DSC-P2
5-25
Order Page Address Data
Procedure
22
1
Check that the displayed data
(Note 2) satisfied the B ratio
2 specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
7
5D
Set data noted down at step
6, and press PAUSE button.
2
7
9D
Set data noted down at step
8, and press PAUSE button.
3
6
01
00
Press PAUSE button.
4
0
03
00
5
6
37
00
6
6
B6
Set data noted down at step
4, and press PAUSE button.
7
Remove the C14 filter on the
lens.
8
F
8C
Check that the displayed data
94
the Y level 1 specified value.
9C
9
F
8E
Check that the displayed data
96
the Y level 2 specified value.
9E
10
Release the data setting
performed at step 2.
(Refer to page 5-14)
15. Auto White Balance 5800K Check
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Displayed data of Video terminal of
Page: 1
A/V OUT jack
(Note 2)
(75 
 terminated)
Specified Value
R ratio 1: 2960 to 2A20
B ratio 1: 5F20 to 5FE0
R ratio 2: 2920 to 2A60
B ratio 2: 5EE0 to 6020
Y level 1 data: 0E to 40
Y level 2 data: 10 to 40
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Place the C14 filter on the
lens.
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
3
Perform “Picture Frame
setting”. (Refer to page 5-15)
4
6
B6
Note down the data.
5
6
B6
03
6
7
5D
Note down the data.
7
7
5D
00
Press PAUSE button.
8
7
9D
Note down the data.
9
7
9D
80
Press PAUSE button.
10
6
37
13
11
6
01
11
Press PAUSE button.
12
6
38
Check the data changes to
“01”.
13
6
01
C3
Press PAUSE button.
14
6
02
01
15
0
03
04
16
1
Check that the displayed data
(Note 2) satisfied the R ratio
1 specified value.
17
0
03
05
18
1
Check that the displayed data
(Note 2) satisfied the B ratio
1 specified value.
19
0
03
2C
20
1
Check that the displayed data
(Note 2) satisfied the R ratio
2 specified value.
21
0
03
2D
DSC-P2
5-26
16. CCD Linearity Check
RadarW
RadarW
RadarW
Check that CCD output keeps being straight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Displayed data of Page: 1 (Note 1)
Measuring Instrument
Adjusting remote commander
Specified Value
R ratio: 3D00 to 4300
B ratio: 3D00 to 4300
Note 1:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
setting”. (Refer to page 5-15)
3
6
37
23
4
6
01
0F
Press PAUSE button.
5
6
02
Check the data changes to
“01”.
6
0
03
04
7
1
Check that the displayed data
(Note 1) satisfied the R ratio
specified value.
8
0
03
05
9
1
Check that the displayed data
(Note 1) satisfied the B ratio
specified value.
10
6
01
00
Press PAUSE button.
11
7
10
Note down the data.
12
7
10
FF
13
B
70
Note down the data.
14
B
70
40
15
6
37
24
16
6
01
0F
Press PAUSE button.
17
6
02
Check the data changes to
“01”.
18
0
03
04
19
1
Check that the displayed data
(Note 1) satisfied the R ratio
specified value.
20
0
03
05
21
1
Check that the displayed data
(Note 1) satisfied the B ratio
specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
7
10
Set data noted down at step
11, and press PAUSE button.
3
B
70
Set data noted down at step
13, and press PAUSE button.
4
6
37
00
5
6
01
00
Press PAUSE button.
6
Release the data setting
performed at step 1.
(Refer to page 5-14)
DSC-P2
5-27
17. Color Reproduction Adjustment
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Mode
CAMERA
Subject
Color bar chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
A4 to AF
Specified Value
All color luminance points
should settle within each color
reproduction frame.
Menu setting:
1)
VIDEO OUT of SET UP menu
................................
NTSC (NTSC mode)
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
“Color Reproduction Adjustment” is available only once
after the power is turned on. Turn the power off, then on
again if the adjustment is retried.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
Perform “Picture Frame
Setting”. (Refer to page 5-15)
3
6
01
AB
Press PAUSE button.
4
6
37
1F
5
6
01
A9
Press PAUSE button. (Note 3)
6
6
02
Check the data changes to
“01”.
7
6
37
20
8
Check the each color lumi-
nance point is in each color
reproduction frame.
Note 3:
The adjustment data will be automatically input to page:
F, address: A4 to AF.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
37
00
2
6
01
00
Press PAUSE button.
3
Release the data setting
performed at step 1.
(Refer to page 5-14)
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
Fig. 5-1-17
DSC-P2
5-28
18. CCD White Defect Compensation
RadarW
RadarW
RadarW
RadarW
RadarW
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
Measuring Instrument
Adjusting remote commander
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
The“CCD White Defect Compensation” should be made
when the set warms up at certain duration after the power
was turned on, as it is affected with the temperature.
Adjusting method:
Order Page Address Data
Procedure
1
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-14)
2
E
64
Note down the data.
3
E
64
1E
Press PAUSE button.
4
E
69
Note down the data.
5
E
69
09
Press PAUSE button.
6
6
01
8B
Press PAUSE button.
7
6
02
Check the data changes to
“01”.
8
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
9
6
01
00
Press PAUSE button.
10
E
64
0F
Press PAUSE button.
11
E
69
60
Press PAUSE button.
12
6
01
87
Press PAUSE button.
13
6
02
Check the data changes to
“01”.
14
6
55
Check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
E
64
Set data noted down at step
2, and press PAUSE button.
3
E
69
Set data noted down at step
4, and press PAUSE button.
4
Release the data setting
performed at step 1.
(Refer to page 5-14)