MONAURAL AUDIO SYSTEM ADJUSTMENT
MONAURAL
(CCD-TR311/TR311E/TR411E/TR412E/TR511E/
TR512E/TR640E)
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments besides the video
system measuring instruments as shown Fig. 5-3-20.
Fig. 5-3-20.
Audio
generator
Attenuator
600 
Parts cord 600 
 :
270 (1-249-410-11) + 330 (1-249-411-11)
AUDIO
terminal
Audio level meter
or distortion meter
47k
Parts cord 47k
 : 1-249-437-11
AUDIO
terminal
• Connection of Audio generator and attenuator.
• Connection of Audio level meter or distortion meter
Page of 127
Display

Sony CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E Service Manual ▷ Download