Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h5-sm3.pdf
Date

Sony DSC-H5 (serv.man3) Service Manual ▷ View online

6-24
DSC-H5_ADJ
11. CAMERA Adjustment 7
Perform this adjustment only when replacing the angular velocity
sensor. When the microprocessor, circuit etc. is damaged, don't per-
form this adjustment but check the operations only.
Note down the sensitivity displayed on the angular velocity sensor of
the repair parts. At this time, note down also to which board it was
attached to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Page
CF
Adjustment Address
0C, 0D
Note 1: The sensor sensitivity of SE501 and SE502 of the SY-
150 board is written only repair parts.
Preparation:
1) Read the PITCH sensor (SY-150 board SE501) sensitivity writ-
ten on repair parts, and named this as S
501
.
2) Read the YAW sensor (SY-150 board SE502) sensitivity writ-
ten on repair parts, and named this as S
502
.
Fig. 6-1-49
SE501
SE502
SY-150 BOARD (SIDE A)
XX
XX
YAW sensor sensitivity    
t S
502
PITCH sensor sensitivity 
t S
501
[Adjusting method]
1) Click the [Start] button of Camera Adjustment 7, and the fol-
lowing screen will appear.
Fig. 6-1-50
2) Input the sensitivity of respective sensors (S
501
, S
502
) read at
“Preparation” into the screen.
If only either sensor was replaced, give a check to the checkbox
for the sensor not replaced at the lower left of the screen.
3) Click the [OK] button, and the adjustment data is then calcu-
lated from the sensor sensitivity value and the calculation re-
sult is written to the memory in the camera.
4) Upon successful completion of the data writing, the following
screen will appear. Check that the steady shot function oper-
ates normally.
Fig. 6-1-51
6-25
DSC-H5_ADJ
1-5-2.
Adjustment Items of LCD System Adjustment
The adjustment items of LCD system adjustment are as listed in
Table 6-1-4. The Automatic Adjustment Program executes the ad-
justment items if the LCD Adjustment Start button is clicked.
Button
Adjustment
Signal
Page
Address
Name
LCD
V-COM adj.
8F
11
Adjustment White Balance adj.
Arbitrary
8F
42, 43, 58, 59
Table 6-1-4
1-5.
LCD  SYSTEM  ADJUSTMENTS
1-5-1.
Function of Each Button on LCD System
Adjustment Screen
Click the [LCD SYSTEM ADJUSTMENT] button on the Main Menu
screen, and the “LCD SYSTEM ADJUSTMENT” screen in Fig.
6-1-52 will appear.
Fig. 6-1-52
1
[To Menu] button
The Main Menu screen comes back.
2
[Start] button
“LCD Adjustment” starts.
3
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
4
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the LCD adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
4
3
2
1
6-26
DSC-H5_ADJ
6) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
Fig. 6-1-55
SEUS operation screen
Fig. 6-1-56
Check on the LCD screen (V-COM Adj.)
Fig. 6-1-57
1-5-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj. & EVR Data Write
2. V-COM Adj.
3. White Balance Adj.
4. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes “1. Data Setting
during LCD Adj. & EVR Data Write”.
3) Upon successful completion of the “1. Data Setting during LCD
Adj. & EVR Data Write”, the following message is displayed
during execution in “2. V-COM Adj.”. On the SEUS screen,
operate the UP/DOWN key so that the brightness of portions
A and B on the LCD panel is equal. After the adjustment, click
the [OK] button.
Fig. 6-1-53
4) Upon completion of “2. V-COM Adj.”, the following screen is
displayed during the execution of “3. White Balance Adj.”.
Check that the LCD screen is not colored. If colored, using the
[Up]/[Down] button on the screen, adjust so that the LCD screen
is not colored. After the adjustment, click the [End] button in
the screen.
Fig. 6-1-54
5) If the [End] button is clicked, “4. Release of Data Setting dur-
ing LCD Adj.” will be executed.
UP/DOWN key
A
B
6-27
DSC-H5_ADJ
1-6.
ERROR
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-6-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error
Fig. 6-1-58
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SEUS is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SEUS and click the [Connect] to check
that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-59
Symptom
The camera is not ready for adjustment.
Cause
• Data error exists in the camera.
Remedy
• Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-60
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-61
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.