2. Projective Resolving Power Checking Method
1) Turn the focus ring of the checking lens until the chart image projected on the screen is the sharpest at the center (y = 0).
2) Read the number of the smallest pitched lines at the center (y = 0).
1) Turn the focus ring of the checking lens until the chart image projected on the screen is the sharpest at the center (y = 0).
2) Read the number of the smallest pitched lines at the center (y = 0).
The number represents for lines per mm.
Sagittal (S)
Meridional (M)
Fig.
4-4-3
3) Rotate the mount rotational plate of the lens projector while observing y = 9, y = 12, y = 15 or y = 18 and stop it at the location where
the projective resolving power is the worst (low).
Read the number of the smallest pitched lines (both sagittal and meridional: 3 lines) at the peripheral point.
Note:
Note:
When reading the number of the smallest pitched lines, be careful of the spurious resolution.
Spurious resolution is the reversed image of 2 or 4 lines which appears on screen when focus is beyond maximum revolving power as shown in
Fig. 4-4-4.
Fig. 4-4-4.
Do not confuse spurious resolution for the smallest pitched lines.
Correct resolution
Spurious resolution
Fig.
4-4-4
4) Change the focal length and projected length of the checking lens. (In case of the zoom lens), project the S image and the M image at
each focal point/projected length and confirm that the number of resolution satisfies the specification of the Table 4-4-1.
Specification
Focal length
f (mm)
Distance
(m)
Number of the smallest pitched lines/mm
Center (y = 0)
Neighborhood (y = 15)
Neighborhood (y = 18)
S
M
S
M
70
2.8
More than 100 lines
More than 63 lines
More than 63 lines
More than 50 lines
More than 40 lines
200
8.0
More than 50 lines
More than 50 lines
More than 40 lines
More than 40 lines
400
16.0
Table 4-4-1
5) Confirm the projective resolving power. If the value does not satisfy the specification, perform 4-4-2. Projective Resolving Power
(Partial Blur) Adjustment.
4-4-2. Projective Resolving Power (Partial Blur) Adjustment
Check the projective resolving power. If the value does not satisfy the specification, perform the projective resolving power adjustment.
1. Adjustment Method 1 (TELE end)
In case that the partial blur exists at the TELE end (f=400 mm)
1) Remove the 1st lens assy.
2) Adjust the partial blur by increasing or decreasing the 1st tilt adjustment washers between the 1st lens assy and the 1st adjustment wash-
2) Adjust the partial blur by increasing or decreasing the 1st tilt adjustment washers between the 1st lens assy and the 1st adjustment wash-
er.
Note:
Note:
Insert the 1st tilt adjustment washer in the position of the back-focus tendency.
(When the 1st tilt adjustment washer is inserted in the position of the back-focus tendency, the inserted position tilts to the front-focus side.)
Install the 1st lens assy to the original position.
When performing the partial blur adjustment, tighten the screws, starting with the location where the 1st tilt adjustment washer is inserted.
3) Confirm the projective resolving power. And if the value does not satisfy the specification, perform repeatedly steps 1) and 2).
1st Lens Assy
1st Tilt Adjustment
Washer
Washer
1st Adjustment
Washer
Washer
Decoration Barrel
Filter Screw Frame
Decoration Barrel
Fig.
4-4-5
1st tilt adjustment washer
Part No.
Thickness t (mm)
3-296-858-01
0.02
3-296-858-11
0.03
3-296-858-21
0.05
3-296-858-31
0.1
Table 4-4-2
4-8
SAL70400G2 (4-5.6/70-400 G SSM Ⅱ) (70-400mm F4-5.6 G SSM Ⅱ)
2. Adjustment Method 2 (WIDE end)
In case that the partial blur exists at the WIDE end (f=70 mm)
1) Remove the rear light shield barrel and the light shield ring.
2) Loosen three screws fixing the 6th assy, adjust the position of the 6th assy by performing the correction by decentering and tighten the
2) Loosen three screws fixing the 6th assy, adjust the position of the 6th assy by performing the correction by decentering and tighten the
screws.
