Section 2
Service Note
2-1. 
Operation Notes
2-1-1. 
Flexible Board
• Make sure that the conductive side of a flexible board does not have any stain or foreign materials.
• Do not touch the conductive side of flexible boards with bare hands.
• Plug in a flexible board straight, fully into the connector until it reaches the end inside.
Flexible
Board
Flexible
Board
Connector
Connector
Reference line
Flexible
Board
Connector
Connector
Flexible
Board
Reference line
Connector
Connector
Flexible
Board
Flexible
Board
Reference line
OK 
(The flexible board was plugged in 
straight and completely)
(The flexible board was plugged in 
crooked.)
NG 
NG 
(The flexible board was not plugged in 
completely.)
• When opening the connector's holder in direction A, do not open it with excessive force.
Holder
Connector
Flexible Board
A
A
• When closing the connector's holder, press it evenly while pushing a flexible board in direction B.
Holder
Insulation side
Connector
Flexible Board
B
• Make sure that the flat cable and flexible board are not cracked or bent at the contact end.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
• Do not apply excessive force to the gilded flexible board.
2-1-2. 
Fine-Wire Coaxial Cable
• The proper way to disconnect a connector is to grab the connector instead of the wires. If you pull on the wires,
they might be broken.
• The proper way to connect a connector is to grab the connector instead of the wires. If you push on the wires, they
might be broken.
DSC-WX500
2-1
2-1-3. 
Discharging of the Flash Capacitor
The charging capacitor for the flash has been charged at high voltage. Therefore, there is a possibility of an electric
shock if you directly handle this capacitor.
The high-voltage charge will not be discharged by simply turning off the unit’s power. Make sure any remaining voltage
is discharged by short-circuiting the flash capacitor with a Short Jig.
Preparing the Short Jig
Make a Short Jig by connecting a small clip to each lead of a resistor with a rated value of approximately 1 kΩ/1 W.
In order to prevent an electric shock, wrap insulating tape completely around the resistor and its leads.
Resistor with a rated value of approximately 
1 k
/1 W (Part No. 1-215-869-11).
Wrap insulating tape completely 
around the resistor and its leads.
Small clip
Small clip
DSC-WX500
2-2
2-2. 
Precaution on Replacing the SY-1056 Board
The board for repair is not recorded the information unique to a model. Therefore the following data are needed to write.
Note
The [LOAD AND WRITE] function in “ADJUSTMENT DATA BACKUP” on the DATA tab in the Adjust Manual
overwrites all data of the unit. Therefore execute the [LOAD AND WRITE] before performing the following operation.
2-2-1. 
Destination Data
The destination data stored in the repairing board is different from the destination setting stored in the board before
replacement in some cases.
When the board has been replaced with a repairing board, be sure to set the destination.
Method of the destination data write:
Start the Adjust Manual in the Adjust Station and execute the “Destination data write” on the ADJUST tab.
2-2-2. 
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have
been written.
These IDs have not been written in a new repairing board. Therefore, after the board has been replaced, be sure to write
these IDs to a new repairing board.
Method of the ID writing:
Start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & USB SERIAL No. INPUT” on
the ADJUST tab.
2-2-3. 
Restore Data
Before replacing the board with a repairing board, be sure to extract the data from the former one.
Method of the data extracting:
Start the Adjust Manual in the Adjust Station and execute the “RESTORE DATA” on the DATA tab.
2-2-4. 
Angular Velocity Sensor
Before replacing the board with a repairing board, be sure to record the sensitivity indicated on the angular velocity
sensor on the repairing board.
The recorded sensitivity indication must be stored in the repairing board.
Method of the angular velocity sensor sensitivity writing:
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj” on the
ADJUST tab.
Note
The sensitivity of the angular velocity sensor is indicated only on the repairing board, but is not indicated on mass
production boards.
DSC-WX500
2-3
2-2-5. 
Update of MAC Address
When a board that contains Wi-Fi has been replaced or when replacing a board that contains the main IC (CPU), the
IC’s unique number (MAC address) must be reloaded.
Procedure of the MAC address update:
Note
Perform the below operations after all work has been done.
1.
Start the Adjust Manual in the Adjust Station and execute the “Wireless LAN Setting (MAC Address)” on
the ADJUST tab.
2.
Operate the unit to initialize of SSID/PW.
Applicable parts:
• SY-1056 Board
Note
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required.
Accordingly, download the Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach
it to the set when returning the set to customer.