DOWNLOAD Sony DSC-R1 (serv.man4) Service Manual ↓ Size: 764.7 KB | Pages: 43 in PDF or view online for FREE

Model
DSC-R1 (serv.man4)
Pages
43
Size
764.7 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-r1-sm4.pdf
Date

Sony DSC-R1 (serv.man4) Service Manual ▷ View online

6-15
DSC-R1_ADJ
1-4-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-3. The Automatic Adjustment Program divides the ad-
justment items into eight, camera adjustment 1-8. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note 1:
Use the Color Adjustment Program (R1ColorAdjustment.exe).
Note 2:
Dark Siemens star chart.
Table 6-1-3
Button Name
Adjustment
Subject
Adjustment
Page
Adjustment
Address
6D
1C, 1D, 20, 24,
26 to 39, 3E,
40 to 53, 56, 57
6F
1C, 1D, 20, 24,
26 to 39, 3E,
40 to 67, 6C to 6F,
71 to 79
CAMERA Adjustment 2
Flange Back Check
Siemens star
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
-
-
CAMERA Adjustment 3
Differencial Gain Adj.
Clear chart
(Zoom lens at Wide end)
6B
00 to 45, F0
(Note 1)
Color Shading Adj. & Check
Clear chart
(Zoom lens at Wide end)
6F
06, 07
F No. Compensation
6B
5A to 5E, F0 to F2
6B
64, F0
78
0C to 0F, C0 to CA
Mechanical Shutter Adj.
6B
80 to 8B, 98 to 9D,
F0 to F2
Light Value Adj.
6B
61, 62
C MOS Low Temp. Dark Def.
-
-
C MOS Low Temp. FD Def.
-
-
C MOS HL (Green) Def.
-
-
C MOS HL (Red) Def.
-
-
C MOS HL (Blue) Def.
-
-
C MOS HL (Dark) Def.
-
-
C MOS OF Def.
-
-
Three Continuos Def. Check
-
-
AWB Adj. & Check
6E
00 to 21, 24 to 49
Liner Matrix Adj.
6E
80 to 9F
CAMERA Adjustment 6
C MOS Linearity Check
Clear chart
(Zoom lens at Tele end)
-
-
6B
C0, C2 to DD,
F3 to F5
6E
72 to 75
6D
B8 to BF
6F
10 to 15
CAMERA Adjustment 1
Flange Back Adj.
Siemens star chart with ND filter
for minipattern box (Note 2) or
Flange back adjustment jig
Measure Gain Adj.
CAMERA Adjustment 4
Clear chart
(Zoom lens at Wide end)
CAMERA Adjustment 5
Clear chart
C MOS High Temp. Dark & FD Def.
-
-
Three Continuos Def. Check
-
-
C MOS Blinking Def.
-
-
CAMERA Adjustment 8
Arbitrary
(Zoom lens at Tele end)
(Below 1cm from front the lens)
Strobe Adj.
9 color chart
(Standard picture frame)
(Note 1)
CAMERA Adjustment 7
Auto Focus Illumination Check
Flash adjustment box (50 cm)
6-16
DSC-R1_ADJ
1-4-3.
Adjusting Method
1.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
Preparation of Flange Back Adj.
(Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note:
The attachment lenses are not used.
2) Set the zoom to the TELE end, and install the minipattern box
so that the distance between it and the front of lens of camera
is less than 1 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
±
 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Fig. 6-1-19
Minipattern box
Below 1 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
1) Set the zoom to the TELE end, install the flange back adjust-
ment jig so that the distance between it and the front of lens of
camera is less than 1 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-20
Flange back adjustment jig
Below 1 cm
Camera
6-17
DSC-R1_ADJ
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 1.
2) The automatic adjustment program executes “1. Data Setting
during Camera Adj.”.
3) When “1. Data Setting during Camera Adj.” completed suc-
cessfully, the following screen will appear during execution
of “2. Flange Back Adjustment”. Set the zoom to the WIDE
end, and check the setting of the subject.
(For the subject setting, see “Preparation for Flange Back Ad-
justment”.)
Fig. 6-1-21
4) Click the [OK]  button to execute the adjustment. Upon suc-
cessful completion of adjustment, the following screen will
appear.
Set the zoom to the TELE end, and check the setting of the
subject.
Fig. 6-1-22
5) Click the [OK]  button to execute the adjustment. Upon suc-
cessful completion of adjustment, the following screen will
appear. Following the instruction on the screen, operate the
camera zoom to adjust the zoom position data to the specified
value.
Note:
 Turn the zoom from the WIDE toward the TELE (in
crease the data) to adjust the zoom position data.
If exceeding the data range, return the zoom toward
the WIDE (decrease the data), and then readjust.
Fig. 6-1-23
With the zoom at the WIDE end, 
the data becomes minimum value.
With the zoom at the TELE end, 
the data becomes maximum value.
6) When the zoom position data becomes the specified value, the
screen will change as shown below. Check the setting of the
subject, and then click the [OK] button on the screen.
Fig. 6-1-24
7) Repeat step 5) and 6) seven times, and “2. Flange Back Adj.”
completes. Then, execute “3. Release of Data Setting during
Camera Adj.”.
8) Upon successful completion of all items in Camera Adjust-
ment 1, the following message will be displayed. Click the
[OK] button, and then return the zoom to the WIDE end and
turn off the power switch of the camera. To perform the next
adjustment, wait for more than 5 seconds before turning on
the power switch.
Fig. 6-1-25
If the data fulfills the specified value, 
the 
[OK]
 button is displayed.
Adjust the zoom position data 
to the value displayed here.
6-18
DSC-R1_ADJ
2.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
Fig. 6-1-26
4) Click the 
[OK]
 button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
Fig. 6-1-27
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-28
Page of 43
Display

Click on the first or last page to see other DSC-R1 (serv.man4) service manuals if exist.