Note:
Note:
By moving the 6th assy from the front-focus tendency position to the back-focus tendency position, the partial blur can be improved.
3) After performing the projective resolving power (partial blur), check the projective resolving power again and confirm that the value
satisfies the specification.
4) If not satisfied, perform repeatedly steps 2) and 3) again.
Three Screws
Light Shield Ring
Rear Light Shield Barrel
Fig.
4-4-6
4-5. FOCUS-SHIFT/FLANGE BACK (f F) CHECK/ADJUSTMENT
In this section, the check and adjustment of focal point, which varies when changing the focal length by zooming, are described.
Equipment
• 1000 mm Collimator
• Flange Back Tester
•
• 1000 mm Collimator
• Flange Back Tester
•
A-mount Attachment
• Flange Back Gauge (43.50 mm)
• Adhesive bond (B-10)
• Adhesive bond (B-10)
4-5-1. Focus-shift/Flange Back (f F) Check
1. Preparation
1) Execute 1. Preparation of 4-3. OPTICAL AXIS CHECK/ADJUSTMENT .
1) Execute 1. Preparation of 4-3. OPTICAL AXIS CHECK/ADJUSTMENT .
2. Focus-Shift Check
1) Set the zoom to the TELE end.
2) Set the flange back tester to 44.56 mm by rotating the knob.
3) Adjust the focus by rotating the focus ring from the NEAR end.
4) By rotating the zoom from TELE to WIDE and from WIDE to TELE, confirm that the value at each focal length satisfies the specifica-
1) Set the zoom to the TELE end.
2) Set the flange back tester to 44.56 mm by rotating the knob.
3) Adjust the focus by rotating the focus ring from the NEAR end.
4) By rotating the zoom from TELE to WIDE and from WIDE to TELE, confirm that the value at each focal length satisfies the specifica-
tion.
Note:
Note:
Do not rotate the focus ring.
Specification
Focal length f (mm)
400
300
200
135
100
70
Flange back value f F (mm)
(Reference value: 44.56 mm)
(Reference value: 44.56 mm)
+0.2
+0.3
+0.2
-0.2
-0.15
(44.36 to 44.76)
(44.36 to 44.86)
(44.41 to 44.76)
Table 4-5-1
5) In case that the flange back value (f F) of checking lens does not satisfy the specification in Table 4-5-1, perform 4-5-2. Focus-shift/
Flange back (f F) Adjustment .
3. Flange Back (f F) Check
1) Set the zoom to the TELE end and the focus to the over infinity end respectively and confirm that the value satisfies the specification.
2) Set the zoom to the WIDE end and the focus to the over infinity end respectively and confirm that the value satisfies the specification.
1) Set the zoom to the TELE end and the focus to the over infinity end respectively and confirm that the value satisfies the specification.
2) Set the zoom to the WIDE end and the focus to the over infinity end respectively and confirm that the value satisfies the specification.
Specification (Over infinity end)
Focal length f (mm)
TELE end (400 mm)
WIDE end (70 mm)
Flange back value f F (mm)
48.135
±
0.09 (48.045 to 48.225)
44.68
±
0.09 (44.59 to 44.77)
Table 4-5-2
3) In case that the flange back value (f F) of checking lens does not satisfy the specification in Table 4-5-2, perform 4-5-2. Focus-shift/
Flange back (f F) Adjustment .
4-5-2. Focus-Shift/ Flange Back (f F) Adjustment
1. Preparation
1) Perform 4-5-1. Focus-shift/Flange back (f F) Check and confirm that the flange back (f F) at each focal length does not satisfy the
1) Perform 4-5-1. Focus-shift/Flange back (f F) Check and confirm that the flange back (f F) at each focal length does not satisfy the
specification in Table 4-5-1.
2. Adjustment Method 1 (TELE end)
1) Set the zoom to the TELE end (400 mm) and the focus to the over infinity end.
2) Adjust the focus by rotating the knob of flange back tester and read the value of flange back. (Read value: a)
3) Calculate the amount of 1st adjustment washer to be increased or decreased by entering the result a read in step 2) in the formula be-
1) Set the zoom to the TELE end (400 mm) and the focus to the over infinity end.
