DOWNLOAD Sony DSC-P2 (serv.man2) Service Manual ↓ Size: 2.97 MB | Pages: 96 in PDF or view online for FREE

Model
DSC-P2 (serv.man2)
Pages
96
Size
2.97 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-p2-sm2.pdf
Date

Sony DSC-P2 (serv.man2) Service Manual ▷ View online

DSC-P2
5-21
9.
Auto White Balance 3200K Standard Data Input 2
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
78 to 7F
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
04
6
6
01
0B
Press PAUSE button. (Note 3)
7
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 78 to 7F.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
Set data noted down at step 3,
and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 5-14)
10. Auto White Balance 3200K Standard Data Input 3
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the white balance standard data at 3200K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page
F
Adjustment Address
80 to 87
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 3200K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
6
37
06
6
6
01
0B
Press PAUSE button. (Note 3)
7
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 80 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
37
00
3
6
B6
Set data noted down at step 3,
and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 5-14)
DSC-P2
5-22
11. Auto White Balance 3200K Check
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data
Video terminal of
of Page: 1
A/V OUT jack
(Note 2)
(75 
 terminated)
Specified Value
R ratio: 3FA0 to 4060
B ratio: 3FA0 to 4060
R-Y level data: 7E to 82
B-Y level data: 7E to 82
Y level data: 10 to 40
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (WIDE end)
(Refer to page 5-15)
3
6
B6
Note down the data.
4
6
B6
03
5
7
5D
Note down the data.
6
7
5D
00
Press PAUSE button.
7
7
9D
Note down the data.
8
7
9D
80
Press PAUSE button.
9
6
37
0D
10
6
01
11
Press PAUSE button.
11
6
38
Check the data changes to
“01”.
12
6
01
C1
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
0
03
04
15
1
Check that the displayed data
(Note 2) satisfied the R ratio
specified value.
16
0
03
05
17
1
Check that the displayed data
(Note 2) satisfied the B ratio
specified value.
18
0
03
2C
19
1
Check that the R-Y level data
(Note 2) satisfied the
specified value.
20
0
03
2D
21
1
Check that the B-Y level data
(Note 2) satisfied the
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
7
5D
Set data noted down at step
5, and press PAUSE button.
3
7
9D
Set data noted down at step
7, and press PAUSE button.
4
0
03
00
5
6
37
00
6
6
B6
Set data noted down at step
3, and press PAUSE button.
7
F
74
Check that the displayed data
76
the Y level specified value.
7C
7E
84
86
8
Release the data setting
performed at step 1.
(Refer to page 5-14)
DSC-P2
5-23
12. Auto White Balance 5800K Standard Data Input 1
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end and
TELE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
88 to 8F, A0 to A3, B1, B3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 5800K Standard Data Input 1” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
3
Perform “Picture Frame
setting”. (WIDE end)
(Refer to page 5-15)
4
F
A0
29
Press PAUSE button.
5
F
A1
C0
Press PAUSE button.
6
F
A2
5F
Press PAUSE button.
7
F
A3
80
Press PAUSE button.
8
6
B6
Note down the data.
9
6
B6
03
10
7
5D
Note down the data.
11
7
5D
00
Press PAUSE button.
12
7
9D
Note down the data.
13
7
9D
80
Press PAUSE button.
14
6
37
07
15
6
01
11
Press PAUSE button.
16
6
38
Check the data changes to
“01”.
17
6
01
C3
Press PAUSE button. (Note 3)
18
6
02
Check the data changes to
“01”.
19
7
5D
Set data noted down at step
10, and press PAUSE button.
20
7
9D
Set data noted down at step
12, and press PAUSE button.
21
6
01
00
Press PAUSE button.
22
Perform “Picture Frame
setting”. (TELE end)
(Refer to page 5-15)
23
B
70
Note down the data.
24
B
70
10
Press PAUSE button.
25
6
37
08
RadarW
RadarW
RadarW
RadarW
RadarW
Order Page Address Data
Procedure
26
6
01
A5
Press PAUSE button. (Note 3)
27
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 88 to 8F, A0 to A3, B1 and B3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
37
00
2
6
01
00
Press PAUSE button.
3
B
70
Set data noted down at step
23, and press PAUSE button.
4
6
B6
Set data noted down at step
8, and press PAUSE button.
5
Release the data setting
performed at step 2.
(Refer to page 5-14)
6
Remove the C14 filter on the
lens.
DSC-P2
5-24
14. Auto White Balance 5800K Standard Data Input 3
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
98 to 9F, A0 to A3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 5800K Standard Data Input 3” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
3
Perform “Picture Frame
setting”. (Refer to page 5-15)
4
F
A0
29
Press PAUSE button.
5
F
A1
C0
Press PAUSE button.
6
F
A2
5F
Press PAUSE button.
7
F
A3
80
Press PAUSE button.
8
6
B6
Note down the data.
9
6
B6
03
10
B
70
Note down the data.
11
B
70
10
12
6
37
0C
13
6
01
A5
Press PAUSE button. (Note 3)
14
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 98 to 9F and A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
37
00
2
6
01
00
Press PAUSE button.
3
B
70
Set data noted down at step
10, and press PAUSE button.
4
6
B6
Set data noted down at step 8,
and press PAUSE button.
5
Release the data setting
performed at step 2.
(Refer to page 5-14)
6
Remove the C14 filter on the
lens.
RadarW
RadarW
RadarW
RadarW
RadarW
13. Auto White Balance 5800K Standard Data Input 2
Adjust the white balance standard data at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
Adjustment Address
90 to 97, A0 to A3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Auto White Balance 5800K Standard Data Input 2” is
available only once after the power is turned on. Turn the
power off, then on again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
3
Perform “Picture Frame
setting”. (Refer to page 5-15)
4
F
A0
29
Press PAUSE button.
5
F
A1
C0
Press PAUSE button.
6
F
A2
5F
Press PAUSE button.
7
F
A3
80
Press PAUSE button.
8
6
B6
Note down the data.
9
6
B6
03
10
B
70
Note down the data.
11
B
70
10
12
6
37
0A
13
6
01
A5
Press PAUSE button. (Note 3)
14
6
02
Check the data changes to
“01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 90 to 97and A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
37
00
2
6
01
00
Press PAUSE button.
3
B
70
Set data noted down at step
10, and press PAUSE button.
4
6
B6
Set data noted down at step
8, and press PAUSE button.
5
Release the data setting
performed at step 2.
(Refer to page 5-14)
6
Remove the C14 filter on the
lens.
RadarW
RadarW
RadarW
Page of 96
Display

Click on the first or last page to see other DSC-P2 (serv.man2) service manuals if exist.