DOWNLOAD Sony DAV-TZ215 / DAV-TZ715 / HBD-TZ215 / HBD-TZ715 Service Manual ↓ Size: 3.7 MB | Pages: 72 in PDF or view online for FREE

Model
DAV-TZ215 DAV-TZ715 HBD-TZ215 HBD-TZ715
Pages
72
Size
3.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Audio
File
dav-tz215-dav-tz715-hbd-tz215-hbd-tz715.pdf
Date

Sony DAV-TZ215 / DAV-TZ715 / HBD-TZ215 / HBD-TZ715 Service Manual ▷ View online

HBD-TZ215/TZ715
17
2-14.  DC  MOTOR (LOADING)  (M001),  MS-203  BOARD
2-15.  HOW  TO  BEND  WIRE (FLAT  TYPE)
2 three claws
6 MS-203 board
red
black
4 two solders
1  screw
 (M1.7 
u 2.5) 
3
5 DC motor (loading)
 (M001)
‡ZLUHIODWW\SHFRUHOHQJWKPP5HI1R
‡ZLUHIODWW\SHFRUHOHQJWKPP5HI1R
The upper side
is terminal side. 
The upper side
is terminal side. 
: Mountain fold
: Valley fold
198 mm
18 mm
25 mm
27 mm
FL board
(CN5005)
MAIN board
(CN506)
TUNER (FM)
MAIN board
(CN4000)
MAIN board
(CN1202)
MAIN board
(CN1101)
12 mm
‡ZLUHIODWW\SHFRUHOHQJWKPP5HI1R
‡IOH[LEOHIODWFDEOH3OHQJWKPP5HI1R
CDM85 (MB) assy
50 mm
13 ± 0.5 mm
optical pick-up
(KHM-313CAA)
The lower side
is terminal side. 
The lower side
is terminal side. 
The lower side
is terminal side. 
The lower side
is terminal side. 
12 mm
12 mm
The upper side
is terminal side. 
137 mm
10 mm
The upper side
is terminal side. 
HBD-TZ215/TZ715
18
SECTION  3
TEST  MODE
Note: Incorrect operations may be performed if the test mode is not 
entered properly.
 
In this case, press the [?/1] button to turn the power off, and 
retry to enter the test mode.
COLD  RESET
The cold reset clears all data including preset data stored in the 
RAM to initial conditions. Execute this mode when returning the 
unit to the customers.
Procedure:
1.  Press the [
?/1
] button to turn the power on. 
2.  Press three buttons [
N
], [FUNCTION] and [
?/1
] simultane-
ously.
3.  When this button is operated, display as “COLD RESET” for 
a while and all of the settings are reset. 
PANEL  TEST  MODE
This mode is used to check the software version, fl uorescent indi-
cator tube and keys.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  While pressing the [
x
] and the [
N
] buttons simultaneously, 
turn the [MASTER VOLUME] dial in the direction of (+).
3.  When the panel test mode is activated, all segments are turned 
on.
Releasing method :
While pressing the [
x
] and the [
N
] buttons simultaneously, turn 
the [MASTER VOLUME] dial in the direction of (+).
1.  Version test mode
This mode can confi rm the model name, destination and MC ver-
sion.
Procedure:
1.  When the panel test mode is activated, press the [FUNCTION] 
button and the model name is displayed, the version test mode 
is activated.
2.  Whenever the [FUNCTION] button is pressed, the display 
changes in the following order.
 
Model name t Destination t MC Version 
3.  Press the [REC TO USB] button when the MC version is on 
display. The date of software production is displayed.
4.  Press the [REC TO USB] button again and the version is dis-
played.
Releasing method :
While pressing the [
x
] and the [
N
] buttons simultaneously, turn 
the [MASTER VOLUME] dial in the direction of (+).
2.  FL pattern test mode
This mode can confi rm the pattern of fl uorescent indicator tube.
Procedure:
1.  When the panel test mode is activated, press the [
Z
] button, to 
select the FL pattern test mode. When the FL pattern test mode, 
half segments of fl uorescent indicator tube.
2. Press the [
Z
] button, half segments of fl uorescent  indicator 
tube.
3. Next 
press 
the 
[
Z
] button, all segments of fl uorescent indicator 
tube is turn on.
Releasing method :
While pressing the [
x
] and the [
N
] buttons simultaneously, turn 
the [MASTER VOLUME] dial in the direction of (+).
3.  Key test mode
This mode can confi rm the operation of keys.
Procedure:
1.  When the panel test mode is activated, press the [
?/1
] button, 
to select the key test mode.
2.  To enter the KEY test mode, the fl uorescent indicator displays 
“K0 V0”. Each time an another button is pressed, “KEY” value 
increases. However, once a button is pressed, it is no longer 
taken into account. When all keys are pressed correctly, “K6 
V0”/“OK V0” are displayed.
3.  When the [MASTER VOLUME] dial is turned in the direction 
of (+), “V0” is changed to “V1”, then ... “V9”.
 