2) Adjust the focus by rotating the knob of flange back tester and read the value of flange back. (Read value: a)
3) Calculate the amount of 1st adjustment washer to be increased or decreased by entering the result a read in step 2) in the formula be-
low. (The amount of 1st adjustment washer to be increased or decreased: X)
X (Amount of 1st adjustment washer to be increased or decreased) =
(a (Focal length 400 mm , f F (read value) at the over infinity end - 48.135) / 4.5
• In case that the value X (amount of 1st adjustment washer) is negative (-), decrease the thickness of 1st adjustment washer.
• In case that the value X (amount of 1st adjustment washer) is positive (+), increase the thickness of 1st adjustment washer.
• In case that the value X (amount of 1st adjustment washer) is positive (+), increase the thickness of 1st adjustment washer.
Specification (mm): 48.045 to 48.225
4) According to the result obtained from step 3), increase or decrease the 1st adjustment washer.
1st Lens Assy
1st Tilt Adjustment
Washer
Washer
1st Adjustment
Washer
Washer
Decoration Barrel
Filter Screw Frame
Decoration Barrel
Fig.
4-5-1
1st adjustment washer
Part No.
Thickness (mm)
4-124-714-01
0.02
4-124-714-11
0.03
4-124-714-31
0.1
4-124-714-41
0.2
Table 4-5-3
5) Adjust by repeating steps 1) to 4) until the specification is satisfied.
4-9
SAL70400G2 (4-5.6/70-400 G SSM Ⅱ) (70-400mm F4-5.6 G SSM Ⅱ)
3. Adjustment Method 2 (WIDE end)
Note:
• After finishing the adjustment method 1 (TELE end), perform this adjustment.
• In case of performing the adjustment method 2 (WIDE end), be sure to perform the adjustment method 1 (TELE end).
1) Set the zoom to the WIDE end (70 mm) and the focus to the over infinity end.
2) Adjust the focus by rotating the knob of flange back tester and read the value of flange back. (Read value: b)
3) Calculate the amount of back adjustment washer to be increased or decreased by entering the result b read in step 2) in the formula
2) Adjust the focus by rotating the knob of flange back tester and read the value of flange back. (Read value: b)
3) Calculate the amount of back adjustment washer to be increased or decreased by entering the result b read in step 2) in the formula
below. (The amount of back adjustment washer to be increased or decreased: Y)
Y (Amount of back adjustment washer to be increased or decreased) =
(b (Focal length 70 mm , f F (read value) at the over infinity end)) - 44.68
• In case that the value Y (amount of back adjustment washer) is negative (-), decrease the thickness of back adjustment washer.
• In case that the value Y (amount of back adjustment washer) is positive (+), increase the thickness of back adjustment washer.
• In case that the value Y (amount of back adjustment washer) is positive (+), increase the thickness of back adjustment washer.
Specification (mm): 44.59 to 44.77
4) According to the value obtained from step 3), increase or decrease the back adjustment washer.
Back Adjustment
Washer
Washer
Signal Board
Rear Light
Shield Barrel
Shield Barrel
Mount Assy
Fig. 4-5-2
Back Adjustment Washer
Part No.
Thickness (mm)
4-125-256-01
0.02
4-125-256-11
0.03
4-125-256-31
0.1
4-125-256-41
0.2
Table 4-5-4
5) Adjust by repeating steps 1) to 4) until the specification is satisfied.
4. Selection and Installation of Preset Lever
1) Select the preset lever, depending on the amount of back adjustment washer.
1) Select the preset lever, depending on the amount of back adjustment washer.
Preset
Lever
Part No.
Amount of back adjustment washer (mm)
4-124-865-11
0 to 0.3 or less
4-124-865-21
0.3 to 0.6 or less
4-124-865-31
0.6 to 0.9 or less
4-124-865-41
0.9 or more
Table 4-5-5
2) Install the preset lever and fix it with two screws.
3) Perform the aperture diameter check/adjustment. (Refer to section 4-2.)
