5-37
5. Switch check (2)
Page 3
Address 60 to 65
Using method:
1) Select page: 3, address: 60 to 65.
2) By discriminating the display data, the pressed key can be
discriminated.
6. Headphone jack check
Page 3
Address 45
Bit
Function
When bit value=1 When bit value=0
1
Headphone jack
Headphone jack is
used
Using method:
1) Select page: 3, address: 45.
2) By discriminating the bit value of display data, the state of the
headphone jack can be discriminated.
Page 3
Address 49
Bit
Function
When bit value=1 When bit value=0
1
2
3
4
MIC jack
MIC jack is used
5
AUDIO terminal
Monaural
Stereo
6
VIDEO terminal
VIDEO terminal is
used
7
S VIDEO terminal
S VIDEO terminal
is used
Using method:
1) Select page: 3, address: 49.
2) By discriminating the bit value of display data, the state of the
input/output selection can be discriminated.
7. Input/output selection check
No key input
No key input
NORMAL REC
(CF-49 S024)
PROGRAM AE
AUTO
(CF-49 S020)
FOCUS
MANUAL
(MF-8500
 S001)
No key input
PUSHING REC
(CF-49 S024)
PROGRAM AE
LOW LIGHT
(CF-49 S020)
FOCUS AUTO
(MF-8500
 S001)
EDIT SEARCH
(–)
(FK8500 S010)
5sec REC
(CF-49 S024)
PROGRAM AE
LANDSCAPE
(CF-49 S020)
FOCUS
INFINITY
(MF-8500
 S001)
EDIT SEARCH
(+)
(FK8500 S009)
TIME
(CF-49 S021)
PROGRAM AE
SUNSET &
MOON
(CF-49 S020)
FADER
(MF-8500 S002)
REC
(FK-8500
 S005, 007)
PLAY
(FK-8500 S006)
EXECUTE
(CF-49 S015)
PROGRAM AE
BEACH & SKI
(CF-49 S020)
BACK LIGHT
(CF-49 S017)
TITLE
(CF-49 S018)
FF
(FK-8500 S003)
REW
(FK-8500 S004)
MENU
(CF-49 S010)
PROGRAM AE
SPORTS
LESSON
(CF-49 S020)
EXPOSURE
(CF-49 S012)
STOP
(FK-8500 S001)
PAUSE
(FK-8500 S002)
PICTURE
EFFECT
(CF-49 S006)
PROGRAM AE
PORTRAIT
(CF-49 S020)
COUNTER
RESET
(CF-49 S008)
PHOTO REC
(SS-8500 S004)
DIGITAL
EFFECT
(CF-49 S001)
PROGRAM AE
SPOT LIGHT
(CF-49 S020)
DATE
(CF-49 S003)
Data
Address
00 to 0D
0E to 29
2A to 46
47 to 68
69 to 90
91 to BE
BF to EA
EB to FF
60
(AD0:
IC604 
(£)
61
(AD1:
IC604 
(¢)
62
(AD2:
IC604 
(
)
63
(AD3:
IC604 
(§)
64
(AD4:
IC604 
(¶)
65
(AD5:
IC604 
(•)
5-38
Page 3
Address 05
Bit5
8. LED, LCD (display window) check
Using method:
1) Select page: 3, address: 05, and set the bit value of Bit5 to “1”.
2) Check that all LED are lit and all segments of LCD (display
window) are lit.
3) Select page: 3, address: 05, and set the bit value of Bit5 to “0”.
Page 3
Address A2 to AA
Address
Function
Remarks
1000th place digit and
100th place digit of
counted time
(decimal digit)
10th place digit and 1st
place digit of counted
time (decimal digit)
After setting the clock, set
the date of power on next
A2
A3
A4
A5
A6
A7
A8
A9
AA
Drum rotation
counted time
(BCD code)
User initial power
on date
(BCD code)
Final condensation
occurrence date
(BCD code)
Hour (H)
Hour (L)
Minute
Year
Month
Day
Year
Month
Day
9. Record of Use Check
Using method:
1) The record of use data is displayed at page 3, addresses: A2 to
AA.
Note:
This data will be erased when the coin lithium battery is
removed (reset).
5-39
3-2.
SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of D, E, F Page Data
If the D, E, F page data is erased due to some reason, perform “1-2.
INITIALIZATION OF D, E, F PAGE DATA”, of “5-1. CAMERA
SECTION ADJUSTMENT”.
2. Battery End Adjustment (VC-195 board)
Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten.
The image at the battery end will also be rough.
Mode
Camera recording
Subject
Arbitrary
Measurement Point
LCD display of the adjusting remote
Measuring Instrument
commander
Adjustment Page
D
Adjustment Address
30 to 34
Note 1:
The lens block and cabinet (R) must be connected.
Switch setting
1) AUTO FOCUS ............................. OFF
2) NIGHT SHOT .............................. OFF
(NIGHT SHOT model)
Connection:
1) Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-4.
Adjusting method:
1) Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.1
±
0.1Vdc.
2) Turn off the power supply.
3) Turn on the HOLD switch of the adjusting remote commander.
4) Turn on the power supply.
5) Load a cassette, and set to the camera recording mode.
6) Select page: 0, address: 01, and set data: 01.
7) Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.30
±
0.01Vdc.
8) Select page: 3, address: 5D, read the data, and this data is named
Dref.
9) Select page: D, address: 30, set data: Dref, and then press the
PAUSE button of the adjusting remote commander.
10) Convert Dref to decimal notation, and obtain Dref '. (Refer to
Table 5-1-2. “Hexadecimal-decimal conversion table”)
11) Calculate D
31
', D
32
', D
33
' and D
34
' using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 31
D
31
' = Dref ' + 5
Address: 32
D
32
' = Dref ' + 32
Address: 33
D
33
' = Dref ' + 53
Address: 34
D
34
' = Dref ' + 64
Note 3:
 After setting each data, be sure to press the PAUSE button.
12) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-4.
5-40
3-3.
SERVO SYSTEM ADJUSTMENTS
1. CAP FG Offset Adjustment (VC-195 board)
Improve the capstan servo characteristic. If it is not correct. jitters
will increase.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
Pin 
!™ of CN910 (CAP FG)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
69
Specified value
Duty = 50
±
1%
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 01, and set data: 81, and press the PAUSE
button of the adjustment remote commander. (to start up
automatic CAP FG offset adjustment.)
3) Select page: 2, address: 02, and check that the data is “01”.
4) Check that Duty of CAP FG signal satisfies the specified value.
If not, select page: 2, address: 01, set data: 00, and press the
PAUSE button, and then, repeat steps 2) to 4).
5) Select page: 2, address: 01, and set data: 00, and press the PAUSE
button of the adjustment remote commander.
6) Select page: 0, address: 01, and set data: 00.
2. Switching Position Adjustment (VC-195 Board)
If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Playback
Signal
Alignment tape:
For tracking adjustment
(WR5-1NP (NTSC))
(WR5-1CP (PAL))
Measurement Point
CH1: Pin 
!¡ of CN910 (RF SWP)
CH2: Pin 
6 of CN910 (PB RF)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
7C, 7D
Specified Value
t1 = 0
±
10
µ
sec
Note 1:
NTSC MODEL: CCD-TR311
PAL MODEL:
CCD-TR311E/TR411E/TR412E/
TR511E/TR512E/TR640E/TR730E/
TR840E/TR845E
Adjusting Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 2A, and set data: 20, and press the PAUSE
button of the adjustment remote commander.
3) Select page: F, address: 7C, change the data and minimize “t1”,
and then press the PAUSE button of the adjustment remote
commander. (Coarse adjustment)
4) Select page: F, address: 7D, change the data and adjust so that
the switching position (t1) becomes the specified value. (Fine
adjustment)
5) Press the PAUSE button of the adjustment remote commander.
6) Select page: F, address: 2A, and set data: 00, and press the PAUSE
button of the adjustment remote commander.
7) Select page: 0, address: 01, and set data: 00.
Fig. 5-3-5.
Fig. 5-3-6.
Page of 127
Display

Click on the first or last page to see other CCD-TR311 / CCD-TR311E / CCD-TR411E / CCD-TR412E / CCD-TR511E / CCD-TR512E / CCD-TR640E / CCD-TR730E / CCD-TR840E / CCD-TR845E service manuals if exist.