4-15
3 Group Assy
Lever
Lever
1 Frame Assy
Cabinet Number
Flexible Board
Claws
Main Body
Claws
Cam Tube A
Rotary Cam Tube
Semicircular 
Cutout
Gear Edge
Rotary Tube
Stationary Tube Assy
8. Install the Rotary Cam Tube to the Rotary Tube aligning the semicircular cutout with the Gear edge.
9. Install the Stationary Tube Assy at the position shown in the figure as a guideline.
    Note: Be sure to install the Rotary Cam Tube with the semicircular cutout and the Gear edge set in the "OK" state shown in the figure.
10. Install the Main Body so that the Flexible Board position matches the hole to pass the Flexible Board.
5. Install the 1 Frame Assy so the Lever positions match.
    Note: Confirm that the Barrier closes when the 1 Frame Assy is pushed.
6. Set the 3 Group Assy in the groove in the orientation where the Flexible Board comes to the nearly opposite side of the cabinet number 
    on the Cam Tube A.
    Note: Be sure to set the 3 Group Assy at the correct insertion position.
7. Push the 3 Group Assy until the three claws lock.
OK
NG
DSC-QX10
4-16
Fold inside
Draw up
A
Gear A
Gear A
Gear B
Gear Worm
Wheel
Rear Mirror
Plate
Z Retainer
Screws
Screw
Flexible Board
Sensor
LF-139 Flexible Board
Ribs
Rib
Rib
Rib
Boss
Boss
Boss
Boss
11. Turn the Gear in the arrow direction to extend the Mirror Plate slightly.
12. Turn portion A in the arrow direction to TELE end and remove the Flexible Board from the hole in the Stationary Tube Assy.
13. Install the Gear Worm Wheel, Gear A, and Gear B.
14. Install the Rear Mirror Plate.
15. Install four screws and the Z Retainer. Tighten the screws in the order of numbers in the figure below.
16. Install the LF-139 Flexible Board.
1
2
3
4
DSC-QX10
4-17
Connector
Flexible Board
Claws
Sensors
OK
NG
FG Leaf
Spring
FG Leaf Spring
FG Leaf Spring
Claw
FPC Retainer
Flexible Board
FPC Tape
FPC Tape
Rib
Connector
17. Connect the two Flexible Boards to the Connectors on the LF-139 Flexible Board.
18. Stick the FPC Tape as shown in the figure below.
19. Install the two Sensors and attach the FG Leaf Spring.
      Note: Attach the FG Leaf Spring in the correct orientation.
20. Attach the FPC Retainer.
21. Apply a voltage of 2.5 V to the DC Motor and retract the Lens.
22. Perform the Flange Back Adjustment after the assembling.
DC2.5V
DSC-QX10
4-18
4-4-2.   Final Inspection
(1) Confirm There Is No Fault In Actual Motion/Actual Screen
Inspect it as follows when you exchange parts in the lens block.
Zoom motion (Check five postures: horizontal, upward/downward, upper/lower oblique 45º)
No abnormal sound or motion must be found over full stroke between TELE end and WIDE end.
Zoom image
No abnormality such as a skipped image or wavy image must be found in the image through LCD or finder over full stroke between
TELE end and WIDE end.
Barrier (Check five postures: horizontal, upward/downward, upper/lower oblique 45º)
The barrier must be opened and closed fully, free from a sticking in the midway.
No abnormal sound must be heard during the operation.
Appearance condition
Scratches or stains must not be noticeable, except that the customer permits them.
Foreign matters on the lens
The lens condition must not be worse than that when the camera was received from the customer.
Lens at TELE end
Lens at WIDE end
Upward
Downward
Horizontal
Lower oblique
Full stroke check
1
2
3
4