5-9
1-2-2.
Initialization of B, E, F, 7, 9 Page Data
1.
Initializing B, E, F, 7, 9 Page Data
Note:
If the B, E, F, 7, 9 Page data has been initialized,
“Modification of B, E, F, 7, 9 Page Data” and following
adjustments need to be performed again.
1) Modification of B, E, F, 7, 9 page data
2) Camera system adjustments
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Adjusting page
9
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
2
6
03
0A
3
6
00
2D
4
6
01
2D
Press PAUSE button.
5
6
02
Check the data changes to “01”.
6
Perform “Modification of B,
E, F, 7, 9 page Data”.
2.
Modification of B, E, F, 7, 9 Page Data
If the B, E, F, 7, 9 Page data has been initialized, change the data
of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camera may not operate.
3)
When changing the data, press the PAUSE button of the
adjusting remote commander each time when setting new data
to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7, 9
Page data
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
3.
B Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 6D
Fixed data-1 (Initialized data)
6E
Fixed data-2
6F to FF
Fixed data-1 (Initialized data)
4.
E Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 95
Fixed data-1 (Initialized data)
96
Fixed data-2
97 to FF
Fixed data-1 (Initialized data)
DSC-P2
5-10
5.
F Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to 0F
Fixed data-1 (Initialized data)
10
FF
AF Ilumination check.
11
FF
12
FF
13
FF
14
FF
15
FF
16, 17
Fixed data-1 (Initialized data)
18
36
Flange back adj.
19
54
1A
87
1B
71
1C
10
1D
C0
1E
00
1F
00
20
00
21
00
22
00
23
00
24
20
25
20
26
13
27
46
28
0A
29
00
2A
00
2B
00
2C
00
2D
00
2E
00
2F
00
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
3A
00
3B
00
3C
00
3D
00
Address
Initial value
Remark
3E
FF
Flange back adj.
3F
Fixed data-1 (Initialized data)
40
00
Flange back adj.
41
00
42
00
43
00
44
00
45
00
46
00
47
00
48
00
49
00
4A
00
4B
00
4C
00
4D
00
4E
00
4F
00
50
00
51
00
52
00
53
00
54 to 5D
Fixed data-1 (Initialized data)
5E
00
F No. compensation
5F
00
60
00
61
00
62
00
63
00
64
00
65
30
Light value adj.
66
FE
67
6D
68 to 6D
Fixed data-1 (Initialized data)
6E
00
Mixed color calcel adj.
6F
00
70
32
AWB 3200K standard data input 1
71
B2
72
23
73
64
74
32
75
6C
76
23
77
88
78
33
AWB 3200K standard data input 2
79
36
DSC-P2
5-11
Address
Initial value
Remark
7A
22
AWB 3200K standard data input 2
7B
2C
7C
32
7D
68
7E
23
7F
DF
80
33
AWB 3200K standard data input 3
81
93
82
22
83
7F
84
32
85
E2
86
25
87
12
88
20
AWB 5800K standard data input 1
89
F5
8A
33
8B
14
8C
20
8D
E2
8E
33
8F
89
90
21
AWB 5800K standard data input 2
91
69
92
32
93
62
94
21
95
52
96
33
97
94
98
21
AWB 5800K standard data input 3
99
52
9A
30
9B
80
9C
23
9D
A8
9E
33
9F
C3
A0
29
AWB 5800K standard data input 1, 2, 3
A1
C0
A2
F5
A3
80
A4
03
Color reproduction adj.
A5
E9
A6
63
A7
83
A8
D5
A9
FE
AA
73
Address
Initial value
Remark
AB
45
Color reproduction adj.
AC
63
AD
83
AE
03
AF
E9
B0
00
AWB 3200K standard data input 1
B1
00
AWB 5800K standard data input 1
B2
00
AWB 3200K standard data input 1
B3
00
AWB 5800K standard data input 1
B4
00
AWB 3200K standard data input 1
B5
Fixed data-1 (Initialized data)
B6
28
Strobe white balance adj.
B7
6E
B8
10
Mechanical shutter adj.
B9
6B
BA
0F
BB
F6
BC
00
BD
00
BE
00
BF
00
C0
00
C1
00
C2
00
C3
00
C4
00
C5
00
C6
00
C7
30
C8
1B
C9
00
CA
00
CB
00
CC
80
CD
90
CE
98
CF
90
D0
88
D1
00
D2
00
D3
00
D4
00
D5
00
D6
00
D7
14
D8 to DA
Fixed data-1 (Initialized data)
DB
00
Strobe white balance adj.
DC
00
DD
00
DSC-P2
5-12
Address
Initial value
Remark
DE
00
Strobe white balance adj.
DF
00
E0
00
E1
00
E2
00
E3
00
E4
00
E5
00
E6
00
E7
00
E8
00
E9
00
EA
00
EB
00
EC
00
ED
00
EE
00
EF
00
F0 to FF
Fixed data-1 (Initialized data)
6.
7 Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
7.
9 Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing B, E, F, 7, 9 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modification of B, E, F, 7, 9 Page Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
Page of 96
Display

Click on the first or last page to see other DSC-P2 (serv.man2) service manuals if exist.