4-7
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
3. Confirmation of PC card setting
1)
Select “All programs” - “MeasumentComputing” - “InstaCal” from the startup menu, and start up the software.
Note:
Depending on the Windows setting, the window below may differ.
Fig.4-1-15
2)
When “PC-CARD-DIO48” is detected, the window below appears. Confirm that the PC-CARD-DIO48” is checked.
Note:
Depending on the slot inserted, the slot No. differs.
Fig.4-1-16
3)
Confirm that “PC-CARD-DIO48” is recognized as “Board#0”.
Note:
If not recognized as “Board#0”, the program does not work properly.
Fig.4-1-17
4)
Click “File” - “Exit” to terminate “InstaCal”.
4-8
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
4. Startup of Lens Adjustment Program (ActuatorChecker.exe)
1)
Download the file “ActuatorChecker VerX.X.X.X.zip” from Service Fixture and Software of ESI homepage, save and extract it.
2)
Start up “ActuatorChecker.exe” from an arbitrary folder.
3)
If “PC-CARD-DIO48” is properly installed, the window below appears.
Note:
The version of “ActuatorCheker” might be updated.
Fig.4-1-18
4-9
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
4-1-3. Connection of Finished Inspection JIG and Lens Adjustment Program
(ActuatorChecker.exe)
Note:
Confirm “4-1-2. Lens Adjustment Program (ActuatorChecker)” has been completed before this procedure is executed.
Equipment
• Personal Computer
• USB cord with connector
• Finished Inspection JIG (AC 100 V only)
• Lens Adjustment Program (ActuatorChecker.exe)
1.
Connect equipment and checking lens as shown Fig.4-1-19.
Fig.4-1-19
2.
Turn on the finished inspection JIG.
3.
Turn on the personal computer.
4.
Start up “ActuatorChecker.exe” from an arbitrary folder, conform that start up program normally.
Note:
Turn off the finished inspection jig after use.
Finished Inspection JIG
Lens
4-10
SAL500F80 (REFLEX 8/500) (500mm F8 Reflex)
4-1-4. Initial Setting of “ActuatorChecker”
1.
Start up “ActuatorChecker.exe”.
Fig.4-1-20
2.
Depending on the initial startup or setting made at the previous startup, the window differs.When the English window appears, click
the 
[Set up]
 button.
Note:
When any button is clicked, the Serial window appears. The window to enter the lens serial number appears.
Fig.4-1-21