DOWNLOAD Sony DSC-H5 (serv.man3) Service Manual ↓ Size: 714.63 KB | Pages: 36 in PDF or view online for FREE

Model
DSC-H5 (serv.man3)
Pages
36
Size
714.63 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h5-sm3.pdf
Date

Sony DSC-H5 (serv.man3) Service Manual ▷ View online

6-11
DSC-H5_ADJ
1-2-2.
AWB Adjustment Program
1.
Application Environment
OS:
Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
2.
Installation Method
Extract the file compressed in the ZIP format (H5AWBAdjustment.zip).
Execute the extracted file (setup.exe), and the installer will start. Install
the program following the instructions given on the installer screen.
3.
Notes When Using the AWB Adjustment Program
1) The SEUS must be installed in the PC.
2) The HASP Key for SEUS must be connected to the USB con-
nector. The program will not start unless the HASP Key is
connected.
4.
Starting Method of AWB Adjustment Program
Click the [Start] button on the task bar, and click the [DSC-H5 AWB
Adjustment] from the [Programs], and the program will start.
5.
Screen and Function of Each Button of AWB
Adjustment Program
Fig. 6-1-11
1
[Connect] button
Makes connection to the camera and switches the camera to
the adjustment mode. In the case of successful connection to
the camera, the indication at the part A changes to “Connected”
and the following buttons become active.
• [AWB 3200K-5800K Standard Data Input] button
• [Disconnect] button
2
Adjustment start buttons
Start the adjustment or checking of respective button names.
3
[Disconnect] button
Cancels the connection to the camera.
4
Captured picture display screen
Displays a picture captured by the camera when the adjust-
ment or checking was performed.
4
3
2
1
A
6-12
DSC-H5_ADJ
1-3.
VIDEO  SYSTEM  ADJUSTMENTS
1-3-1.
Function of Each Button on Video System
Adjustment Screen
Click the [VIDEO SYSTEM ADJUSTMENT] button on the Main Menu
screen, and the “VIDEO SYSTEM ADJUSTMENT” screen in Fig.
6-1-12 will appear.
Fig. 6-1-12
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs usd are displayed.
3
[Start] button
“Video Adjustment” starts.
4
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the video adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
1-3-2.
Adjustment Items of VIDEO System
Adjustment
The adjustment items of video system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program executes the ad-
justment items if the VIDEO Adjustment Start button is clicked.
Button
Adjustment
Signal
Page
Address
Name
VIDEO
VIDEO Output
Adjustment Level Adj.
Arbitrary
8F
D0
Table 6-1-2
5
4
3
2
1
6-13
DSC-H5_ADJ
SEUS operation screen
Fig. 6-1-15
Check on the oscilloscope
Fig. 6-1-16
1-3-3.
Adjusting Method
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Video Adj.
2. Video Output Level Adj.
3. Release of Data Setting during Video Adj.
[Specified value of video output level adj.]
Measurement Point
Video terminal of AV OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level:
A = 286 
± 5 mV (NTSC mode)
A = 300 
± 5 mV (PAL mode)
Burst level:
B = 286 
± 25 mV (NTSC mode)
B = 300 
± 25 mV (PAL mode)
[Adjusting method]
1) Click the [Start] button of the VIDEO Adjustment.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Video Adj.”.
3) If “1. Data Setting during Video Adj.” completed successfully,
the next message is displayed during the execution of “2. Video
Output Level Adj.”. Using the UP/DOWN key on the SEUS
Operation screen, adjust so that the sync level of the video
signals satisfies the specified value. After the adjustment, check
that the burst level of the video signals satisfies the specified
value, and click the [OK] button in the message.
Fig. 6-1-13
4) If the [OK] button button is clicked, “3. Release of Data Set-
ting during Video Adj.” will be executed.
5) Upon successful completion of all items of the VIDEO Ad-
justment, the following message is displayed. Click the [OK]
button.
Fig. 6-1-14
UP/DOWN key
H
A
B
6-14
DSC-H5_ADJ
1-4.
CAMERA  SYSTEM  ADJUSTMENTS
1-4-1.
Function of Each Button on Camera System
Adjustment Screen
Click the [CAMERA SYSTEM ADJUSTMENT] button on the Main
Menu screen, and the “CAMERA SYSTEM ADJUSTMENT”
screen in Fig. 6-1-17 will appear.
Fig. 6-1-17
1
[To Menu] button
The Main Menu screen comes back.
2
[Preparation] button
Notes for adjustment or jigs used are displayed.
3
[Start] button
Each adjustment from “Camera Adjustment 1” to “Camera
Adjustment 7” starts.
4
[Reset] button
This button functions same as the “Initialize” of the setup
screen.
5
[Release Data Setting] button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the camera adjust-
ment 1-7. If the adjustment completed successfully, the data
setting is automatically cancelled and the button color returns
to “white”.)
5
4
3
2
1
2
3
Page of 36
Display

Click on the first or last page to see other DSC-H5 (serv.man3) service manuals if exist.