Sony DSC-P2 (serv.man2) Service Manual ▷ View online
DSC-P2
5-29
19. CCD Black Defect Compensation
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of page: 6,
address: 55
address: 55
Measuring Instrument
Adjusting remote commander
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Check that there are no dust, no dirt and reflection of the
clear chart.
clear chart.
Note 3:
Any subject other than the clear chart should be in the
screen.
screen.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
camera system adjustment”.
(Refer to page 5-14)
2
E
65
Note down the data.
3
E
65
4C
Press PAUSE button.
4
6
2C
01
5
6
90
00
6
6
91
03
7
6
92
00
8
6
93
00
9
6
01
79
Press PAUSE button.
10
6
30
08
11
6
07
Check the data changes to
“01”.
“01”.
12
Wait for 4 seconds.
13
6
01
8D
Press PAUSE button.
14
6
02
Check the data changes to
“01”.
“01”.
15
6
55
Check the data.
00 to 14 : Normal
15 to FF : Defective
(Note 4)
00 to 14 : Normal
15 to FF : Defective
(Note 4)
16
6
01
00
Press PAUSE button.
17
E
65
5A
Press PAUSE button.
18
6
01
89
Press PAUSE button.
19
6
02
Check the data changes to
“01”.
“01”.
20
6
55
Check the data.
00: Normal
01 to FF: Defective
00: Normal
01 to FF: Defective
Note 4:
If the data is “00” at the check in this adjustment method
order #15, skip the orders from #16 to #20 , and go for-
ward to “Processing after Completing Adjustment.
order #15, skip the orders from #16 to #20 , and go for-
ward to “Processing after Completing Adjustment.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
30
00
4
6
91
00
5
E
65
Set data noted down at step
2, and press PAUSE button.
2, and press PAUSE button.
6
Release the data setting
performed at step 1.
(Refer to page 5-14)
performed at step 1.
(Refer to page 5-14)
DSC-P2
5-30
20. Strobe White Balance Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance when the strobe light flashed.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
Paper which reflection rate is
18% (Note 6)
(50 cm from the front of lens)
Paper which reflection rate is
18% (Note 6)
(50 cm from the front of lens)
Measurement Point
Displayed data of page: 1 (Note
4) and page: F, address: E8, EA,
EC, EE
4) and page: F, address: E8, EA,
EC, EE
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
B6, B7, DB to EF
Specified Value
Y level data: 03 to 08
R-Y level data:
007C to 0084 (Note 4)
B-Y level data:
007C to 0084 (Note 4)
R-Y level data:
007C to 0084 (Note 4)
B-Y level data:
007C to 0084 (Note 4)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
(See page 5-7)
(See page 5-7)
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
adjusting remote commander.
1:XX:XX
Displayed data
Note 5:
“Strobe White Balance Adjustment” is available only
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
once after the power is turned on. Turn the power off,
then on again if the adjustment is retried.
Note 6:
Background paper (J-2501-130-A).
Switch setting:
1) FLASH (Control button) .............. ON
1) FLASH (Control button) .............. ON
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (Refer to page 5-15)
setting”. (Refer to page 5-15)
3
4
1E
Note down the data.
4
4
1E
00
5
6
2C
01
6
6
90
00
7
6
91
00
8
6
92
FF
9
6
93
FF
10
6
6C
01
11
6
01
79
Press PAUSE button.
12
6
07
Check the data changes to
“01”.
“01”.
13
6
01
67
Press PAUSE button.
14
Check the flashing.
15
6
02
Check the data changes to
“01”.
“01”.
16
F
E8
Check that the displayed data
satisfies the Y level specified
value.
satisfies the Y level specified
value.
17
6
01
00
Press PAUSE button.
18
6
90
E0
19
6
91
01
20
6
01
79
Press PAUSE button.
21
6
07
Check the data changes to
“01”.
“01”.
22
6
01
67
Press PAUSE button.
23
Check the flashing.
24
6
02
Check the data changes to
“01”.
“01”.
25
6
01
00
Press PAUSE button.
26
6
90
00
27
6
91
00
28
6
01
79
Press PAUSE button.
29
6
07
Check the data changes to
“01”.
“01”.
30
6
01
67
Press PAUSE button.
31
Check the flashing.
32
6
02
Check the data changes to
“01”.
“01”.
33
6
01
00
Press PAUSE button.
34
6
90
20
35
6
91
02
36
6
01
67
Press PAUSE button.
37
Check the flashing.
38
6
07
01
39
6
01
67
40
Check the flashing.
DSC-P2
5-31
Order Page Address Data
Procedure
41
6
02
Check the data changes to
“01”.
“01”.
42
6
01
00
Press PAUSE button.
43
6
90
00
44
6
91
00
45
6
01
79
Press PAUSE button.
46
6
07
Check the data changes to
“01”.
“01”.
47
6
01
B9
Press PAUSE button. (Note 6)
48
Check the flashing.
49
6
02
Check the data changes to
“01”.
“01”.
50
6
01
00
Press PAUSE button.
51
6
01
E7
Press PAUSE button.
52
Check the flashing.
53
6
02
Check the data changes to
“01”.
“01”.
EA
Check that the displayed data
54
F
EC
satisfies the Y level specified
EE
value.
55
0
03
2C
56
1
Check that the R-Y level data
(Note 4) satisfies the specified
value.
(Note 4) satisfies the specified
value.
57
0
03
2D
58
1
Check that the B-Y level data
(Note 4) satisfies the specified
value.
(Note 4) satisfies the specified
value.
Note 6:
The adjustment data will be automatically input to page:
F, address: B6 to B7 and DB to EF.
F, address: B6 to B7 and DB to EF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
6
6
2C
00
7
6
6C
00
8
0
03
00
9
4
1E
Set data noted down at step
3, and press PAUSE button.
3, and press PAUSE button.
10
Release the data setting
performed at step 1.
(Refer to page 5-14)
performed at step 1.
(Refer to page 5-14)
DSC-P2
5-32
21. AF Illumination Check
RadarW
RadarW
RadarW
RadarW
RadarW
Check the deviation of optical axis of AF illuminator.
Mode
CAMERA
Subject
Flash adjustment box (Note 3)
(50 cm or 1 m from the front of
lens)
(50 cm or 1 m from the front of
lens)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Note 1:
Perform checking by making the shooting surface of the
Flash adjustment box perpendicular to the optical axis of
the camera.
Flash adjustment box perpendicular to the optical axis of
the camera.
Note 2:
Perform this checking in the Flash adjustment box.
Restrict external light to enter the Flash adjustment box
as less as possible.
Restrict external light to enter the Flash adjustment box
as less as possible.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
(See page 5-7)
(See page 5-7)
Switch setting
1) FOCUS (Menu setting) .............................. MULTI AF
1) FOCUS (Menu setting) .............................. MULTI AF
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
camera system adjustment”.
(Refer to page 5-14)
2
9
A9
Set the following data, and
press PAUSE button.
06: 50 cm
04: 1 m
press PAUSE button.
06: 50 cm
04: 1 m
3
6
01
EF
Press PAUSE button.
4
6
02
Check the data changes to
“01”.
“01”.
5
F
10
Check the data.
00: Normal
01 to FF: Defective
00: Normal
01 to FF: Defective
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 1.
(Refer to page 5-14)
performed at step 1.
(Refer to page 5-14)
Click on the first or last page to see other DSC-P2 (serv.man2) service manuals if exist.