3-1
3. SERVICE  NOTE
3-1.  PRECAUTION ON REPLACING THE SY-1024 BOARD
DESTINATION DATA
When you replace to a board for service, the written destination data of the board for service also might be changed to original setting.
Start the Adjust Manual in the Adjust Station and execute the “Destination data write”.
RESTORE DATA
When you replace to a board for service, get the data from the former one.
Start the Adjust Manual in the Adjust Station and execute the “RESTORE DATA” to get the data. 
The data getting for this model is as follows.
• PRODUCT ID & USB SERIAL No.
• Angular Velocity Sensor sensitivity
• AWB standard data input & check, Color reproduction check
USB Serial No. and Product ID
The unit is shipped after an ID (USB Serial No.) unique to each unit and an ID (Product ID) unique to each model have been written.
These IDs have not been written in a new board for service, and therefore they must be entered after the board replacement.
After the board has been replaced with a board for service, start the Adjust Manual in the Adjust Station and execute the “PRODUCT ID & 
USB SERIAL No. INPUT” and enter these IDs.
Note: 
A newly entered Product ID is not always equal to the ID before board replacement. If the new ID differs from the previous ID, it may cause a difference 
from the ID registered by the customer.
Update of MAC Address
When replacing the SY board, the CPU’s unique number (MAC address) must be reloaded. Perform the following procedure to reload the 
CPU’s unique number (MAC address).
1.  Download the latest-version Adjust manual from the TISS homepage.
2.  Install the downloaded Adjust manual.
3.  Execute “Wireless LAN check” on the ADJUST tab.
If “Wireless LAN check” is not executed and the backup data before replacement is restored, the MAC address in the Wi-Fi module does not 
match the MAC address in the flash memory, causing an error during Wi-Fi transfer.
Password required for Wi-Fi connection
A password required for Wi-Fi connection is recorded in every SY board. A label to present the password to the customer is stuck to every SY 
board for service. When the SY board is replaced, attach this label to the unit to be sent back.
Note:  The new SSID and password can be checked on the PC connected to the unit with a USB cable.
 [Computer] 
→ [PMHOME] → [INFO] → [WIFI_INF.TXT]
Applicable parts
• SY-1024 BOARD, COMPLETE (SERVICE)
Note:  The [DATA LOAD AND WRITE] function in “ADJUSTMENT DATA BACKUP” on the DATA tab in the Adjust manual overwrites all data of the 
unit. Therefore, the MAC address updated during the above procedure is also overwritten. Perform the above operations “Update of MAC Address” 
after all work has been done.
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, down-
load the Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) from the TISS homepage and print out it, and attach it to the set when 
returning the set to customer.
Angular Velocity Sensor
When you replace to a board for service, write down the sensitivity displayed on the angular velocity sensor (SE401).
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity ADJ”.
P: PITCH sensor sensitivity
Y: YAW sensor sensitivity
Type A:
Type B:
Y P
Y P
SY-1024 BOARD (SIDE A)
SE401
(PITCH/YAW)
Note: The sensor sensitivity of SE401 of SY-1024 board is written only service part.
– ENGLISH –
DSC-QX10
3-2
3-2.  PRECAUTION ON REPLACING THE 
LENS
When replacing the lens, read the QR code given on the data sheet 
of the replacement lens for service.
Start the Adjust Manual and read the QR code using a QR code reader.
The read data is used for adjustment after replacement.
Select “Lens data carry” on the ADJUST tab of the Adjust Manual, 
and click the LOAD button to load the file.
QR code
3-3.  NOTES FOR FLEXIBLE BOARD
Make sure that the conductive side of a flexible board does not have any stain or foreign materials.
Do not touch the conductive side of flexible boards with bare hands.
Plug in a flexible board straight, fully into the connector until it reaches the end inside. (Fig. 1, Fig. 2, Fig. 3)
OK 
(The flexible board was plugged in straight 
and completely)
NG 
(The flexible board was plugged in 
crooked.)
NG 
(The flexible board was not plugged in 
completely.)
Flexible
Board
Flexible
Board
Connector
Connector
Reference line
Flexible
Board
Connector
Connector
Flexible
Board
Reference line
Connector
Connector
Flexible
Board
Flexible
Board
Reference line
Fig. 1
Fig. 2
Fig. 3
When opening the connector's holder in direction A, do not open 
it with excessive force.
When closing the connector's holder, press it evenly while pushing 
a flexible board in direction B.
Holder
Connector
Flexible Board
A
A
Holder
Insulation side
Connector
Flexible Board
B
•  Make sure that the flat cable and flexible board are not cracked 
or bent at the contact end.
•  Do not apply excessive force to the gilded flexible board.
Cut and remove the part of gilt
which comes off at the point.
(Be careful or some
pieces of gilt may be left inside)
•  The proper way to disconnect a connector is to grab the con-
nector instead of the wires.  If you pull on the wires, they might 
be broken.
•  The proper way to connect a connector is to grab the connector 
instead of the wires.  If you push on the wires, they might be 
broken.
– ENGLISH –
DSC-QX10
3-3
3-4.  CHECKING THE Wi-Fi FUNCTION
Perform the following procedure to check the Wi-Fi function.
Required equipment: Windows personal computer with Wi-Fi interface
1.  Turn on the power of the unit.
2.  Check the SSID and password by following procedure.
Procedure 1:  Check the label on the inside of the battery lid.
Procedure 2:  Check the seal on the cover of the manual.
Procedure 3:  Connect the unit and a PC with the micro USB cable, then select [Computer] → [PMHOME] → “WIFI_INF.TXT” of 
[INFO].
3.  Confirm on the PC that the unit is detected as a connectable wireless network.
4.  To further confirm that the unit is connectable, connect the unit to the PC and select “Network and Internet” → “Manage Wireless Networks” 
from Control Panel to open the network connection list. The unit is included in the list.
 
