DOWNLOAD Sony DSC-R1 (serv.man4) Service Manual ↓ Size: 764.7 KB | Pages: 43 in PDF or view online for FREE

Model
DSC-R1 (serv.man4)
Pages
43
Size
764.7 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-r1-sm4.pdf
Date

Sony DSC-R1 (serv.man4) Service Manual ▷ View online

6-7
DSC-R1_ADJ
3.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-7)
Fig. 6-1-6
Fig. 6-1-7
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
woody board A
woody board B
woody board B
woody board C
woody board A
6-8
DSC-R1_ADJ
4.
Preparation of Aging Environment
To detect a high temperature defect exactly, the aging environment in which the temperature is kept to 40
°
C - 45
°
C is required. If there is
not the environment of temperature 40
°
C to 45
°
C, prepare the aging environment by the method given below.
Aging environment preparing example
Fig. 6-1-8
1) Prepare a box (such as cardboard box) of 400 mm width 
×
 300 mm depth 
×
 350 mm height. And attach the height 40 mm foot to the
four corners of box.
2) Make a transparent window with film, etc. to check the camera status during the aging.
3) Make a small hole in the box and insert a thermometer to measure the inside temperature.
Note 1:
Fix the thermometer at the position free from inter ference with the camera.
4) Cover the small pattern box (PTB-1450), which was turned on, with the prepared box, and wait until the temperature reaches 40
°
C to
45
°
C.
Note 2:
To adjust the temperature, move the box. Locating the box in the center of the small pattern box (PTB-
1450) allows the temperature to rise, or shifting it to either side allows the temperature to drop.
Fig. 6-1-9
5) When the temperature reached 40
°
C to 45
°
C, raise the box and place the camera which connects the USB cable and the AC adapter on
the top surface of the small pattern box (PTB-1450), and after turning on the camera, cover with the box again.
Note 3:
As the top surface of the small pattern box (PTB-1450) is hot, place cassette cases under the camera,
avoiding a direct touch of camera to the top surface.
6) Adjusting the temperature to keep it to 40
°
C - 45
°
C, perform the aging for more than 30 minutes.
400 mm
350 mm
300 mm
40 mm
Thermometer
Cardboard box, etc.
Make a transparent window with film, etc.
Camera to be aged
(Connect the USB cable and 
the AC adaptor to the camera)
Place cassette cases under the camera
Attach the height 40mm foot to the four corners
Small pattern box (PTB-1450)
400 mm
Temperature rises when the 
box is located in the center
Temperature drops when the 
box is shifted to either side
6-9
DSC-R1_ADJ
1-1-3.
Using Method of SEUS
The application for adjustment (SEUS) is used to change the coef-
ficient for calculating the signal processing or EVR data. The SEUS
performs two-way communication between PC and set through
the USB terminal. The two-way communication result data can be
written to the nonvolatile memory.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and set with the USB cable.
3) Confirm that the set starts in the USB mode.
4) Start the SEUS on the PC.
5) Click 
[Connect]
 on the SEUS screen. If the connection is nor-
mal, the SEUS screen will be as shown in Fig. 6-1-10, indicat-
ing the
 
“connected”
 
state.
Note:
The SEUS will go in
 
“disconnect” state, if the set is
turned off (for instance, by resetting the set). In such a
case, click 
[Connect]
 on the SEUS screen to restore
the
 
“connected”
 
state.
2.
Operation
Page change
To change the page, click 
[Page]
 on the SEUS screen and enter
the page to be changed. The page is displayed in hexadecimal
notation.
Address change
To change the address, click 
[Address]
 on the SEUS screen and
enter the address to be changed. The address is displayed in
hexadecimal notation.
Data change
To change the data, click 
[Set]
 on the SEUS screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
Data saving
To write the all changed data to the nonvolatile memory, click
[Save]
 on the SEUS screen and wait for more than 3 sec.
Data reading
The data displayed on the SEUS screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click
[Read]
 on the SEUS screen and update the displayed data.
1-1-4.
Precaution on Use of SEUS
Wrong SEUS operation could clear correct adjustment data. To
prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking 
[Page Edit]
 on the SEUS screen be-
fore starting the adjustment.
Saving Method:
1)
Click 
[Page Edit]
 on the SEUS screen to display the SEUS
PAGE EDIT screen.
2)
Click 
[Page]
, and enter the page number to be saved.
3)
Click 
[Read]
 to read the data to be saved from the camera.
4)
Click 
[File]
 and save the data to PC.
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Page Edit]
 on the SEUS screen to display the SEUS
PAGE EDIT screen.
3) Click 
[File]
 and load the data from PC.
4) Click 
[Write]
 on the SEUS PAGE EDIT screen.
5) Click 
[Close]
 to close the SEUS PAGE EDIT screen.
6) Select page: 40, address: 38 and set data: 00.
7) Click 
[Save]
 on the SEUS screen.
8) Select page: 80, address: 34, and check that the data is “00”.
9) Select page: 80, address: 30, and check that the data is “00”.
10) Select page: 00, address: 01 and set data: 00.
Fig. 6-1-10
6-10
DSC-R1_ADJ
1-2.
ADJUSTMENT  PROGRAMS
The DSC-R1 is adjusted with the Automatic Adjustment Program
and the Color Adjustment Program.
The Automatic Adjustment Program automatically controls the
adjustment operations that were formerly entered manually on the
operation screen of the SEUS (some adjustments may be manu-
ally operated on the SEUS operation screen).
The Color Adjustment Program automatically performs “Color
Shading Adj. & Check” “AWB Adj. & Check” and “Liner Matrix
Adj.” of Camera System Adjustment.
1-2-1.
Automatic Adjustment Program
1.
Precautions When Using Automatic Adjustment
Program
1) The Automatic Adjustment Program writes the adjustment re-
sults such as EVR data to the set through two-way communi-
cation with the camera via the SEUS. Accordingly, the Auto-
matic Adjustment Program must be used in the environment
where the SEUS operates.
2) The program run time may vary depending on the environ-
ment of the personal computer used.
3) The SEUS must be already started on the PC when using the
Automatic Adjustment Program. With the SEUS not started,
some adjustment items will take time in adjustment.
2.
Start of Automatic Adjustment Program
Double-click the application file (DSC-R1 Auto-Adj Ver_1.
[]
r
[][]
.exe),
and the Automatic Adjustment Program will start.
Note:
[]
 (numeric value) of the file name varies depending on the
version of Automatic Adjustment Program.
3.
Function of Each Button on Main Menu Screen
When the Automatic Adjustment Program started, the Main Menu
screen in Fig. 6-1-11 will appear. On this screen, select each ad-
justment section.
Fig. 6-1-11
1
[Connecting the Equipment]
 button
A connection diagram of the equipment is displayed.
2
[VIDEO SYSTEM ADJUSTMENT]
 button
The “VIDEO SYSTEM ADJUSTMENT” screen appears.
3
[CAMERA SYSTEM ADJUSTMENT]
 button
The “CAMERA SYSTEM ADJUSTMENT” screen appears.
4
[LCD SYSTEM ADJUSTMENT]
 button
The “LCD SYSTEM ADJUSTMENT” screen appears.
5
[EVF SYSTEM ADJUSTMENT]
 button
The “EVF SYSTEM ADJUSTMENT” screen appears.
6
[END]
 button
The Automatic Adjustment Program finishes.
7
This part indicates the version of Automatic Adjustment Pro-
gram.
6
3
2
1
4
5
7
Page of 43
Display