When the [MASTER VOLUME] dial is turned in the direction 
of (–), “V0” is changed to “V9”, then ... “V1”.
Releasing method :
While pressing the [
x
] and the [
N
] buttons simultaneously, turn 
the [MASTER VOLUME] dial in the direction of (+).
DISC  TRAY  LOCK
The disc tray lock function for the antitheft of an demonstration 
disc in the store is equipped.
Procedure :
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set DVD/CD function.
3.  Insert a disc.
4. Press 
the 
[
x
] button and the [
Z
] button simultaneously for fi ve 
seconds.
5.  The message “LOCKED” is displayed and the tray is locked.
Releasing method :
1. Press 
the 
[
x
] button and the [
Z
] button simultaneously for fi ve 
seconds again.
2.  The message “UNLOCKED” is displayed and the tray is un-
locked.
Note: When “LOCKED” is displayed, the tray lock is not released by 
turning power on/off with the [?/1] button.
HBD-TZ215/TZ715
19
DVD  VERSION  DISPLAY
The STR and DVD microprocessor versions are displayed.
Procedure:
1.   Press the [
?/1
] button to turn the power on.
2.   Press the [
N
] button and the [
?/1
] button simultaneously for 
three seconds. SC version display is presented.
3.   Pressing the [FUNCTION] button presents a DV version dis-
play. Pressing the [FUNCTION] button again returns to the SC 
version display.
Releasing method :
Press any button other than the [FUNCTION] button.
PRODUCT  OUT
This mode moves the optical pick-up to the position durable to 
vibration and clears all data including preset data stored in the STR 
RAM to initial conditions. Use this mode when returning the unit 
to the customer after repair.
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set the function “DVD/CD”.
3.  Remove all discs.
4.  While pressing the [
x
] and the [
Z
] buttons simultaneously, 
turn the [MASTER VOLUME] dial in the direction of (+).
5.  Displayed to message “SERVICE IN” on the fl uorescent indi-
cator tube when pressing in turn the [4] 
t [DVD MENU] t 
[CLEAR] buttons on the remote commander.
6.  After the “STANDBY” blinking display fi nishes, the message  
“MECHA LOCK” 
h “UNPLUG” is displayed on the fl uo-
rescent indicator tube disconnect the AC power plug, then the 
product out mode is set.
 
The STR RAM initialization is executed upon a next power-on 
after the power is turned off.
COLOR  SYSTEM  CHANGE (Middle East, African and 
Indian models only)
Color system change to video signal format (NTSC/PAL).
Procedure:
1.  Press the [
?/1
] button to turn the power on.
2.  Press the [FUNCTION] button to set the function “DVD/CD”.
3.  Press the [
?/1
] button to turn the set OFF. 
4.  Press two buttons [FUNCTION] and [
?/1
] simultaneously, 
and the display of fl uorescent indicator tube changes to “COL-
OR PAL” or “COLOR NTSC”.
PROTECTION  FACTOR (SD  DETECTION/DC  DETEC-
TION/TSD  DETECTION) IDENTIFICATION  TEST  MODE
When an error is detected, the fl uorescent indicator tube alternately 
displays “PROTECTOR” 
h “PUSH POWER”.
    
r
  Press the [
?/1
] button.
 
* Buttons other than the [
?/1
] button are invalid.
“STANDBY” blinks three times on the fl uorescent indicator tube.
    
r
The protection release state (POWER OFF) is established.
(No fl uorescent indicator tube display) 
    
r  Press the [
?/1
] button two times.
The power to the system turns on, and the normal operation is 
established. (Restore) 
During the protection state: 
1.   If the AC plug is connected or disconnected during the protec-
tion state, the protection state is released, and the normal op-
eration is established. (The protection state is not maintained.) 
2.   The protection factor is displayed by pressing the [RETURN] 
t [3] t [2] t [0] t [0] t [ANGLE] buttons of the re-
mote commander.
 
