Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h5-sm3.pdf
Date

Sony DSC-H5 (serv.man3) Service Manual ▷ View online

6-19
DSC-H5_ADJ
[Adjusting method]
1) If the [Start] button of the CAMERA Adjustment 1 is clicked,
the following message is displayed.
If “Wide Limit Adjustment” is necessary, click the [Cancel]
button to interrupt the Adjustment Program, and perform “2.
Wide Limit Adjustment”.
Fig. 6-1-22
2) If the [OK] button is clicked, the Automatic Adjustment Pro-
gram executes “1. Data Setting during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation of Flange Back Adj.”.
Fig. 6-1-23
4) If the [OK] button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
Fig. 6-1-24
4.
CAMERA Adjustment 2
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
Fig. 6-1-25
4) Click the 
[OK]
 button is clicked, “2. Flange Back Check” is
executed. The following messages are displayed, and then op-
erate the camera to make a check in accordance with the mes-
sages.
Fig. 6-1-26
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK]
 button.
Fig. 6-1-27
6-20
DSC-H5_ADJ
A
A
B
A = B
6.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. F No. Compensation
4. Measure Gain Adj.
5. Mechanical Shutter Adj.
6. Light Value Adj.
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-28 to
Fig. 6-1-30, set the subject and click the [OK] button.
Fig. 6-1-31
After that, the next message is displayed. Then, change the chart
in accordance with the message.
Fig. 6-1-32
4) Click the [OK] button, and the items from “3. F No. Compen-
sation” to “7. Release of Data Setting during Camera Adj.”
will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK] button.
Fig. 6-1-33
5.
Picture Frame Setting (Standard Picture Frame)
In the “CAMERA Adjustment 3”, “AWB 3200K-5800K Standard
Data Input” and “CAMERA Adjustment 4”, set the picture frame
so as to attain the positions shown in the following figure when
shooting the 9 colors chart.
Check on the oscilloscope
Measurement Point: Video terminal of AV OUT jack
(75
Ω terminated)
1. Horizontal period
Fig. 6-1-28
2. Vertical period
Fig. 6-1-29
Check on the monitor TV or the LCD screen
Fig. 6-1-30
V
B
C
C
C =
B
3
Transparent window
Effective picture frame
A
A
B
Blue
C14
Magenta
White
Cyan
Red
Yellow
Green
W14
C
C
B
C =
A = B
C14: Filter for AWB 5800K adjustment
A
2
B
3
6-21
DSC-H5_ADJ
7.
AWB 3200K-5800K Standard Data Input
[Adjustment method]
1) Start the AWB Adjustment Program (H5AwbAdjustment.exe).
2) Click the [Connect] button to set the camera to the adjustment
mode.
Fig. 6-1-34
3) Adjust the mode dial of the camera to “CAMERA” and set
MACRO mode. Shoot the 9 colors chart with the zoom at WIDE
end.
4) Adjust the camera direction and distance to set the picture
frame. (Refer to 5. Picture Frame Setting)
5) Click the [AWB 3200K-5800K Standard Data Input] button.
Fig. 6-1-35
6) A picture captured by the camera is displayed on the screen,
and the adjustment and checking are performed.
Fig. 6-1-36
Note: If the following message is displayed, the picture frame
setting is faulty. Check the picture frame, and then perform
readjustment.
Fig. 6-1-37
7) Upon successful completion of the adjustment, the following
message is displayed. Click the [OK] button.
Fig. 6-1-38
8) Perform the “Camera Adjustment 4” successively without turn-
ing off the power switch of the camera.
6-22
DSC-H5_ADJ
At this time, the following message is displayed, and click the
[Yes] button if the check result display at the upper right of
Color Reproduction Check screen is OK, or the [No] button if
NG.
Fig. 6-1-41
5) Upon successful completion of “3. Color Reproduction Adj.
& Check”, the following message is displayed. Change the
chart in accordance with the message.
Fig. 6-1-42
6) Click the [OK] button, and the items from “4. CCD Linearity
Check” to “7. Release of Data Setting during Camera Adj.”
will be executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
Fig. 6-1-43
8.
CAMERA Adjustment 4
Note: After executing the “AWB 3200-5800K Standard Data In-
put” perform the “CAMERA Adjustment 4” successively
without turning off the power switch of the camera.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting
3. Color Reproduction Adj. & Check
4. CCD Linearity Check
5. CCD White Defect Compensation Check
6. CCD Black Defect Compensation Check
7. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 4.
2) The Automatic Adjustment Program executes the “1. Data Set-
ting during Camera Adj.”.
3) Upon successful completion of “1. Data Setting during Cam-
era Adj.”, “2. Picture Frame Setting” is executed. The follow-
ing message is displayed, and then referring to Fig. 6-1-28 to
Fig. 6-1-30 (See page 6-20), set the subject and click the [OK]
button.
Fig. 6-1-39
4) After that, “3. Color Reproduction Adj. & Check” will be ex-
ecuted. Upon completion of adjustment, the check result is
displayed on the Color Reproduction Check screen.
Fig. 6-1-40