View Sony CDX-4250RV (serv.man3) Service Manual online
CDX-4250RV
CORRECTION-1
Correct your service manual as shown below.
AEP Model
UK Model
SERVICE MANUAL
INCORRECT
CORRECT
• Page 17
!
: indicates corrected portion.
Sony Corporation
Audio Entertainment Group
2000L0441-1D
Printed in Japan
C
2000. 12
Published by General Engineering Dept.
9-926-463-91
SHUF
SHUF
FM RF signal
generator
0.01
µ
F
antenna
terminal
terminal
set
Carrier frequency : 98.00 MHz
Output level
Output level
: 35 dB (56.2 µV)
Mode
: mono
Modulation
: no modulation
Procedure :
1. Set to the test mode. (See page 16.)
2. Push the SOURCE button and set to FM.
1. Set to the test mode. (See page 16.)
2. Push the SOURCE button and set to FM.
Display
FM RDS S-Meter Adjustment
Setting :
D-BASS switch : OFF
SOURCE button : FM
SOURCE button : FM
3. Push the preset 10 button.
4. Adjust RV801 so that the display indication is “16.0”.
4. Adjust RV801 so that the display indication is “16.0”.
Display
Specification : Display indication : 15.8 to 16.2
SHUF
SHUF
FM RF signal
generator
0.01
µ
F
antenna
terminal
terminal
set
Carrier frequency : 98.00 MHz
Output level
Output level
: 35 dB (56.2 µV)
Mode
: mono
Modulation
: no modulation
Procedure :
1. Set to the test mode. (See page 16.)
2. Push the SOURCE button and set to FM.
1. Set to the test mode. (See page 16.)
2. Push the SOURCE button and set to FM.
Display
FM RDS S-Meter Adjustment
Setting :
D-BASS switch : OFF
SOURCE button : FM
SOURCE button : FM
3. Push the preset 10 button.
4. Adjust RV801 so that the display indication is “16.0”.
4. Adjust RV801 so that the display indication is “16.0”.
Display
Specification : Display indication : 10.0 to 10.4
$