– ENGLISH –
DSC-QX10
3-4
3-1.  SY-1024基板交換時の注意
仕向けデータ
補修用基板と交換する際,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「Destination data write」を実行させてください。
リストアデータ
補修用基板と交換する際,交換前の基板よりデータを取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「RESTORE DATA」を実行させてください。
本機で取得されるデータは下記になります。
・ PRODUCT ID & USB SERIAL No.
・ Angular Velocity Sensor sensitivity
・ AWB standard data input & check, Color reproduction check
USBシリアルNo.およびプロダクトIDについて
本機はセット固有のID(USBシリアルNo.)と機種固有のID(プロダクトID)を書き込んだ後に出荷されています。
新品の補修用基板にはこれらのIDが書き込まれていないため,基板交換後にIDを入力する必要があります。
補修用基板に交換した後はAdjust StationからAdjust Manualを起動し,「PRODUCT ID & USB SERIAL No. INPUT」を実行させて
IDを入力してください。
Note: 
 新しくプロダクトIDを入力すると,必ずしも基板交換前のIDと同じIDになるとは限りません。新しいIDと元のIDが違う場合にはお客
様がユーザー登録されているIDと相違が出てしまう可能性があります。
MACアドレスの更新
SY基板を交換した場合,CPUの固有番号  (MACアドレス)  を取り込み直す必要があります。補修用基板に交換後は下記の作業を
実施して,CPUの固有番号 (MACアドレス) を取り込み直してください。
1.  TISSホームページより最新版のAdjust manualをダウンロードする。
2.  ダウンロードしたAdjust manualをインストールする。
3.  ADJUSTタブにある「Wireless LAN check」を実施する。
これを実行せずに交換前のバックアップデータを書き戻すと,Wi-Fiモジュール内のMACアドレスとフラッシュメモリー内の
MACアドレスが不一致となり,Wi-Fi転送時にエラーとなります。
Wi-Fi接続に必要なパスワード
SY基板にはWi-Fi接続に必要なパスワードが記録されています。また,補修用SY基板にはそのパスワードをお客様へ提示するた
めのシールが貼られております。SY基板を交換した場合は,このシールを返却するセットに添付してください。
Note: 
新しいパスワードはセットとPCをUSB接続することで確認できます。
 
 
[コンピュータ] → [PMHOME] → [INFO] → [WIFI_INF.TXT]
対象となる部品
・ SY-1024 BOARD, COMPLETE (SERVICE)
Note: 
 Adjust manualのDATAタブにある「ADJUSTMENT DATA BACKUP」の機能 [DATA LOAD AND WRITE] は,セットの全てのデータを上
書きします。そのため,上記の操作で更新したMACアドレスも上書きされてしまいます。上記の「MACアドレスの更新」は全ての作
業が終わった後に行ってください。
交換修理後はMACアドレスが変更されていますので,お客様に接続機器の再設定をしていただく必要があります。
そのためTISSホームページよりFlyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) をダウンロードしてプリント出力
し,セットに添付して返却してください。
角速度センサ
補修用基板と交換する時,角速度センサ(SE401)の感度表示を書き留めてください。
Adjust StationからAdjust Manualを起動させて「Angular velocity sensor sensitivity ADJ」を実行させてください。
P: PITCH 感度表示
Y: YAW 感度表示
Type A:
Type B:
Y P
Y P
SY-1024 BOARD (SIDE A)
SE401
(PITCH/YAW)
Note:SY-1024基板のSE401感度表示は補修用基板にしか記載されておりません。
– JAPANESE –
Page of 39
Display

Click on the first or last page to see other DSC-QX10 service manuals if exist.