DOWNLOAD Sony DSC-S600 (serv.man12) Service Manual ↓ Size: 362.42 KB | Pages: 26 in PDF or view online for FREE

Model
DSC-S600 (serv.man12)
Pages
26
Size
362.42 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS BRAZIL
File
dsc-s600-sm12.pdf
Date

Sony DSC-S600 (serv.man12) Service Manual ▷ View online

6-11
DSC-S600_ADJ
1-3-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program divides the ad-
justment items into five, camera adjustment 1-5. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Button Name
Adjustment
Subject
Adjustment
Adjustment
Page
Address
Siemens star chart with ND filter
6D
B0 to B7, C0 to C7
CAMERA Adjustment 1
Flange Back Adj.
for minipattern box (Note) or
D0 to DB, E1 to F2
Flange back adjustment jig
6F
18 to 53
Siemens star
CAMERA Adjustment 2
Flange Back Check
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
F No. Compensation
6F
60, 6B to 6D
Measure Gain Adj.
Clear chart
6F
6B, 6F
Mechanical Shutter Adj.
(Standard picture frame)
6F
6B to 6D, B8 to BB,
C7, C8
Light Value Adj.
6F
65 to 67
AWB 3200K-5800K
6E
00 to 21, 24 to 49
CAMERA Adjustment 3
Standard Data Input
9 color chart
AWB 3200K-5800K Check
(Standard picture frame)
Color Reproduction
Adj. & Check
6E
60 to 67
CCD Linearity Check
CCD White Defect
Compensation Check
Clear chart
CCD Black Defect
(Standard picture frame)
Compensation Check
6E
72 to 75
CAMERA Adjustment 4
Strobe Adj.
Flash adjustment box (50 cm)
6F
D8 to EF
Flash adjustment box (50 cm)
6D
B8 to BF
CAMERA Adjustment 5
Auto focus illumination Check
6F
10 to 15
Note: 
Dark Siemens star chart.
Table 6-1-2
6-12
DSC-S600_ADJ
1-3-3.
Adjusting Method
1.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation of Flange Back Adj.”.
Fig. 6-1-11
4) If the 
[OK]
 button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-12
Preparation of Flange Back Adj.
(Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note 1:
The attachment lenses are not used.
Note 2:
Take care not to hit the mini-pattern box when ex-
tending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
±
 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-13
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
Note 3:
Take care not to hit the flange back adjustment jig
when extending the lens.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-14
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
6-13
DSC-S600_ADJ
2.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
Fig. 6-1-15
4) Click the 
[OK]
 button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
Fig. 6-1-16
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-17
3.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain Adj.
5. Mechanical Shutter Adj.
6. Light Value Adj.
7. AWB 3200K-5800K Standard Data Input
8. AWB 3200K-5800K Check
9. Color Reproduction Adj. & Check
10. CCD Linearity Check
11. CCD White Defect Compensation Check
12. CCD Black Defect Compensation Check
13. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-19, set
the subject and click the 
[OK]
 button.
Fig. 6-1-18
Check on the LCD screen
Fig. 6-1-19
Transparent window
Effective picture frame
A
A
B
Blue
C14
Magenta
White
Cyan
Red
Yellow
Green
W14
C
C
B
C =
A = B
C14: Filter for AWB 5800K adjustment
A
2
B
3
6-14
DSC-S600_ADJ
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
Fig. 6-1-23
8) Upon successful completion of “9. Color Reproduction Adj.
& Check”, the following message is displayed. Change the
chart in accordance with the message.
Fig. 6-1-24
9) Click the 
[OK]
 button, and the items from “10. CCD Linearity
Check” to “13. Release of Data Setting during Camera Adj.”
will be executed.
10) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-25
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-20
4) Click the 
[OK]
 button, and the items from “3. F No. Compen-
sation” to “6. Light Value Adj.” will be executed.
5) Upon successful completion of “6. Light Value Adj.”, the fol-
lowing message is displayed. Change the chart in accordance
with the message.
Fig. 6-1-21
6) Click the 
[OK]
 button, and the “7. AWB 3200K-5800K Stan-
dard Data Input” and “8. AWB 3200K-5800K Check” will be
executed.
7) After that, “9. Color Reproduction Adj. & Check” will be ex-
ecuted. Upon completion of adjustment, the check result is
displayed on the Color Reproduction Check screen.
Fig. 6-1-22
Page of 26
Display