(during the “PROTECTOR” 
h “PUSH POWER” display).
 
k  When SD is detected: Repeats
   “SD 
DETECT” 
h “PROTECTOR”.
 
k  When DC is detected: Repeats 
   “DC 
DETECT” 
h “PROTECTOR”.
 
k  When TSD is detected: Repeats 
   “TMP 
DETECT” 
h “PROTECTOR”.
PL:  SD detection
 
When the “L” output from the SD (shutdown) port on the 
S-MASTER POWER Driver Shutdown and voltage descent 
(15V or less) of 26V power supply (PVDD) are detected.
 DC 
detection
 
When the “L” output from the power/speaker error detection 
circuit (DC detection port) is detected for two seconds con-
tinually, the power system other than that of the fl uorescent 
indicator tube is turned off, and the protection state is estab-
lished.
 TSD 
detection
 
When the “L” output from the thermal shutdown port 
(TSDM) on the motor driver is detected.
DVD  SECTION
GENERAL  DESCRIPTION
The IOP measurement allows you to make diagnosis and adjust-
ment simply by using the remote commander and monitor TV. The 
instructions, diagnosis results, etc. are given on the on-screen dis-
play (OSD).
Be sure to execute the IOP measurement when a BU (Base Unit) 
is replaced.
HOW  TO  ENTER  TEST  MODE
While pressing the [
x
] and the [
Z
] buttons simultaneously, turn 
the [MASTER VOLUME] dial in the direction of (+) with the 
DVD player in power on.
The test mode starts, displayed “SERVICE IN” on this model 
display then the menu shown below will be displayed on the TV 
screen.
*  The display of the “Model Name” of the “Remocon Diagnosis 
Menu” change with the model and the destination.
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
5. USB Test Mode Setting
Model Name
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
: XXXX_XXXX
The menu above is the Remocon Diagnosis Menu screen which 
consists of fi ve main functions. At the bottom of the menu screen, 
the model name and IF-con version.
Releasing method :
Press the [
?/1
] button on the remote commander.
HBD-TZ215/TZ715
20
1.  Executing IOP measurement
In order to execute IOP measurement, the following standard pro-
cedures must be followed.
Procedure:
1.  In power on, while pressing the [
x
] and the [
Z
] buttons simul-
taneously, turn the [MASTER VOLUME] dial in the direction 
of (+).
 
Remocon Diagnosis Menu
0. External Chip Check
1. Servo Parameter Check
2. Drive Manual Operation
3. Emergency History
4. Version Information
IF-con
: Ver. XX.XX (XXXX)
Syscon
: Ver. X.XXX
5. USB Test Mode Setting
Model Name : XXXX_XXXX
2.  Select “2. Drive Manual Operation” by pressing the [2] button 
on the remote commander. The screen will appear as shown.
 
Drive Manual Operation
1. Servo Control
2. Track/Layer Jump
3. Manual Adjustment
4. Tray Aging Mode
5. MIRR time adjust
0. Return to Top Menu
3.  Select “3. Manual Adjustment” by pressing the [3] button on 
the remote commander. The screen will appear as shown.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
O o  Change Value
[RETURN] Return to previous menu
4. 
Select “6. IOP” by pressing the [6] button on the remote com-
mander.
5.  Wait until a hexadecimal number appear.
 
Manual Adjust
1. Track Balance Adjust:
2. Track Gain Adjust:
3. Focus Balance Adjust:
4. Focus Gain Adjust:
5. Eq Boost Adjust:
6. Iop. 47:
7. TRV. Level:
8. S curve(FE) Level:
9. RFL(PI) Level:
0. MIRR Time:
[RETURN] Return to previous menu
O o  Change Value
6. 
Convert each data from hexadecimal to decimal using conver-
sion table.
7. Please 
fi nd the label on the rear of the BU (Base Unit).
 
The default IOP value is written in the label.
8.  Subtract between these two values.
9.  If the remainder is smaller than 93 (decimal), then it is OK. 
However if the value is higher than 93, then the BU is defec-
tive and need to be change.
10.  Press the [RETURN] button on the remote commander to re-
turn back to previous menu.
11.  Press the [0] button on the remote commander to return to Top 
Menu.
2. Emergency 
history
To check the emergency history, please follow the following pro-
cedure.
Procedure:
1.  From the Top Menu of Remocon Diagnosis Menu, select “3. 
Emergency History Check” by pressing the [3] button on the 
remote commander. The following screen appears on the on-
screen display.
 
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
*
1
*
2
*
3
2.  You can check the total time when the laser is turned on during 
playback of DVD and CD from the above menu. The maxi-
mum time, which can be displayed are 999h 59min.
3.  You can check the error code of latest 10 emergency history 
from the above menu. To view the previous or next page of 
emergency history, press [
.
] or [
>
] button on the remote 
commander. The error code consists of the following three 
blocks. The fi rst block indicates the error code. The second 
block indicates the parameter and the third block indicates the 
time of error code as shown below.
• Error Code
 
Emg. History Check
01.  01  05  04  04
Laser Hours
CD
999h
59min
DVD
999h
59min
00  92  46  00
00  00  00  00
00  00  23  45
02.  02  02  01  01
00  A9  4B  00
00  00  00  00
00  00  23  45
 
[Next]   Next Page    [Prev]  Prev Page
[O]  Return to Top Menu
 
*1 : Error Code
 
*2 : Parameter of error code
 
*3 : Time of error code
Page of 72
Display