4) Apply the adhesive bond (B-10) to the indicated portion of preset lever.
3) Perform the aperture diameter check/adjustment. (Refer to section 4-2.)
4) Apply the adhesive bond (B-10) to the indicated portion of preset lever.
Apply the adhesive
bond (B-10)
bond (B-10)
Two Screws
Preset Lever
Fig.
4-5-3
5) Perform the adjustment method 1 (TELE end) again.
6) Measure the flange back value at each focal length and confirm that the value satisfies the specifications in Table 4-5-1.
6) Measure the flange back value at each focal length and confirm that the value satisfies the specifications in Table 4-5-1.
4-6. FOCUSING ERROR AMOUNT CHECK
Shoot images with the checking lens and the AE master lens under the following conditions (Note 1), and compare the images to check the
error amount (Note 2).
Note 1:
error amount (Note 2).
Note 1:
・
Shooting magnification (60, 40, 20 times)
・
Chart for checking the depth area of image-formation (tilting chart 2 types)
・
Defocus value 0
±
10
μ
m
Note 2:
The higher the magnification, the focusing error amount becomes the bigger. Therefore, it is easy to judge of result.
If the error amount is outside of the range, perform 4-11-3.
⊿
SB Check/ Write .
Equipment
• Chart for checking the depth area of image-formation (40, 60 times)
Acquire the Chart_for_checking_image_formation_40x_60x_(E).zip from the each HQ.
• Chart for checking the depth area of image-formation (20 times)
Acquire the Chart_for_checking_image_formation_20x_(E).zip from the each HQ.
• Software
Acquire the following either software from the each HQ.
Software
Camera
DSLR-A700 Defocus checker
DSLR-A700
Defocus Checker 2
SLT-A37/A57/A58/A65/A77/A99
Table 4-6-1
• Camera (One of DSLR-A700, SLT-A37/A57/A58/A65/A77/A99)
• HASP key
• Personal Computer (supporting Seus-EX)
• AE Master Lens
• HASP key
• Personal Computer (supporting Seus-EX)
• AE Master Lens
J-6082-597-A: 50 mm/F1.7
• Illumination
J-6082-642-A: Fluorescent Lamp (specified color rendering)
J-6082-643-A: Fluorescent Light Stand (high-frequency lighting type)
J-6082-643-A: Fluorescent Light Stand (high-frequency lighting type)
• Memory Card
• Tripod
• Tripod
1. Preparation
1) Insert the memory card to the camera.
2) Set the camera and chart for checking the depth area of image-formation as shown in Table 4-6-2, Fig. 4-6-1 and Fig. 4-6-2.
1) Insert the memory card to the camera.
2) Set the camera and chart for checking the depth area of image-formation as shown in Table 4-6-2, Fig. 4-6-1 and Fig. 4-6-2.
Note 1:
Shooting distance is obtained by shooting magnification and focal length as following.
[Shooting distance] = [shooting magnification]
×
[focal length]
Note 2:
Select the combination according to the Table 4-6-2 Guidelines table.
Note 3:
If the shooting distance using a 60 times chart cannot be ensured indoors, temporarily use a combination of 40 times chart or 20 times chart.
4-10
SAL70400G2 (4-5.6/70-400 G SSM Ⅱ) (70-400mm F4-5.6 G SSM Ⅱ)
3) Connect the camera and personal computer (when using HASP Key) with USB cable and activate Defocus Checker 2 or DSLR-A700
Defocus checker.
In case Defocus Checker 2 is used, click [Connect] to set connection mode.
Note:
Note:
If an abnormal phenomenon appears during installation of the teleconverter used, install the user s teleconverter.
Guidelines Table
Selection of
Shooting magni-
fication
Shooting magni-
fication
AF Assist Chart (Size)
Refer to Fig. 4-6-1.
Refer to Fig. 4-6-1.
