DOWNLOAD Sony DSC-H5 (serv.man3) Service Manual ↓ Size: 714.63 KB | Pages: 36 in PDF or view online for FREE

Model
DSC-H5 (serv.man3)
Pages
36
Size
714.63 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-h5-sm3.pdf
Date

Sony DSC-H5 (serv.man3) Service Manual ▷ View online

6-15
DSC-H5_ADJ
1-4-2.
Adjustment Items of Camera System Adjust-
ment
The adjustment items of camera system adjustment are as listed in
Table 6-1-3. The Automatic Adjustment Program divides the ad-
justment items into seven, camera adjustment 1-7. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Note 1: The Automatic Adjustment Program does not support the “Hall Adjustment” and “Wide Limit Adjustment”.
Note 2: Dark Siemens star chart.
Note 3: Use the AWB Adjustment Program (H5AwbAdjustment.exe).
Table 6-1-3
_
_
_
_
_
_
_
_
Button Name
Adjustment
Subject
Adjustment
Page
Adjustment
Address
(Note 1)
Hall Adj.
Not required
CE
54 to 57
(Note 1)
Wide Limit Adj.
Not required
6F
18, 19
CAMERA Adjustment 1
Flange Back Adj.
Siemens star chart with ND filter
for minipattern box (Note 2) or
Flange back adjustment jig
6D
A4 to AF, D0 to F7
6F
18 to 3F, 52, 53
CAMERA Adjustment 2
Flange Back Check
Siemens star
(1.0m from front the lens)
(Luminance: 200 to 400 lux)
F No. Compensation
6F
60 to 63, 6B to 6D
6F
6B, 6F
78
0C to 0F
Mechanical Shutter Adj.
6F
6B to 6D, B8 to BD,
C7 to C9
79
40 to 42, 45 to 47,
4A
Light Value Adj.
6F
65 to 67
(Note 3)
AWB 3200K-5800K
Standard Data Input
9 color chart
(Standard picture frame)
6E
00 to 21, 24 to 49
Color Reproduction
Adj. & Check
9 color chart
(Standard picture frame)
6E
50 to 57
CCD Linearity Check
CCD White Defect
Compensation Check
CCD Black Defect
Compensation Check
6E
72 to 75
6F
D8 to EF
CAMERA Adjustment 6
Auto Focus Illumination Check
Flash adjustment box (50 cm)
6F
10 to 15
CAMERA Adjustment 7
Angular Velocity Sensor
Sensitivity Adj.
Not required
CF
0C, 0D
Strobe Adj.
Flash adjustment box (50 cm)
CAMERA Adjustment 5
Measure Gain Adj.
CAMERA Adjustment 3
Clear chart
(Standard picture frame)
Clear chart
(Standard picture frame)
CAMERA Adjustment 4
6-16
DSC-H5_ADJ
1-4-3.
Adjusting Method
1.
Hall Adjustment
Perform this adjustment only when replacing the lens block. When
the microprocessor, circuit etc. is damaged, don't perform this adjust-
ment but check the operations only.
Adjustment Page
CE
Adjustment Address
54 to 57
1-1. Adjusting method when the lens is replaced:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
CE
54
Set the data. (Note)
4
CE
55
Set the data. (Note)
5
CE
56
Set the data. (Note)
6
CE
57
Set the data. (Note)
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
Note: The data of page: CE, address: 54 to 57, that are set in the
Orders 3 to 6 as described above, are shown on the data
sheet supplied with the replacement lens for repair.
Processing after Completing Adjustment:
Order Page Address
Data
Procedure
1
00
01
00
Set the data.
2
Check that the steady
shot operations have
been performed normally.
Fig. 6-1-18
Data for Page: CE, Address: 57
The right four digits of the seal (2-byte data)
Data for Page: CE, Address: 56
Y
 
XXXX
Data for Page: CE, Address: 55
The right four digits of the seal (2-byte data)
Data for Page: CE, Address: 54
P
 
