5.
Data Save Error
Fig. 6-1-41
Symptom
data cannot be saved normally. (The data set-
ting during adjustment cannot be cancelled)
Cause
Data writing to the flash memory failed.
Connection is faulty.
Power supply is not installed correctly.
Remedy
On the SEUS Operation screen, 
[Set]
 the data
to the pages and addresses displayed in the
message, and 
[Save]
  them. (Cancel manu-
ally the data setting during adjustment.)
Check the connection.
Install the power supply correctly.
1-5-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note 1:
With this data left in the camera, the camera will not
operate normally.
In this case, the 
[Release Data Setting]
  button is displayed in
“red” on the screen as shown in Fig. 6-1-42 and 43. Click the
[Release Data Setting]
 button to cancel the data setting. When
the data setting is cancelled, the button color becomes “white”.
Note 2:
When “Data Save Error” occurred,  the 
[Release Data
Setting]
 button is displayed in “white”.
To cancel the data setting, perform it on the SEUS Op-
eration screen. How to cancel the data setting is displayed
in the error message.
Camera System Adjustment screen
Fig. 6-1-42
LCD System Adjustment screen
Fig. 6-1-43
How to cancel the 
data setting during 
adjustment is 
display here.
6-20
DSC-S600_ADJ
1-6.
INITIALIZATION OF DATA
1.
Initializing All Page Data
By performing the following procedure, data of all pages will be
initialized.
Note:
If all page data have been initialized, all adjustments need
to be performed again.
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0A”.
4) Click 
[All]
  of the ALL SELECT buttons to select all pages.
(Fig. 6-1-44 A)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is “00”.
10) Select page: 80, address: 30, and check that the data is “00”.
11) Perform “Initial Language Data Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
Fig. 6-1-44
2.
Initializing Single Page Data
By performing the following procedure, data of the page that you
want to initialize will be initialized.
Note 1:
If the 6D or 6E or 6F page data have been initialized, the
following adjustment needs to be performed again.
1) Camera system adjustments
Note 2:
If the 8F page data have been initialized, the following
adjustment needs to be performed again.
1) LCD system adjustments
Initializing Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Sector Write]
 on the SEUS screen to display the SEUS
SECTOR WRITE screen.
3) Check that the SET ID is “0A”.
4) Click “All” of the option buttons of target page. (Fig. 6-1-44
B
)
5) Click 
[Write]
 to write the initializing data to the flash memory
of the camera.
6) Wait for 3 sec.
7) Click 
[Close]
 to close the SEUS SECTOR WRITE screen.
8) Click 
[Save]
 on the SEUS screen.
9) Select page: 80, address: 34, and check that the data is “00”.
10) Select page: 80, address: 30, and check that the data is “00”.
11) When 4F page is initialized, perform “Initial Language Data
Check”.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
40
28
01 
[Set]
(Note)
Note:
At this time, the camera is reset and the power is turns off
once and then on again. Accordingly, the SEUS goes in
“disconnect” state, but this is not a trouble. Click 
[Con-
nect]
 on the SEUS screen to restore the “connected” state.
(In case that the power does not turn on again, press the
power button.)
B
A
0A
6-21
DSC-S600_ADJ
6-2. SERVICE MODE
1.
Setting the Test Mode
Page 40
Address A1,  A3
Forced CAMERA mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 01.
Forced MOVIE mode
1) Select page: 40, address: A1, and set data: 01.
3) Select page: 40, address: A3, and set data: 07.
Forced PLAY mode
1) Select page: 40, address: A1, and set data: 01.
2) Select page: 40, address: A3, and set data: 08.
After completing adjustments/repairs, release the data setting.
1) Select page: 40, address: A1, and set data: 00.
2.
Bit Value Discrimination
In the following items, the bit values must be discriminated from
the data displayed on the SEUS. Whether bit values are “1” or “0”
can be discriminated from the table shown below.
Data displayed on SEUS
0 0
bit 3 to bit 0 discriminated
bit 7 to bit 4 discriminated
Bit values
Display on the
bit3
bit2
bit1
bit0
SEUS
or
or
or
or
bit7
bit6
bit5
bit4
0
0
0
0
0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
B
A
Example: If the displayed data is “8E”, bit 7 - bit 4 values can be
discriminated from block (A), and also bit 3 - bit 0 val-
ues from block (B).
6-22
DSC-S600_ADJ
3.
LED Check
Page 80
Address 12
Page 8E
Address FE
Using method:
1) Select page: 00, address: 01, and set data: 01.
2) Select page: 8E, address: FE, and set data: 20.
3) Select page: 80, address: 12, and set data: 01.
4) Check that all LED are lit.
 SELF TIMER/AF ILLUMINATOR
 AE/AF LOCK
 FLASH CHARGE
 MS ACCESS
5) Select page: 80, address: 12, and set data: 00.
6) Select page: 8E, address: FE, and set data: 00.
7) Select page: 00, address: 01, and set data: 00.
8) Click 
[Disconnect]
 on the SEUS screen.
9) Disconnect the USB cable.
10) Turn off the power.
4.
Switch Check (1)
Page 80
Address 13
Using method:
1) Select page: 80, address: 13.
2) By discriminating the read data, the state of the switches can
be discriminated.
Function
When data = 00 When data = 01 When data = 02
Shutter button
(XAE LOCK SW)
OFF
ON
ON
(RL-063 board S201)
Shutter button
(XSHUTTER SW)
OFF
OFF
ON
(RL-063 board S201)
Page of 26