Applicable Cam-
era (image sensor
type)
era (image sensor
type)
Applicable Lens
Calculation example of shoot-
ing distance
[shooting magnification]
ing distance
[shooting magnification]
×
[focal length] = [shooting dis-
tance]
tance]
60 times
(middle distance)
(middle distance)
AF Assist Chart 60 Times
(200 mm
(200 mm
×
100 mm)
APS-C size type
All
60 times
×
50 mm = 3000 mm
40 times
(middle distance)
(middle distance)
AF Assist Chart 40 Times
(132 mm
(132 mm
×
66 mm)
35 mm full size type
All
40 times
×
50 mm = 2000 mm
20 times
(short distance)
(short distance)
AF Assist Chart 20 Times
(66 mm
(66 mm
×
33 mm)
both size available
• Macro lens
• Lens with a focal
• Lens with a focal
length of more
than 300 mm
than 300 mm
20 times
×
300 mm = 6000 mm
Table
4-6-2
(100 mm)
(66 mm)
(33 mm)
(200 mm)
(132 mm)
(66 mm)
AF Assist Chart
60 Times
60 Times
AF Assist Chart
40 Times
40 Times
AF Assist Chart
20 Times
20 Times
Fig.
4-6-1
Camera Setting
Exposure mode
Focus Mode
Focus Area
Focus Mode
Focus Area
Image Size
Super SteadyShot
Drive Mode
Super SteadyShot
Drive Mode
: A (Open Aperture)
: MF
: Spot Focus Area
(Fixed at the center)
: L
: OFF
: Self-timer
: MF
: Spot Focus Area
(Fixed at the center)
: L
: OFF
: Self-timer
Shooting distance
Set the optical axis to the center
of the AF assist chart.
of the AF assist chart.
AF Assist Chart
(60 Times/40 Times)
(60 Times/40 Times)
Chart for checking the depth area of image-formation
(60 Times/40 Times)
(60 Times/40 Times)
Fig.
4-6-2
2. Shooting procedure
1) Click the [Start] of Defocus Checker 2 or DSLR-A700 Defocus checker to start the measurements.
2) Adjust defocus value to obtain 0
1) Click the [Start] of Defocus Checker 2 or DSLR-A700 Defocus checker to start the measurements.
2) Adjust defocus value to obtain 0
μ
m in the manual focus mode.
The tolerance is 0
±
10
μ
m . (Fig. 4-6-3)
3) Click the [Stop] of Defocus Checker 2 or DSLR-A700 Defocus checker.
4) Shoot an image by self-timer.
5) Perform the steps 1) to 4) by using the AE master lens and the checking lens.
4) Shoot an image by self-timer.
5) Perform the steps 1) to 4) by using the AE master lens and the checking lens.
Note 1:
Shoot images with the AE master lens and the checking lens using the same camera.
Note 2:
Perform entire work within 10 minutes because values become unstable as the camera temperature increases.
If the work continues for 10 minutes or longer, cool down the camera and then restart the work.
Note 3:
Since focusing error amount increases in shooting images at a middle or long distance, comprehensive focusing error amount cannot be
determined correctly only by results with short-distance setting. If the shooting distance using a 60 times chart cannot be ensured indoors, take
either of the following methods.
determined correctly only by results with short-distance setting. If the shooting distance using a 60 times chart cannot be ensured indoors, take
either of the following methods.
Method 1
Use 35 mm full size type camera (SLT-A99) and 40 times chart. (When using the 40 times chart, shooting distance can shorten to 2/3 of 60
times chart.)
times chart.)
Method 2
Check the focusing error amount of short distance using 20 times chart temporarily. After that, shoot the something images outdoors in the
middle distance for using 60 times chart, and then check the focusing amount of middle distance.
middle distance for using 60 times chart, and then check the focusing amount of middle distance.
Defocus Checker 2
(For SLT-A37/A57/A58/A65/A77/A99)
(For SLT-A37/A57/A58/A65/A77/A99)
DSLR-A700 Defocus checker
(For DSLR-A700)
(For DSLR-A700)
In case Good (0
± less than 10 μm), frame
of waveform area displays in green.
In case Good (0
± less than 10 μm), frame
of waveform area and defocus value display
in green.
in green.
Fig.
4-6-3
Click on the first or last page to see other SAL70400G2 service manuals if exist.