XXXX
1-2. Adjusting method when replacement of lens is
not required and the SY-150 board is replaced:
When the data of page: CE, address: 54 to 57 can be
read from the defective SY-150 board before replace-
ment, and all of the data are not “00”:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
CE
54
Set the previous data
4
CE
55
Set the previous data
5
CE
56
Set the previous data
6
CE
57
Set the previous data
7
Save the data.
8
80
34
Check the data is “00”.
9
80
30
Check the data is “00”.
When the data of the page: CE, address: 54 to 57 can
be read out from the defective SY-150 board before
replacing it, and all of the data are “00”:
1) Replace the lens with the replacement lens and perform “1-1.
Adjusting method when the lens is replaced”.
When the data of page: CE, address: 54 to 57 cannot
be read from the defective SY-150 board:
1) Replace the lens with the replacement lens and perform “1-1.
Adjusting method when the lens is replaced”.
6-17
DSC-H5_ADJ
2.
Wide Limit Adjustment
Adjustment to remove variations at the wide end of the inner fo-
cus lens.
Adjustment Page
6F
Adjustment Address
18, 19
2-1. Adjusting method when the lens is replaced:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
6F
18
Set the data. (Note)
4
6F
19
Set the data. (Note)
5
7C
16
01 
t 00
Change the data.
(The data is OK if it is “00”.)
6
Save the data.
7
80
34
Check the data is “00”.
8
80
30
Check the data is “00”.
9
Perform “Flange Back
Adjustment”.
Note: The data of page: 6F, address: 18 and 19, that are set in the
Orders 3 and 4 as described above, are shown on the data
sheet supplied with the replacement lens for repair.
Set the upper single byte of the 2-byte data shown on the
sheet to address: 18, and the lower byte of the data to the
address: 19.
Fig. 6-1-19
2-2. Adjusting method when replacement of lens is
not required and the SY-150 board is replaced:
When the data of page: 6F, address: 18 and 19 can be
read from the defective SY-150 board before replace-
ment, and both of the data are not “00”:
Adjusting method:
Order Page Address
Data
Procedure
1
00
01
01
Set the data.
2
40
38
00
Set the data.
3
6F
18
Set the previous data
4
6F
19
Set the previous data
5
7C
16
01 
t 00
Change the data.
(The data is OK if it is “00”.)
6
Save the data.
7
80
34
Check the data is “00”.
8
80
30
Check the data is “00”.
9
Perform “Flange Back
Adjustment”.
When the data of the page: 6F, address: 18 and 19 can
be read out from the defective SY-150 board before
replacing it, and both of the data are “00”:
1) Replace the lens with the replacement lens and perform “2-1.
Adjusting method when the lens is replaced”.
When the data of page: 6F, address: 18 and 19 cannot
be read from the defective SY-150 board:
1) Replace the lens with the replacement lens and perform “2-1.
Adjusting method when the lens is replaced”.
Note: The data of page: 7C, address: 16, that is set in the Order 5
of the adjusting method of 2-1 or 2-2, is “01” when shipped
from the factory. Let the data remain “00” after completion
of the service adjustment.
Data for Page: 6F, Address: 19
The right four digits of the seal (2-byte data)
Data for Page: 6F, Address: 18
XX
 
XXXX
6-18
DSC-H5_ADJ
Preparation of Flange Back Adj.
(Using the flange back adjustment jig)
(Luminance: about 300 lux)
Note 3: 
When using the flange back adjustment jig, take care of
the following points:
• For the illumination, use a light source such as an in-
candescent lamp or inverter type fluorescent light free
from flickering.
• Do not make an adjustment in the environment where
fluorescent lamp flickering occurs even if the illumi-
nance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent
light at a place free from the influence of room illumi-
nation.
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
Note 4: Take care not to hit the flange back adjustment jig
when extending the lens.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-21
3.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
Preparation of Flange Back Adj.
(Using the minipattern box)
1) The minipattern box is installed as shown in the following fig-
ure.
Note 1: The attachment lenses are not used.
Note 2: Take care not to hit the mini-pattern box when ex-
tending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the
minipattern box.
Fig. 6-1-20
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
± 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
Page of 36
Display